Tony Linwei Chen

Dr. Tony Linwei Chen

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2025 in Journal of Biomechanics
Verified
Journal Article
Closed access
GZGuoxin Zhang
Guoxin Zhang
TCTony Linwei Chen
Tony Linwei Chen
LWLinjuan WEI
Linjuan WEI
FBFangbo Bing
Fangbo Bing
HCHejin Cai
Hejin Cai
MZMing Zhang
Ming Zhang

22 May 2025 in Journal of Science and Medicine in Sport
Verified
Journal Article
Closed access
GZGuoxin Zhang
Guoxin Zhang
YFYihao Fu
Yihao Fu
LWLinjuan Wei
Linjuan Wei
FBFangbo Bing
Fangbo Bing
HCHejin Cai
Hejin Cai
MZMing Zhang
Ming Zhang

16 March 2026 in Frontiers in Sports and Active Living
Verified
Journal Article
Open access
PDF file
YWYichen Wang
Yichen Wang
WHWei Huang
Wei Huang
NZNan Zhang
Nan Zhang
TCTony Linwei Chen
Tony Linwei Chen
MZMing Zhang
Ming Zhang
Introduction: Wrapping closure systems are alternative footwear lacing methods that could influence perceived fit and movement biomechanics, yet their performance during prolonged running and impacts on muscle activities remain underexplored. This study compared the effects of a wrapping closure system (dial-based lacing system, DLS) and conventional laces (CL) on wearing comfort, lock-in stability, running kinematics, and lower-limb muscle activation in trained marathoners during an extended running session. Methods: Twenty marathoners completed two 50-minute treadmill running trials on separate days using either DLS or CL. Wearing comfort was indicated by donning/doffing time and repeated VAS ratings. Lock-in stability was evaluated via dorsal foot pressure measures, shoe-throat width, and incidence of lace loosening. Running kinematics were assessed by motion capture and musculoskeletal modeling. Surface EMG was recorded from four lower-leg muscles. Between-group differences were examined statistically. Results: DLS produced shorter donning/doffing time and lower discomfort ratings during the mid-to-late running stage compared to CL ( p < 0.025). There was no incidence of lace loosening in DLS while that of CL was 10% ( p = 0.500). Pressure fluctuations and peak tibialis anterior activation were significantly smaller in DLS than CL ( p < 0.036) at several time checkpoints of the running trials. No significant differences were observed in other kinematic and EMG measures. Conclusion: DLS demonstrated greater wearing comfort than CL. DLS also reduced variability in dorsal foot pressure and lowered local muscular demand without altering overall running kinematics, which indicates the potential advantage of DLS in maintaining foot–shoe coupling during endurance running.