This paper reports on the failure of cells with lithium iron phosphate (LFP) chemistry tested under a range of conditions to understand their effect on the volume and composition of gas generated. Cells of the following formats, 26,650, pouch, and prismatic, and capacities ranging from 3 to 230 Ah, were subjected to external heat, overcharge, and nail penetration tests. Gas volume was calculated, and the following gases analysed: H2, CO2, CO, CH4, C2H4, C2H6, C3H6, and C3H8. Cells that failed via external heating under inert conditions (N2 or Ar atmosphere) at 100% state of charge (SoC) typically generated 0.7 L/Ah of gas; overcharged cells, 0.11–0.68 L/Ah; and nail penetration between 0.3 and 0.5 L/Ah. In general, for all test configurations, regardless of atmosphere, the total gas volume contained a 40% concentration of H2, 15% of CO2, and the remaining gas consisted of varying concentrations of CO and flammable hydrocarbons. This demonstrates that despite differences in gas volume, the failure gas composition of LFP cells remains similar.