10 September 2015 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
SLStefano Lissandron
Stefano Lissandron
LSLuca Dalla Santa
Luca Dalla Santa
PMPaolo Mattavelli
Paolo Mattavelli
BWBo Wen
Bo Wen
The interactions of more and more power electronics-interfaced power systems can worsen the power quality and the system stability in distribution networks. System stability can be addressed by analyzing the source and load impedances at the interaction section, and well-established approaches exist for dc and three-phase ac networks. Some papers also focused on single-phase ac systems, whose study is generally more difficult due to their time-varying characteristics. Similar to the approaches based on dq rotating frame impedances, this paper focuses on single-phase systems using the dynamic phasor approach to determine the 2-D source and load impedances. The system stability is then evaluated using the generalized Nyquist stability criterion. As an example of application, a single-phase ac system that includes a current-controlled inverter synchronized to the grid through a phase-locked loop is proposed. Experimental validations are provided herein to verify the feasibility of this approach and the stability criteria based on the 2-D source and load impedances in the single-phase systems.

1 September 2014
Verified
Conference Paper
Closed access
SLStefano Lissandron
Stefano Lissandron
PMPaolo Mattavelli
Paolo Mattavelli
In this paper, a local controller for inverter of Distributed Energy Resources (DERs) is presented to manage a microgrid during grid-connected and autonomous operation modes and also during the transition. It is based on the P-f and Q-V droop control: during grid-connected operation, the controller tracks active and reactive power references and, during islanded mode, it exploits the droop control properties to share the load among the DERs. The peculiarity of this regulator is that it does not need to identify the particular operation mode and so a smooth transition from grid-connected to islanded mode can be achieved with no communication within the power grid or among the disconnecting switch and DERs. This controller has been implemented in a FPGA platform and its operation has been tested via an Hardware-In-the-Loop (HIL) and Real-Time (RT) simulation approach.

30 December 2015 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
RSRiccardo Sgarbossa
Riccardo Sgarbossa
SLStefano Lissandron
Stefano Lissandron
Paolo MattavelliPaolo Mattavelli
Paolo Mattavelli
Roberto TurriRoberto Turri
Roberto Turri
ACAlberto Cerretti
Alberto Cerretti
The large penetration of distributed energy resources (DERs), especially photovoltaic (PV), in low-voltage (LV) distribution grids has raised the concern of unintentional islanding operations. The probability of unintentional islanding is increased mainly due to the newly introduced standards with extended frequency and voltage thresholds and the additional grid support functions, such as active and reactive power regulation using P/f and Q/V droop characteristics. Moreover, islanding operation due to faulty events at the medium-voltage (MV) distribution level may be dangerous in the presence of automatic reclosing procedure leading to out-of-phase reconnections. In this paper, an analysis of this phenomena is provided using simplified generator and load models. Simulation results based on MATLAB and DIgSILENT tools on a simplified LV distribution network are reported together with experimental results on a lab-scale prototype.

1 June 2014
Verified
Conference Paper
Closed access
RSRiccardo Sgarbossa
Riccardo Sgarbossa
SLStefano Lissandron
Stefano Lissandron
PMPaolo Mattavelli
Paolo Mattavelli
Roberto TurriRoberto Turri
Roberto Turri
ACAlberto Cerretti
Alberto Cerretti
The interest of unintentional islanding operation has recently grown in Low Voltage (LV) distribution grids because of the large penetration of Distributed Energy Resources (DERs), especially the ones based on the PhotoVoltaic (PV) energy source. The probability of unintentional islanding is increased also due to the newly introduced standards with extended frequency and voltage limits before the PV protection trips and due to the large number of PV generators, which can make ineffective the anti-islanding provisions each PV is equipped with. Moreover, interconnection standards of DERs require some additional grid support functions, such as active and reactive power regulation using P/f and Q/V droop characteristics, which can further increase the probability of unintentional islanding. In this paper, an analysis of this phenomena is provided using a simplified static and dynamic characterization of the generators and the loads. Simulation results based on Matlab and DIgSILENT tools on a simplified LV distribution network are reported together with preliminary experimental results on a lab-scale prototype.

1 September 2013
Verified
Conference Paper
Closed access
SLStefano Lissandron
Stefano Lissandron
ACAlessandro Costabeber
Alessandro Costabeber
PMPaolo Mattavelli
Paolo Mattavelli
In recent years, the concept of multi-inverter microgrid as the building block for the future distribution system has been commonly accepted and widely studied in literature. One of the recognized advantages of microgrids is the possibility of operate autonomously in absence of the main utility supply. In this case, droop control techniques are the most attractive solution for their capability of operate the microgrid without requiring any communication among the inverters. This paper proposes a simple mathematical model of droop controlled islanded microgrids, with the objective of providing a tool by means of which a microgrid of arbitrary complexity can be modeled, and the local droop controllers of the inverters can be designed to guarantee the small-signal stability and achieve a satisfactory dynamic behaviour. The proposed model has been validated through Matlab/Simulink simulation.

1 June 2015
Verified
Conference Paper
Closed access
SLStefano Lissandron
Stefano Lissandron
RSRiccardo Sgarbossa
Riccardo Sgarbossa
LSLuca Dalla Santa
Luca Dalla Santa
PMPaolo Mattavelli
Paolo Mattavelli
Roberto TurriRoberto Turri
Roberto Turri
ACAlberto Cerretti
Alberto Cerretti
The analysis of unintentional islanding in distribution grids with a large penetration of renewable energy sources is of increasing interest due to the recently introduced requirements of P/f and Q/V supporting capabilities of Distributed Energy Resources (DERs) and the wider frequency and voltage ranges, DERs should be able to operate with, before protection tripping. DER anti-islanding protections, if present, may fail to detect this grid transition and so uncontrolled islanding operation may appear. Since this operating mode may be dangerous for the electric network operation and may cause damages for the grid equipment, in this paper the increase of its risk due to P/f and Q/V droop characteristics of generators is addressed. Analytic results are initially derived for the steady-state unintentional islanding operation and then they are validated on a laboratory-scale grid setup. The proposed investigation will show that the risk of permanent unintentional islanding increases introducing P/f or Q/V droop regulation and that such risk is maximum including both the P/f and Q/V droop regulations, rather than only one of them.