Methemoglobinemia (MetHb, Fe3+) is a chronic disease arising from the unequal distribution of oxyhemoglobin (HbFe2+, OHb) in the blood circulatory system. The oxidation of standard oxyhemoglobin forms methemoglobin, causing cyanosis (skin bluish staining). Methemoglobin cannot bind the pulmonary gaseous ligands such as oxygen (O2) and carbon monoxide (CO). As an oxidizing agent, the biochemical approach (MetHb, Fe3+) is modified in vitro by sodium nitrite (NaNO2). The silver-doped iron zinc oxide (Ag@Fe3O4/ZnO) is hydrothermally synthesized and characterized by analytical and spectroscopic techniques for the electrochemical sensing of methemoglobin via cyclic voltammetry (CV). Detection parameters such as concentration, pH, scan rate, electrochemical active surface area (ECSA), and electrochemical impedance spectroscopy (EIS) are optimized. The linear limit of detection for Ag@Fe3O4/ZnO is 0.17 µM. The stability is determined by 100 cycles of CV and chronoamperometry for 40 h. The serum samples of anemia patients with different hemoglobin levels (Hb) are analyzed using Ag@Fe3O4/ZnO modified biosensor. The sensor's stability, selectivity, and response suggest its use in methemoglobinemia monitoring.
Liver cancer is globally the most frequent fatal malignancy, and its identification is critical for making clinical decisions about treatment options. Pathological diagnostics and contemporary imaging technologies provide insufficient information for tumor identification. Hydrogen peroxide (H2O2), an emerging biomarker is a powerful oxidant found in the tumor microenvironment, and stimulates the invasion, proliferation, and metastasis of liver cancer cells. This study describes a medically effective and sensitive electrochemical sensor based on ascorbic acid immobilized zinc selenide nanoparticles (AsA@Zn-Se NPs) decorated on a glassy carbon electrode (GCE) for determining H2O2 in PBS and human serum samples of liver cancer patients. The morphological and structural characterization of fabricated sensor is done by Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), ultraviolet-visible (UV-Vis) spectroscopy, energy dispersive X-ray (EDX), and scanning electron microscopy (SEM). Ascorbic acid (AsA), an antioxidant for H2O2 redox behavior, is immobilized on Zn-Se NPs to aid H2O2 detection through cyclic voltammetry (CV). The sensor exhibits a low detection limit, and board linear range of 0.49 µM and 0–70 µM, respectively. The low-cost electrochemical sensor is robust for up to 100 cycles. Elecys AFP assay results validate that increasing alpha-fetoprotein (AFP) concentration, a biomarker for liver cancer, can increase the H2O2 levels in serum samples. Therefore, the proposed sensor can be used to diagnose liver cancer in clinical settings.
1
3 March 2025 in Applied Microbiology and Biotechnology
Liver cirrhosis is a life-threatening disorder characterized by severe hepatitis C. Early detection of hepatitis C is crucial since HCV infection has few symptoms, and the patient may remain unaware for many years. The early-stage detection can assist in the treatment and prevent further virus transmission. Abnormally varying albumin concentrations in hepatitis C patients can lead to hypoalbuminemia. Herein, a novel Co-Ni/TiO2 core–shell-based electrochemical sensor is developed for facile and ultra-sensitive human serum albumin (HSA) detection in HCV patients. Co-Ni/TiO2 core shells are fabricated via coprecipitation and hydrothermal methods and used for non-enzymatic detection albumin with high sensitivity, selectivity, and lower detection limits. Cyclic voltammetry, chronoamperometry (CA), and electrochemical impedance spectroscopy (EIS) is performed for albumin detection via Co-Ni/TiO2 modified GCE at different scan rates, pH, and concentrations. The linear range and limit of detection (LOD) obtained for the Co-Ni/TiO2 electrode are 0–30 μM and 0.019 μM, respectively. The utility of Co-Ni/TiO2 electrodes is extended to HSA sensing from HCV-infected patients. Albumin recovery at room temperature ranged from 81.0% to 91.3% in diluted human serum samples. The developed electrochemical analysis method is superior for HSA detection and can be a tool for clinical diagnosis in the future.
A novel electrochemical sensor based on multi-walled carbon nanotubes doped with vanadium pentoxide/telluride (MWCNTs@V2O5/Te) was developed for the detection and quantification of morphine sulfate in real biological samples. MWCNTs@V2O5/Te nanocomposite was functionalized with cysteamine as a linker, to create thiol interaction with the -OH group of the MWCNTs@V2O5/Te nanocomposite at one end, and free -NH2 group interaction with the -OH group on morphine sulfate, on the other end. This modification enhances the conjugation capability of morphine sulfate with the fabricated biosensor. (MWCNTs@V2O5/Te-Cys/GCE). MWCNTs@V2O5/Te nanocomposite morphological and structural analysis is carried out by SEM, TEM, EDX, FTIR, and UV-Vis spectroscopy. At varying concentrations and pH levels, the electrochemical sensor response of the modified electrode is investigated using cyclic voltammetry (CV). To validate the findings, differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS), and chronoamperometry are employed to investigate morphine sulfate detection, yielding excellent results in real biological samples. The fabricated sensor, as indicated by the calibration curve, exhibits a wide linear range of 10–60 µM and a limit of detection (LOD) of 0.01 µM by DPV. These results reveal that this novel sensor is highly stable, sensitive, and reproducible for detecting morphine sulfate. Therefore, this developed sensing platform can be used in clinical diagnostics, narcotics detection, and forensic analysis.
8 June 2026 in Nanomedicine: Nanotechnology, Biology and Medicine
Therapeutic drug monitoring (TDM) is very crucial for improving treatment outcomes because anti-cancer drugs have narrow therapeutic windows and their effects vary from individual to individual. Traditional analytical techniques are hampered by their high cost and limited suitability for rapid or point-of-care analysis, regardless of their sensitivity. This review discusses a nanomaterial-enhanced electrochemical sensing framework for the highly selective and sensitive detection of anti-cancer drugs in biological fluids. The engineered electrodes exhibit enhanced electron-transfer kinetics, increased surface reactivity, and improved antifouling properties by integrating carbon nanomaterials, metal/metal oxide nanoparticles, and ionic liquids. Characteristics like broad linear ranges, remarkable stability, and ultralow detection limit enable the accurate measurement of drugs including dasatinib (DAS), flutamide (FLUT), thiopurines, and doxorubicin (DOX). High recovery and minimal sample preparation are demonstrated by real sample analysis in serum and urine. Overall, this study emphasizes the revolutionary potential of nanomaterial-enhanced electrochemical sensors as beneficial, versatile platforms for TDM.