In speed control systems of induction motor electrical drives, real-time speed monitoring is necessary. Speed monitoring can be done using the direct method, which uses a mechanical sensor mounted on the motor shaft, or the indirect method, which is based on estimation, mainly from the dynamic model of the motor. Speed estimation based on the dynamic model of the motor in orthogonal coordinates is the most widespread method in sensorless speed control systems of three-phase squirrel cage induction motor electrical drives, especially those of high accuracy. This paper presents the open-loop speed estimator used for speed estimation in three-phase induction motors. The proposed speed estimators are based on the orthogonal coordinate’s dynamic model of an induction motor in a stator reference frame. This technical solution is simple and has a low cost. The currents and voltages of the two motor phases are the input variables of the estimator, while the output variable is the induction motor speed. The speed estimator model is built using LabVIEW software. The dynamics and accuracy of the estimator proposed in this paper have been tested experimentally. The speed measured by the industrial incremental encoder is compared with that of a speed estimator modeled in LabVIEW software. The obtained experimental results show a good match between the measured and estimated speeds under the step torque load changes of the induction motor.
The increasing penetration of photovoltaic (PV) systems has raised concerns about power quality due to the harmonic distortion injected during DC–AC conversion by inverters. These harmonics can interfere with nearby electrical devices and compromise grid stability. This paper presents a LabVIEW-based virtual instrument designed specifically for real-time monitoring, analysis, and mitigation of voltage and current harmonics in grid-connected PV systems. The core contribution of this work lies in the development of an interactive, software-based platform that not only measures total harmonic distortion (THD) in real time but also allows users to design and simulate harmonic filters dynamically. The system achieved a reduction of current THD by 52% and voltage THD by 73% under tested conditions, demonstrating its effectiveness in improving power quality. Unlike conventional hardware-dependent solutions, the proposed tool offers a low-cost, easily customizable, and scalable approach suitable for educational laboratories, field diagnostics, and smart grid applications. By enabling remote control and filter tuning through LabVIEW, this solution supports the growing demand for intelligent power quality management and facilitates the seamless integration of renewable energy into modern electrical grids.
This paper investigates the operational performance and stability of a regional power grid with a high penetration of small hydropower plants operating under rated conditions. Grid monitoring and simulation results reveal that voltage levels frequently exceed permissible limits and exhibit significant fluctuations. The primary radial configuration of the network is the cause of often the outages of transmission lines that occur at times of peak generation. These conditions adversely affect generator operation and may contribute to equipment degradation. To enhance grid reliability and ensure stable hydropower plant operation, several mitigation measures are proposed, including the reinforcement of the transmission network through the construction of new lines to enable a ring configuration, the mandatory implementation of excitation control systems for generating units, the establishment of a real-time grid operation center, and the deployment of real-time diagnostic tools for optimized generator utilization. The proposed measures give a very handy scheme to raise voltage stability, operational reliability, and the safe inclusion of distributed hydropower generation into regional power systems.