Electricity market reforms and decreasing technology costs have propelled residential solar PV growth leading distribution network operators to face operational challenges including reverse power flows and voltage regulation during peak solar generation. Traditional mono-facial south-facing PV systems concentrate production at midday when demand may be low, leading to high curtailment, especially for downstream households. This study proposes vertically installed east–west-facing bifacial PV systems (BiE and BiW), characterized by two energy peaks (morning and evening), which are better aligned with residential demand and alleviate grid constraints. Using load flow simulations, the performance of vertical bifacial configurations was compared against mono-facial systems across PV capacities from 1 to 20 kW. Fairness in curtailment was evaluated at 10 kW using Jain’s fairness index, the Gini index, and the Curtailment index. Simulation results show that BiE and BiW installations, especially at higher capacities, not only generate more energy but also are better at managing curtailment. At 10 kW, BiE and BiW increased bid energies by 815 kWh and 787 kWh, and reduced curtailed energy by 1566 kWh and 1499 kWh, respectively. These findings highlight the potential of bifacial PV installations in mitigating curtailment and improving fairness in energy distribution, supporting the demand for residential PV systems.
Electricity market reforms and decreasing technology costs have propelled residential solar PV growth leading distribution network operators to face operational challenges including reverse power flows and voltage regulation during peak solar generation. Traditional mono-facial south-facing PV systems concentrate production at midday when demand may be low, leading to high curtailment, especially for downstream households. This study proposes vertically installed east-west-facing bifacial PV systems (BiE and BiW), characterized by two energy peaks (morning and evening) which are better aligned with residential demand and alleviate grid constraints. Using load flow simulations, the performance of vertical bifacial configurations was compared against mono-facial systems across PV capacities from 1 to 20 kW. Fairness in curtailment was evaluated at 10 kW using Jain’s Fairness Index, Gini Index, and Curtailment Index. Simulation results show that BiE and BiW installations, especially at higher capacities, not only generate more energy but also are better at managing curtailment. At 10 kW, BiE and BiW increased bid energies by 815 kWh and 787 kWh, and reduced curtailed energy by 1566 kWh and 1499 kWh, respectively. These findings highlight the potential of bifacial PV installations in mitigating curtailment and improving fairness in energy distribution, supporting the demand for residential PV systems.
The rapid growth of PV generation in the distribution grid has necessitated PV curtailment to prevent overvoltage violations, and this has raised fairness issues as some are curtailed disproportionately to others. This paper proposes an adaptive PV curtailment scheme that balances fairness with energy sales using a Curtailment Index (CI) employed to reallocate curtailed energy between PV systems. The CI-based approach dynamically adapts each inverter’s output in real time to provide voltage compliance while ensuring that no individual PV system experiences an overburden of curtailment. The method is evaluated through MATLAB simulations on a three-PV test distribution network and validated experimentally on the PAGLIA ORBA solar microgrid, where its performance is compared to equal-curtailment and unfair strategies. The findings indicate that the adaptive method helps integrate high PV penetration more equitably and efficiently, ensuring stable grid operation while minimizing financial losses for PV owners.