Jacek Salach

Dr. Jacek Salach

Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Boboli 8, 02-525 Warszawa, Poland
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014
Verified
Book Chapter
Closed access
PDF file
OPOleg Petruk
Oleg Petruk
Roman SzewczykRoman Szewczyk
Roman Szewczyk
TCTymoteusz Ciuk
Tymoteusz Ciuk
WSWłodzimierz Strupiński
Włodzimierz Strupiński
JSJacek Salach
Jacek Salach
KTKrzysztof Trzcinka
Krzysztof Trzcinka

1 November 2010 in Acta Physica Polonica A
Verified
Journal Article
Closed access
ABA. Bieńkowski
A. Bieńkowski
Roman SzewczykRoman Szewczyk
Roman Szewczyk
JSJacek Salach
Jacek Salach

22 March 2012 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
JSJacek Salach
Jacek Salach
LHLech Hasse
Lech Hasse
Roman SzewczykRoman Szewczyk
Roman Szewczyk
Janusz SmulkoJanusz Smulko
Janusz Smulko
ABAdam Bienkowski
Adam Bienkowski
AKAleksandra Kolano-Burian
Aleksandra Kolano-Burian
Metal oxide surge arresters have been widely used for protection of power system networks against overvoltages caused by atmospheric discharges or malfunction of devices connected to the network. During its operation, a surge arrester structure is degradated, which can be observed as an increase of a surge arrester leakage current. This paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current transformer for monitoring of a leakage current in low voltage surge arresters. The characteristics of the current transformer for different loads have been measured in the system using very sensitive current-voltage converter. Experimental results confirmed that low current transformer utilizing Co64Fe4Ni1Si15B14 amorphous alloy in annealed state gives a possibility to measure a leakage current about several μA with operating frequency 50 Hz. Moreover, the results indicate that the leakage current waveforms have a different shape than a pure sine wave voltage applied to the surge arrester enabling an evaluation of the device nonlinearity as a measure of its degradation by means of a resistive component of the leakage current.

22 March 2012 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
PFPiotr Frydrych
Piotr Frydrych
Roman SzewczykRoman Szewczyk
Roman Szewczyk
JSJacek Salach
Jacek Salach
KTKrzysztof Trzcinka
Krzysztof Trzcinka
Miniature fluxgate sensors are recently intensively developed and have become a valuable alternative to other magnetic sensors types. Presented two-axis miniature fluxgate sensors show new opportunities for further miniaturization of fluxgate magnetometers. Frame-shaped amorphous alloys cores for the sensors were etched from 25 μm-thick tape. Sensors were made in printed circuit board (PCB) multilayer technology. Sensors with Fe-based and Co-based cores were tested for different values of constant magnetic field in two directions. Experimental results confirmed their ability to accurately obtain two directional magnetic field measurements.

1 October 2008 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
Roman SzewczykRoman Szewczyk
Roman Szewczyk
ABAdam Bieńkowski
Adam Bieńkowski
JSJacek Salach
Jacek Salach