Jianqun Cheng

Prof. Jianqun Cheng

IC, Quanzhou University of Information Engineering, Quanzhou, Fujian, China
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2023 in ACS Nano
Verified
Journal Article
Open access
TLTiezhu Liu
Tiezhu Liu
GGGuang-Yang Gou
Guang-Yang Gou
FGFupeng Gao
Fupeng Gao
PYPan Yao
Pan Yao
HWHaoyu Wu
Haoyu Wu
Ning XueNing Xue
Ning Xue
Pressure sensors with high sensitivity, a wide linear range, and a quick response time are critical for building an intelligent disease diagnosis system that directly detects and recognizes pulse signals for medical and health applications. However, conventional pressure sensors have limited sensitivity and nonideal response ranges. We proposed a multichannel flexible pulse perception array based on polyimide/multiwalled carbon nanotube-polydimethylsiloxane nanocomposite/polyimide (PI/MPN/PI) sandwich-structure pressure sensor that can be applied for remote disease diagnosis. Furthermore, we established a mechanical model at the molecular level and guided the preparation of MPN. At the structural level, we achieved high sensitivity (35.02 kPa-1) and a broad response range (0-18 kPa) based on a pyramid-like bilayer microstructure with different upper and lower surfaces. A 27-channel (3 × 9) high-density sensor array was integrated at the device level, which can extract the spatial and temporal distribution information on a pulse. Furthermore, two intelligent algorithms were developed for extracting six-dimensional pulse information and automatic pulse recognition (the recognition rate reaches 97.8%). The results indicate that intelligent disease diagnosis systems have great potential applications in wearable healthcare devices.

26 April 2023 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
TLTiezhu Liu
Tiezhu Liu
LLLidan Liu
Lidan Liu
GGGuang-Yang Gou
Guang-Yang Gou
ZFZhen Fang
Zhen Fang
JSJianhai Sun
Jianhai Sun
NXNing Xue
Ning Xue

30 September 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
JCJianqun Cheng
Jianqun Cheng
NXNing Xue
Ning Xue
WZWenyi Zhou
Wenyi Zhou
BQBoqi Qin
Boqi Qin
BQBocang Qiu
Bocang Qiu
XSXuguang Sun
Xuguang Sun
Flexible and wearable sensors have emerged as transformative technologies in the field of real-time health monitoring, offering non-invasive, continuous, and personalized healthcare solutions. These devices are designed to conform intimately to the human body, enabling seamless detection of vital physiological and biochemical signals under dynamic conditions. Recent advancements in material science and device engineering have led to the development of sensors with enhanced sensitivity, biocompatibility, and wearability, addressing the growing demand for preventive healthcare and remote patient monitoring. This review provides a comprehensive overview of the progress in flexible wearable sensors, including novel materials, sensor designs, and system integration strategies. It begins by surveying the latest advances in substrate and functional materials and hybrid structures that enable mechanical flexibility, skin conformability, and high sensitivity. The review then examines various sensor mechanisms and their implementation in monitoring vital signs, physical activity, and chronic diseases. Real-world applications are explored in depth, covering scenarios from cardiovascular and respiratory monitoring to motion tracking and rehabilitation support. Despite the significant strides made, challenges related to material robustness, sensor accuracy, and multi-modal integration remain, and this review discusses these challenges alongside potential future directions for enhancing the functionality and adoption of flexible wearable sensor systems.

31 May 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
JCJianqun Cheng
Jianqun Cheng
NXNing Xue
Ning Xue
BQBocang Qiu
Bocang Qiu
BQBoqi Qin
Boqi Qin
QZQingchun Zhao
Qingchun Zhao
XSXuguang Sun
Xuguang Sun
Micro-electro-mechanical system (MEMS) electromagnetic actuators have rapidly evolved into critical components of various microscale applications, offering significant advantages including precision, controllability, high force density, and rapid responsiveness. Recent advancements in actuator design, fabrication methodologies, smart control integration, and emerging application domains have significantly broadened their capabilities and practical applications. This comprehensive review systematically analyzes the recent developments in MEMS electromagnetic actuators, highlighting core operating principles such as Lorentz force and magnetic attraction/repulsion mechanisms and examining state-of-the-art fabrication technologies, such as advanced microfabrication techniques, additive manufacturing, and innovative material applications. Additionally, we provide an in-depth discussion on recent enhancements in actuator performance through smart and adaptive integration strategies, focusing on improved reliability, accuracy, and dynamic responsiveness. Emerging application fields, particularly micro-optical systems, microrobotics, precision micromanipulation, and microfluidic components, are extensively explored, demonstrating how recent innovations have significantly impacted these sectors. Finally, critical challenges, including miniaturization constraints, integration complexities, power efficiency, and reliability issues, are identified, alongside a prospective outlook outlining promising future research directions. This review aims to serve as an authoritative resource, fostering further innovation and technological advancement in MEMS actuators and related interdisciplinary fields.

17 January 2023 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
LZLichao Zhang
Lichao Zhang
KWKaifeng Wang
Kaifeng Wang
JCJiamin Chen
Jiamin Chen
TMTianjun Ma
Tianjun Ma
WLWangzhe Li
Wangzhe Li
Ning XueNing Xue
Ning Xue
The integration density of photonic integrated circuits (PICs) is significantly limited by the waveguide bend losses. Reducing waveguide losses by design of the geometry of waveguide bends is important for photonic integrated circuits. Currently, circular bend and Euler bend are the two most common bends used in bending waveguide designs. A modified n -adjustable bend is proposed for ultra-small radius (≤2 µm) by applying the widening width method to n -adjustable bends. Simulations and experiments indicate that the modified n -adjustable bends show excellent performances in bend loss when the radius is 0.5, 1.0, 1.5, and 2.0 µm. In the experiments, the reduction of measured bend loss was from 0.8197 dB/90° (Euler bend) to 0.0689 dB/90° (modified n -adjustable bend) when radius equals 1.0 μm, and from 0.1438 dB/90° (Euler bend) to 0.0167 dB/90° (modified n -adjustable bend) when radius equals 2.0 μm. The modified n -adjustable bends are potential candidates for waveguide components in ultra-compact photonic integrated circuits.

9 February 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
YGYusen Guo
Yusen Guo
GGGuangyang Gou
Guangyang Gou
PYPan Yao
Pan Yao
FGFupeng Gao
Fupeng Gao
TMTianjun Ma
Tianjun Ma
Ning XueNing Xue
Ning Xue
Deep learning (DL) has been used for electromyographic (EMG) signal recognition and achieved high accuracy for multiple classification tasks. However, implementation in resource-constrained prostheses and human-computer interaction devices remains challenging. To overcome these problems, this paper implemented a low-power system for EMG gesture and force level recognition using Zynq architecture. Firstly, a lightweight network model structure was proposed by Ultra-lightweight depth separable convolution (UL-DSC) and channel attention-global average pooling (CA-GAP) to reduce the computational complexity while maintaining accuracy. A wearable EMG acquisition device for real-time data acquisition was subsequently developed with size of 36mm×28mm×4mm. Finally, a highly parallelized dedicated hardware accelerator architecture was designed for inference computation. 18 gestures were tested, including force levels from 22 healthy subjects. The results indicate that the average accuracy rate was 94.92% for a model with 5.0k parameters and a size of 0.026MB. Specifically, the average recognition accuracy for static and force-level gestures was 98.47% and 89.92%, respectively. The proposed hardware accelerator architecture was deployed with 8-bit precision, a single-frame signal inference time of 41.9μs, a power consumption of 0.317W, and a data throughput of 78.6 GOP/s.