Eduardo Carasek

Prof. Eduardo Carasek

Universidade Federal de Santa Catarina, Florianópolis, Santa Catarina, Brazil
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2010 in Journal of Chromatography A
Verified
Journal Article
Closed access
FAFábio Augusto
Fábio Augusto
ECEduardo Carasek
Eduardo Carasek
RSRaquel Gomes Costa Silva
Raquel Gomes Costa Silva
SRSandra Regina Rivellino
Sandra Regina Rivellino
Alex BatistaAlex Batista
Alex Batista
EMEdmar Martendal
Edmar Martendal

1 June 2015 in Analytica Chimica Acta
Verified
Journal Article
Closed access
ECEduardo Carasek
Eduardo Carasek
JMJosias Merib
Josias Merib

3 October 2006 in Journal of Agricultural and Food Chemistry
Verified
Journal Article
Closed access
ECEduardo Carasek
Eduardo Carasek
JPJanusz Pawliszyn
Janusz Pawliszyn

1 June 2008 in Analytica Chimica Acta
Verified
Journal Article
Closed access
SRSanja Risticevic
Sanja Risticevic
ECEduardo Carasek
Eduardo Carasek
JPJanusz Pawliszyn
Janusz Pawliszyn


19 April 2010 in Applied Spectroscopy Reviews
Verified
Journal Article
Closed access
BWBernhard Welz
Bernhard Welz
SMSilvane Morés
Silvane Morés
ECEduardo Carasek
Eduardo Carasek
MVMaria Goreti R. Vale
Maria Goreti R. Vale
MOMichael Okruss
Michael Okruss
HBHelmut Becker-Ross
Helmut Becker-Ross
The present article gives an overview over the historic development, the instrumentation, the special features, and the applications of high-resolution continuum source atomic and molecular absorption spectrometry. The most obvious advantage is the need for only one single lamp for all elements and wavelengths, compared to one lamp for each analyte, as is necessary in line source atomic absorption spectrometry. The visibility of the spectral environment of the analytical line at high resolution greatly helps in method development and to avoid spectral interferences. The advanced simultaneous background correction automatically eliminates lamp flicker noise and continuous background absorption. Fine-structured background absorption may be removed using a reference spectrum and a least-squares algorithm. Because any wavelength between 190 nm and 900 nm can be accessed, the same equipment can be used for molecular absorption spectrometry, making possible the determination of non-metals, such as phosphorus, sulfur, and the halogens. Although commercial equipment for this technique has only been available for a few years, the technique has been accepted extremely well, and the number of applications that have been published using this technique has already reached an impressive number.