Microfluidic devices offer well-defined physical environments that are suitable for effective cell seeding and in vitro three-dimensional (3D) cell culture experiments. These platforms have been employed to model in vivo conditions for studying mechanical forces, cell–extracellular matrix (ECM) interactions, and to elucidate transport mechanisms in 3D tissue-like structures, such as tumor and lymph node organoids. Studies have shown that fluid flow behavior in microfluidic slides (µ-slides) directly influences shear stress, which has emerged as a key factor affecting cell proliferation and differentiation. This study investigates fluid flow in the porous channel of a µ-slide using computational fluid dynamics (CFD) techniques to analyze the impact of perfusion flow rate and porous properties on resulting shear stresses. The model of the µ-slide filled with a permeable biomaterial is considered. Porous media fluid flow in the channel is characterized by adding a momentum loss term to the standard Navier–Stokes equations, with a physiological range of permeability values. Numerical simulations are conducted to obtain data and contour plots of the filtration velocity and flow-induced shear stress distributions within the device channel. The filtration flow is subsequently measured by performing protein perfusions into the slide embedded with native human-derived ECM, while the flow rate is controlled using a syringe pump. The relationships between inlet flow rate and shear stress, as well as filtration flow and ECM permeability, are analyzed. The findings provide insights into the impact of shear stress, informing the optimization of perfusion conditions for studying tissues and cells under fluid flow.
This study examines the impact of vocal fold (VF) lesions located on the superior surface on glottal airflow dynamics and tissue oscillatory behaviors using biomechanical simulations of a two-layered realistic VF model. It is hypothesized that morphological changes in the VFs due to the presence of a lesion cause changes in tissue elasticity and rheological properties, contributing to dysphonia. Previous research has lacked the integration of lesions in computational simulations of anatomically accurate larynx-VF models to explore their effects on phonation and contribution to voice disorders. Addressing the current gap in literature, this paper considers a computational model of a two-layered VF structure incorporating a lesion that represents a hemorrhagic polyp. A three-dimensional, subject-specific, multilayered geometry of VFs is constructed based on STL files derived from a human larynx CT scan, and a fluid–structure interaction (FSI) methodology is employed to simulate the coupling of glottal airflow and VF tissue dynamics. To evaluate the effects of the lesion’s presence, two FSI models, one with a lesion embedded in the cover layer and one without, are simulated and compared. Analysis of airflow dynamics and tissue vibrational patterns between these two models is used to determine the impact of the lesion on the biomechanical characteristics of phonation. The polyp is found to slightly increase airflow resistance through the glottis and disrupt vibratory symmetry by decreasing the vibration frequency of the affected fold, leading to weaker and less rhythmic oscillations. The results also indicate that the lesion increases tissue stress in the affected fold, which agrees with clinical observations. While quantitative ranges depend on lesion size and tissue properties, these consistent and physically meaningful trends highlight the biomechanical mechanisms by which lesions influence phonation.