Web openings in reinforced concrete deep beams are often necessary for functional purposes but substantially reduce structural performance. Carbon fiber-reinforced polymer (CFRP) strengthening is commonly employed to mitigate these effects. Previous studies typically examined openings in regions without stirrups or assumed closed stirrup configurations, overlooking the frequent stirrup damage that occurs in practice due to the high shear reinforcement in deep beams. In this study, three specimens from a prior experimental program were modeled in ABAQUS, and the numerical results were validated against experimental data. Openings of varying diameters were introduced by cutting reinforcements, and the beams were subsequently strengthened with CFRP laminates, and a parametric study was conducted. Results showed that increasing opening diameter markedly reduces load-carrying capacity and energy absoption, while thicker CFRP laminates partially restore performance. For example, a 300 mm opening in a 500 mm high unstrengthened beam reduced load capacity by 56% and energy absorption by 87%. Even when the opening diameter was less than one-third of the beam height, 1.8 mm CFRP laminates provided only limited improvement. Deep beam performance was strongly influenced by web opening size, and the effectiveness of CFRP strengthening was limited when stirrup integrity was compromised.
Web openings are created in reinforced concrete deep beams for various purposes. The CFRP strengthening technology is commonly employed to mitigate the adverse consequences of these openings. The impact of openings generated in areas of stirrupless or by arranging the stirrups at the bottom and top chords of the opening in a closed configuration has been examined in numerous studies. However, in reality, stirrup damage frequently occurs when openings are made due to the high number of stirrups employed in deep beams. In this study, three specimens tested in a previous experimental study were modeled via ABAQUS, and the results obtained were validated by comparing them with the experimental results. To create openings of varying sizes in the elements, the reinforcements were cut, and these beams were strengthened with CFRP laminates, followed by a parametric study. The findings indicated a 56% reduction in the load-carrying capacity of the unstrengthened beam (h = 500 mm) featuring a 300 mm diameter opening, alongside an 87% decrease in energy dissipation. Although the diameter of the opening, which was formed by cutting the stirrups, is less than one-third of the beam's height, the application of 1.8 mm thick laminates resulted in only limited improvement.
Direct comparison of compressive strength (fc) results obtained from different specimen geometries remains a major challenge in geopolymer concrete research because it limits data consistency and the reliability of engineering assessments. Owing to the lack of strength conversion models specifically developed for geopolymer concretes, fixed conversion factors established for Ordinary Portland Cement concretes are commonly adopted. However, the mechanical behavior of geopolymer concrete is strongly influenced by matrix chemistry, activator characteristics, and curing conditions, making the use of a single fixed conversion factor questionable. In this study, the geometry-dependent fc conversion behavior of fly ash (FA)-based geopolymer concrete was investigated using a database comprising 1,247 observations from four specimen geometries. The governing parameters were identified through Pearson and Spearman correlation analyses, Mutual Information, Random Forest, and SHAP-based explainable artificial intelligence. The SiO₂/Al₂O₃ ratio and alkaline liquid-to-binder ratio were identified as the dominant parameters. Based on these findings, a geometry-dependent semi-empirical conversion model incorporating specimen volume, geopolymer matrix chemistry, and reaction efficiency was developed. The proposed model achieved higher predictive accuracy than conventional fixed conversion-factor approaches across all specimen geometries. Validation using splitting tensile strength predictions confirmed improved estimation of derived mechanical properties. Structural validation of reinforced concrete columns further demonstrated that the selected conversion approach directly affects predicted load-carrying capacity, with differences reaching approximately 18% for 150×150×150 mm cube specimens at higher strength levels. The proposed model provides a practical framework for harmonizing fc data and improving the reliability of structural analysis and design of FA-based geopolymer concrete members.
About Me
Mechanics of reinforced concrete members, especially fiber reinforced concrete members.
Mechanics of reinforced concrete members, especially fiber reinforced concrete members.