James W. Dias

Dr. James W. Dias

Otolaryngology - Head and Neck Surgery, Medical University of South Carolina, Charleston, Illinois, USA
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2016 in Journal of Cognitive Psychology
Verified
Journal Article
Closed access
LRLawrence Rosenblum
Lawrence Rosenblum
James W. DiasJames W. Dias
James W. Dias
JDJosh Dorsi
Josh Dorsi
The perceptual brain is designed around multisensory input. Areas once thought dedicated to a single sense are now known to work with multiple senses. It has been argued that the multisensory nature of the brain reflects a cortical architecture for which task, rather than sensory system, is the primary design principle. This supramodal thesis is supported by recent research on human echolocation and multisensory speech perception. In this review, we discuss the behavioural implications of a supramodal architecture, especially as they pertain to auditory perception. We suggest that the architecture implies a degree of perceptual parity between the senses and that cross-sensory integration occurs early and completely. We also argue that a supramodal architecture implies that perceptual experience can be shared across modalities and that this sharing should occur even without bimodal experience. We finish by briefly suggesting areas of future research.

11 September 2015 in Attention, Perception, & Psychophysics
Verified
Journal Article
Closed access
PDF file
James W. DiasJames W. Dias
James W. Dias
LRLawrence D. Rosenblum
Lawrence D. Rosenblum

1 March 2018 in Journal of Neurophysiology
Verified
Journal Article
Open access
PDF file
KHKelly C. Harris
Kelly C. Harris
KVKenneth Vaden
Kenneth Vaden
CMCarolyn M. McClaskey
Carolyn M. McClaskey
James W. DiasJames W. Dias
James W. Dias
JDJudy R. Dubno
Judy R. Dubno
Declines in auditory nerve (AN) function contribute to suprathreshold auditory processing and communication deficits in individuals with normal hearing, hearing loss, hyperacusis, and tinnitus. Procedures to characterize AN loss or dysfunction in humans are limited. We report several novel complementary metrics using the compound action potential (CAP), a direct measure of summated AN activity. Together, these metrics may be used to characterize AN function noninvasively in humans. We examined how these metrics change with stimulus intensity and interpreted these changes within a framework of known physiological properties of the basilar membrane and AN. Our results reveal how neural synchrony and the recruitment of AN fibers with longer first-spike latencies likely contribute to the CAP, affect auditory processing, and differ with noise exposure history in younger adults with normal pure-tone thresholds. Moving forward, this new battery of metrics provides a crucial step toward new diagnostics of AN function in humans. NEW & NOTEWORTHY Loss or inactivity of auditory nerve (AN) fibers is thought to contribute to suprathreshold auditory processing deficits, but evidence-based methods to assess these effects are not available. We describe several novel metrics that together may be used to quantify neural synchrony and characterize AN function in humans.

1 June 2021 in Psychology and Aging
Verified
Journal Article
Closed access
James W. DiasJames W. Dias
James W. Dias
CMCarolyn M. McClaskey
Carolyn M. McClaskey
KHKelly C. Harris
Kelly C. Harris
Multisensory input can improve perception of ambiguous unisensory information. For example, speech heard in noise can be more accurately identified when listeners see a speaker's articulating face. Importantly, these multisensory effects can be superadditive to listeners' ability to process unisensory speech, such that audiovisual speech identification is better than the sum of auditory-only and visual-only speech identification. Age-related declines in auditory and visual speech perception have been hypothesized to be concomitant with stronger cross-sensory influences on audiovisual speech identification, but little evidence exists to support this. Currently, studies do not account for the multisensory superadditive benefit of auditory-visual input in their metrics of the auditory or visual influence on audiovisual speech perception. Here we treat multisensory superadditivity as independent from unisensory auditory and visual processing. In the current investigation, older and younger adults identified auditory, visual, and audiovisual speech in noisy listening conditions. Performance across these conditions was used to compute conventional metrics of the auditory and visual influence on audiovisual speech identification and a metric of auditory-visual superadditivity. Consistent with past work, auditory and visual speech identification declined with age, audiovisual speech identification was preserved, and no age-related differences in the auditory or visual influence on audiovisual speech identification were observed. However, we found that auditory-visual superadditivity improved with age. The novel findings suggest that multisensory superadditivity is independent of unisensory processing. As auditory and visual speech identification decline with age, compensatory changes in multisensory superadditivity may preserve audiovisual speech identification in older adults. (PsycInfo Database Record (c) 2021 APA, all rights reserved).

26 April 2024 in Hearing Research
Verified
Journal Article
Closed access
James W. DiasJames W. Dias
James W. Dias
CMCarolyn M. McClaskey
Carolyn M. McClaskey
AAApril P. Alvey
April P. Alvey
ALAbigail Lawson
Abigail Lawson
LMLois J. Matthews
Lois J. Matthews
KHKelly C. Harris
Kelly C. Harris

19 September 2018 in Journal of Speech, Language, and Hearing Research
Verified
Journal Article
Open access
PDF file
CMCarolyn M. McClaskey
Carolyn M. McClaskey
James W. DiasJames W. Dias
James W. Dias
JDJudy R. Dubno
Judy R. Dubno
KHKelly C. Harris
Kelly C. Harris
Purpose Human auditory nerve (AN) activity estimated from the amplitude of the first prominent negative peak (N1) of the compound action potential (CAP) is typically quantified using either a peak-to-peak measurement or a baseline-corrected measurement. However, the reliability of these 2 common measurement techniques has not been evaluated but is often assumed to be relatively poor, especially for older adults. To address this question, the current study (a) compared test–retest reliability of these 2 methods and (b) tested the extent to which measurement type affected the relationship between N1 amplitude and experimental factors related to the stimulus (higher and lower intensity levels) and participants (younger and older adults). Method Click-evoked CAPs were recorded in 24 younger (aged 18–30 years) and 20 older (aged 55–85 years) adults with clinically normal audiograms up to 3000 Hz. N1 peak amplitudes were estimated from peak-to-peak measurements (from N1 to P1) and baseline-corrected measurements for 2 stimulus levels (80 and 110 dB pSPL). Baseline-corrected measurements were made with 4 baseline windows. Each stimulus level was presented twice, and test–retest reliability of these 2 measures was assessed using the intraclass correlation coefficient. Linear mixed models were used to evaluate the extent to which age group and click level uniquely predicted N1 amplitude and whether the predictive relationships differed between N1 measurement techniques. Results Both peak-to-peak and baseline-corrected measurements of N1 amplitude were found to have good-to-excellent reliability, with intraclass correlation coefficient values > 0.60. As expected, N1 amplitudes were significantly larger for younger participants compared with older participants for both measurement types and were significantly larger in response to clicks presented at 110 dB pSPL than at 80 dB pSPL for both measurement types. Furthermore, the choice of baseline window had no significant effect on N1 amplitudes using the baseline-corrected method. Conclusions Our results suggest that measurements of AN activity can be robustly and reliably recorded in both younger and older adults using either peak-to-peak or baseline-corrected measurements of the N1 of the CAP. Peak-to-peak measurements yield larger N1 response amplitudes and are the default measurement type for many clinical systems, whereas baseline-corrected measurements are computationally simpler. Furthermore, the relationships between AN activity and stimulus- and participant-related variables were not affected by measurement technique, which suggests that these relationships can be compared across studies using different techniques for measuring the CAP N1.