Background and Perspectives: Obstructive sleep apnea (OSA) is a prevalent condition associated with increased perioperative risks. Endobronchial ultrasound (EBUS), a diagnostic and staging procedure requiring deep sedation, may pose additional risks for patients at high risk of OSA. The Integrated Pulmonary Index (IPI), derived from capnography and vital signs, offers a single numerical value reflecting respiratory status. This study aimed to assess the association between high OSA risk and adverse events using the IPI during EBUS under sedation. Materials and Methods: This prospective cohort study included 65 patients undergoing EBUS with sedation between December 2024 and April 2025 at a tertiary referral center. STOP-Bang questionnaire scores were used to stratify patients into high- (≥3) and low-risk (<3) OSA groups. During the procedure, IPI, oxygen saturation, end-tidal carbon dioxide, respiratory rate, and hemodynamic parameters were recorded at multiple time points. Hypoxemia, hypoventilation, and apnea were defined using standard thresholds. Logistic regression and Generalized Linear Mixed Models (GLMM) were applied to examine associations between OSA risk and respiratory outcomes. Results: Forty-three patients (66.2%) were classified as high risk for OSA. Patients with high STOP-Bang scores were older and had higher BMI, comorbidity rates, and ASA scores (all p < 0.05). IPI values were lowest between 5 and 10 min, accompanied by more frequent interventions. Logistic regression showed no significant association between STOP-Bang scores and low IPI or hypoxemia. GLMM analysis also indicated no significant association between high OSA risk and low IPI (OR = 1.02; 95% CI = 0.36–2.86; p = 0.974). Hypoxemia was nearly threefold higher in high-risk patients, though not statistically significant (p = 0.080). Conclusions: Although no statistically significant association was identified between high OSA risk and adverse respiratory events, GLMM analyses revealed that patients with high STOP-Bang scores demonstrated approximately three times higher odds of developing hypoxemia (OR = 2.76; 95% CI = 0.99–7.66; p = 0.052), a result that approached statistical significance. The present findings do not support the routine use of IPI-based monitoring in this setting, and further adequately powered studies are warranted. The early procedural period (5–10 min) is critical for hypoxemia and respiratory compromise.
Introduction: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is widely used for diagnosing pulmonary diseases causing mediastinal lymphadenopathy. However, non-diagnostic results may occur. This study investigated factors associated with non-diagnostic cytological results in EBUS-TBNA. Methods: This retrospective study included patients who underwent EBUS-TBNA at a tertiary hospital between March 2019 and December 2023. Data on demographics, biopsy techniques, cyto-/histopathological results, sonographic lymph node measurements, and pre-procedural PET-CT SUVmax values were recorded. Cytological results were classified as diagnostic or non-diagnostic. We analyzed the characteristics and associated factors of patients who were non-diagnostically identified. Results: Among 776 patients undergoing EBUS-TBNA, 502 (64.7%) were male, with a mean age of 61.5 ± 12.6 years. A total of 1110 lymph nodes were sampled. Of the patients, 14.1% had a non-diagnostic cytology. Among the diagnosed patients, cytological findings showed 58.9% non-malignant, 41.1% malignant. The most sampled station was station 7 (72.9%), with an average of 5.9 ± 1.4 aspirations. Diagnostic cases had significantly more aspirations (p = 0.022) and sampled larger lymph node sizes (p < 0.001). Each 1 mm increase in lymph node size raised the likelihood of diagnostic results by 1.04 times (adjOR = 1.04, 95% CI = 1.02–1.08, p = 0.002). The largest lymph node size significantly predicted diagnostic results (AUROC = 0.611, p < 0.001). A cut-off of 19.55 mm had 67.0% sensitivity and 52.2% specificity. Conclusions: Sampled larger lymph nodes increase diagnostic yield in EBUS-TBNA, reducing the need for repeat procedures and enabling earlier treatment, thereby decreasing morbidity and mortality.