Veera Nagi Reddy Varampati

Dr. Veera Nagi Reddy Varampati

Department of Engineering & Technology, University of Technology and Applied Sciences, Ibri, Oman, Ibri, Oman
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Ain Shams Engineering Journal
Verified
Journal Article
Open access
Veera Nagi Reddy VarampatiVeera Nagi Reddy Varampati
Veera Nagi Reddy Varampati
VKVenkata Reddy Kota
Venkata Reddy Kota
DKD.V. Ashok Kumar
D.V. Ashok Kumar

1 December 2019 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
Veera Nagi Reddy VarampatiVeera Nagi Reddy Varampati
Veera Nagi Reddy Varampati
DKD.V Ashok Kumar
D.V Ashok Kumar
VKVenkata Reddy Kota
Venkata Reddy Kota
Unified Power Quality Conditioner (UPQC) is substantial power conditioner in power system to filter the power system parameters with an objective to improve the quality of power delivered to the customers/utility point. This paper presents a multi-level UPQC to enhance the quality in power distribution system. The series and shunt controllers of UPQC gives out five leveled output which is further filtered to feed compensating signals to improve voltage and current profiles in power distribution system. Series and shunt controllers of UPQC are structured with cascaded H-Bridge (CHB) topology to deliver compensating signals. Two separate control strategies are employed to regulate the power switches of 5-level CHB series and shunt controllers of UPQC. Sag and swell in source voltage and harmonics in source current are strained with UPQC. The proposed system is developed and results are obtained using MATLAB/SIMULINK software.

26 June 2020 in International Journal of Ambient Energy
Verified
Journal Article
Closed access
Veera Nagi Reddy VarampatiVeera Nagi Reddy Varampati
Veera Nagi Reddy Varampati
DKD. V. Ashok Kumar
D. V. Ashok Kumar
VKVenkata Reddy Kota
Venkata Reddy Kota
Uninterrupted power supply delivered to the customers maintaining power factor, frequency and voltage within permissible limits with good shape close to ideal format is the highest priority for power engineers. Some among power quality issues like sag swell and harmonics depreciate the standard of the power distribution network and power quality enhancement in power distribution system increases the performance efficiency and life of the equipment. The little enhancement in voltage and current quality makes significant increase in the performance and life of the equipment. One among FACTS controllers like UPQC delivers solution to nullify the power quality issues and the paper presents multi-level UPQC for power quality augmentation. The proposed control scheme uses multi layer perceptron neural network and weights are updated by fuzzy logic to generate reference signal. Control of UPQC makes power quality issues to be resolved effectively under fault conditions and this paper presents the comparative analysis of PI, fuzzy controlled UPQC with hybrid fuzzy-multi-layer perceptron network (MLPN) based control scheme for power quality improvement using MATLAB/SIMULINK software. The obtained results proved that fuzzy-MLPN UPQC compensated voltage sag, swell, harmonics, unsymmetrical LG and LLG faults voltage and current imbalance in the power distribution system.

4 November 2020 in Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)
Verified
Journal Article
Closed access
PDF file
Veera Nagi Reddy VarampatiVeera Nagi Reddy Varampati
Veera Nagi Reddy Varampati
DKD.V. Ashok Kumar
D.V. Ashok Kumar
VKVenkata Reddy Kota
Venkata Reddy Kota
Background: This paper presents voltage and current quality improvement in high/medium electrical distribution system using modulated multilevel unified power quality conditioner (MM-UPQC). Nowadays, power quality is one of the major issues due to the increase in usage of more non-linear loads in agricultural, commercial, industrial sectors. The industrial loads produce large amount of harmonics and power imbalances, which cause various power quality related issues like poor power factor, voltage sag, voltage swell, voltage interruption etc. Methods: The prime objective of this work is to design fuzzy-PI based controller based modulated multilevel UPQC for mitigation of issues related to power quality under unsymmetrical fault conditions such as LG fault and LLG fault. Results: This paper uses Instantaneous Reactive Power Theory (IRP) for phase angle adjustment with PI-fuzzy controller scheme to generate accurate reference signal for shunt and series controller of MM-UPQC. The detailed comparative analysis results of simultaneous voltage sag, swell, harmonics compensation and unsymmetrical faults mitigation are presented alongwith the MATLAB/SIMULINK software. Conclusion: Total harmonic distortion analysis is tabulated with PI and fuzzy-PI controller based MM-UPQC for different operating conditions in 4.16 KV distribution system.

1 January 2025 in Brazilian Archives of Biology and Technology
Verified
Journal Article
Open access
Veera Nagi Reddy VarampatiVeera Nagi Reddy Varampati
Veera Nagi Reddy Varampati
VKVenkata Reddy Kota
Venkata Reddy Kota
AVAshok Kumar Devarasetty Venkata
Ashok Kumar Devarasetty Venkata
To improve the performance of end-user equipment in an electric utility distribution network, it is necessary to improve power quality (PQ). This paper presents PQ improvement in electric distribution network using seven-level five switch converter based Unified Power Quality Conditioner (7LFSC-UPQC). Nowadays, power quality plays a vital role in the power distribution sector in the use of highly non-linear loads. Industrial non-linear loads produce electrical imbalances, thereby causing various voltage and current quality related problems, large amounts of harmonics, voltage swell, voltage sag, voltage interruption, etc. This paper proposes the design of a 7LFSC -UPQC based fuzzy-multilayer feed forward multi-layer neural network (FFMLNN) controller to mitigate PQ issues such as voltage sags, swells and current harmonics. A multi-layer feed forward neural network, in which a back-propagation algorithm is used to generate the appropriate reference voltage and current signals, and a shunt compensator of a seven-level unified power quality conditioner (UPQC). This proposed control scheme also controls the DC-link voltage and terminal voltage using an intelligent fuzzy controller. The performance of the proposed FFMLN-fuzzy based 7LFSC-UPQC configuration for simultaneous voltage swell, sag and total harmonic distortion is demonstrated and a comparative analysis of 7LFSC-UPQC and five level UPQC with PI-controller, fuzzy-controller and FFMLNN-controller is conducted using MATLAB/SIMULINK software.