The recent reports from the Intergovernmental Panel on Climate Change (IPCC) urge for the reconceptualization of our design of the urban built environments. However, current efforts to integrate urban environmental assessment into practice in Egypt are proving insufficient. This paper utilises the Ladybug tools simulation plugins to investigate the impact of changing the morphological characteristics of three-block typologies (scattered, linear and courtyard) and their associated parameters to understand their multidimensional relationship with environmental conditions, outdoor thermal comfort and energy use intensity. This study based in Cairo, Egypt, considers 3430 hypothetical geometrical configurations comprising of a variety of design parameters and indicators. The results show a strong correlation between the design parameters and the combined performance of thermal comfort and energy consumption (R2 = 0.84), with urban density having the strongest impact on both thermal comfort and energy use (R2 = 0.7 and 0.95, respectively). The design parameters exhibited a consistent impact on the different typologies, albeit with varying magnitude. Compact and medium-density urban forms are shown to elicit the best overall performance, especially for ordinal orientations (e.g., ~45°) across all typologies. Compact high-density scattered forms are favoured when considering thermal comfort, while courtyards outperform other typologies when considering energy efficiency and overall performance.
Urban climatology is a complex field owed to the intersecting parameters. In city planning, neighborhood fabric and vegetation plays a great role in modifying arid microclimates. This work presents an approach to enable urban designers to find the optimum land use parameters to achieve pedestrian thermal comfort. In this study, a model was developed based on ENVI-met simulations of two urban and suburban sites in Cairo, Egypt. Initial design parameters were; compactness degree, grass coverage, leaf area density, trees ground coverage, and asphalt and buildings areas. After regression analysis, the step-wise algorithm succeeded in creating the best fit of 94% R2 and 92% adjusted R2. The suggested Urban Design Comfort Model (UDCM) was examined using MATLAB to find the optimum design parameters. Optimum values were applied to generate primitive urban configurations using Grasshopper. The primitives were simulated again in ENVI-met to validate UDCM. The resulted value of Physiological Equivalent Temperature, PET at peak time was reduced from the initial result of ENVI-met (42.3 °C) in both sites to reach (38.7 °C) then (36.8 °C) after refinement with extra foliage. This approach, as a tool for urban designers, not only facilitates and speeds up urban form design process on a passive basis, but also provides deep insights on the development of UDCM considering all different city transects rather than two.
1 April 2018 in The International Conference on Civil and Architecture Engineering
Outdoor microclimate simulations nowadays are indispensable processes during the early stages of designing sustainable urban forms, which contribute in achieving acceptable thermal comfort degrees, by adopting passive design strategies on both urban and single building scales especially in Hot Arid Regions, which is a substantial climate change mitigation methodology to reduce the impact of urban heat island, and greenhouse gases emissions. Simulations using the numerical microclimate model ENVI-met, despite giving precise results, are time consuming and lacking the availability to be utilized in iterated, form-finding processes. On the other hand, parametric Ladybug Tools, are mainly used as interfaces for validated simulation software such as EnergyPlus, OpenStudio, or OpenFOAM to utilize them in a parametric manner, with a seamless connections among them to finally conduct indoor/outdoor microclimate maps, notwithstanding the absence of some detailed information. This paper compares results from both simulation tools by comparing the microclimate maps conducted from them, and also results at a specific receptor point. In this concern, Thermal comfort metrics like relative humidity, wind speed, air, mean radiant, and physiological equivalent temperatures readings are compared, in which the readings provided an acceptable range of errors, while the parametric workflow generates results for large simulation periods in less time than ENVI-met. The main concern of this validation process is to reach a passable accurate readings for available simulation tools which are aspired among most of sustainable urban form-finding researchers.