Over the last two decades, robot-assisted minimally invasive surgery has become more accessible and has contributed to improved patient outcomes. However, its adoption in resource-constrained environments is limited due to the cost of the consumables, such as surgical instruments and access to sterilization facilities. These surgical instruments often have a tooltip with intricate geometry, making it difficult to sterilize and reuse for multiple surgeries. This research work introduces a novel minimally invasive surgical (MIS) instrument, the CLEANSurgiTip, which features a disposable grasper designed to address biofouling while reducing overall costs through minimized waste. Unlike traditional tendon-driven systems, which suffer from reliability issues and require frequent replacements, the CLEANSurgiTip utilizes rigid shafts to transmit motion to a distal 2 + 1 degrees-of-freedom (DoF) grasper (pitch, yaw, and grasp). These rigid shafts ensure a consistent cross section, simplifying the sealing process against bodily fluids. The transmission mechanism is simplified using an elbow mechanism and flexible shafts in place of conventional gears for orthogonal motion transmission. The flexible shaft aids in decoupling the pitch and the yaw motion. The tooltip design promotes a simplified interface between the disposable grasper and the reusable shaft, facilitating easy detachment. The paper also presents a novel reusable tool shaft to drive the proposed tooltip.
Walking canes can reduce knee loading in knee osteoarthritis by supporting a portion of body weight. Canes with load-dependent stiffness could modulate this load across stance, but no benchtop method characterizes such behavior. Cane standards (ISO 11334) test static strength, while prosthetic standards define body-mass-based load levels (ISO 10328) and gait-representative motion (ISO 22675). We combined the load levels of ISO 10328 and the motion of ISO 22675 into a benchmarking procedure for load-dependent canes. We recorded reaction force and marker-tracked deformation on a custom motor-driven platform. A commercial carbon-fiber C-shaped prosthetic blade with known nonlinear stiffness served as the reference specimen in two outsole orientations. When mapped to stance phase, the reverse orientation reduced force and the operational stiffness at heel strike and toe-off compared to forward orientation. While not designed as a cane, the blade demonstrates that nonlinear-stiffness elements can modulate the force response across stance. This mapping is approximate and requires human-subject validation. The operational stiffness under continuous motion differed in magnitude and profile from prior static stiffness measurements. A reduced-order formulation, assuming small rotation about the preloaded configuration, reproduced the measured operational stiffness to 6.6% RMSE with one identified coefficient. This parameter-identification method provides a framework for characterizing and designing nonlinear mechanisms in walking aids.