Muhammad Yousif

Dr. Muhammad Yousif

National University of Sciences and Technology (NUST)
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2023 in Renewable Energy
Verified
Journal Article
Closed access
MRMuhammad Ali Raza
Muhammad Ali Raza
Muhammad YousifMuhammad Yousif
Muhammad Yousif
MHMuhammad Hassan
Muhammad Hassan
MNMuhammad Numan
Muhammad Numan
SKSyed Ali Abbas Kazmi
Syed Ali Abbas Kazmi

1 November 2019 in Applied Energy
Verified
Journal Article
Closed access
XZXiaoqian Zhou
Xiaoqian Zhou
QAQian Ai
Qian Ai
Muhammad YousifMuhammad Yousif
Muhammad Yousif

30 November 2023 in Heliyon
Verified
Journal Article
Open access
MRMahnoor Rashid
Mahnoor Rashid
Muhammad YousifMuhammad Yousif
Muhammad Yousif
ZRZeeshan Rashid
Zeeshan Rashid
AMAoun Muhammad
Aoun Muhammad
MAMishal Altaf
Mishal Altaf
AMAdil Mustada
Adil Mustada
In the past decade, solar photovoltaic (PV) modules have emerged as promising energy sources worldwide. The only limitation associated with PV modules is the efficiency with which they can generate electricity. The dust is the prime ingredient whose accumulation on the surface of PV impacts negatively over its efficiency at a greater rate. This research aims to explore the effects of dust accumulation on the energy output and operating temperature of polycrystalline silicon PV panels situated in two different climatic regions of Pakistan, i.e., Islamabad and Bahawalpur. In both the regions, one PV module is kept in ambient environment for six weeks to allow dust to deposit over its surface and perform experimental analysis with one clean module as reference for performance comparison. After six weeks of atmospheric exposure, dusty modules displayed significantly smaller efficiency as a function of different dust densities in the two regions. Dust samples from both cities are collected and analyzed to evaluate their structural attributes and composition. The PV module in Islamabad region had a dust layer over its surface with a density of 6.388 g/m2 and its efficiency was reduced by 15.08%. In Bahawalpur region, the dust density was observed to be 10.254 g/m2 which caused the output power to be slashed by 25.42%. Temperature analysis of modules shows that dust increases their temperatures which is also a quantity responsible for lower PV power generation with same amount of irradiance. The research findings are crucial for determining and predicting PV power degradation in two different atmospheres and determining the schedule of cleaning cycle.

25 December 2023 in IET Renewable Power Generation
Verified
Journal Article
Open access
MAMishal Altaf
Mishal Altaf
Muhammad YousifMuhammad Yousif
Muhammad Yousif
HIHaris Ijaz
Haris Ijaz
MRMahnoor Rashid
Mahnoor Rashid
NANasir Abbas
Nasir Abbas
ASAhmed Mohammed Saleh
Ahmed Mohammed Saleh
The transition from conventional fossil‐fuel vehicles to electric vehicles (EVs) is critical for mitigating environmental pollution. The placement of electric vehicle charging stations (EVCS) significantly impacts the utility operator and electrical network. Inappropriately placed EVCS lead to challenges such as increased load, unbalanced generation, power losses, and reduced voltage stability. Incorporating distributed generation (DG) helps mitigate these issues by maximizing EV usage. This study focuses on optimizing EVCS and DG placement in radial distribution networks. The methodology employs a backward and forward sweep method for load flow analysis and utilizes the particle swarm optimization (PSO) algorithm to determine optimal EVCS and DG locations and sizes. This approach, validated on the IEEE‐33 bus system, outperforms existing methods. Results indicate a 2.5 times greater power loss reduction compared to simulated annealing (SA), 1.6 times better than artificial bee colony, and parity with genetic algorithm (GA). Overall, the PSO algorithm demonstrates superior optimization effectiveness and computational efficiency, showcasing 1–2.5 times better performance than other methodologies. Employing this approach yields significantly improved results, making it a promising technique for optimizing EVCS and DG placement in distribution networks.

24 March 2023 in IEEE Access
Verified
Journal Article
Open access
MNMuhammad Numan
Muhammad Numan
MAMuhammad Farasat Abbas
Muhammad Farasat Abbas
Muhammad YousifMuhammad Yousif
Muhammad Yousif
Sherif GhoneimSherif Ghoneim
Sherif Ghoneim
AMAlsharef Mohammad
Alsharef Mohammad
ANAbdulfattah Noorwali
Abdulfattah Noorwali
The integration of variable renewable energy sources (RES) into power grids has resulted in a more complex operating environment for power system operators (SO), necessitating the need for increased grid flexibility. This is crucial for utilities, as the cost-effective utilization of existing infrastructure is necessary, given the prolonged construction period and high investment costs associated with building new power delivery facilities. Under the umbrella of smart grid, optimal transmission switching (OTS) is a cost-effective transmission technology that can alleviate concerns related to network congestion, limited transmission capacity, and high penetration of renewables. OTS is a concept that is integrated into the optimal power flow (OPF) problem such that it provides SO the choice to temporarily switch one or more lines out of service from the network. OTS is shown in the literature to have economic benefits, reduce operational cost, relieve network congestion, serve as a corrective mechanism for reducing voltage violations, improve system reliability, and minimize system loss. Despite the significant attention given to OTS by researchers over the past decade, no extensive review paper exists on the topic in the literature. Therefore, this paper provides a state-of-the-art overview of the OTS problem. The concept of OTS is explained by approximating the alternating current OPF problem into a linear direct current OPF problem. Various alternative models of the OTS problem proposed in the literature are discussed. The paper also analyzes the interaction between OTS and other flexibility options such as Dynamic thermal rating (DTR), Energy storage systems (ESS), and RES. Furthermore, the paper presents the general framework and impact of the short-term OTS problem on long-term expansion planning problems. Finally, an extensive literature review on the impact of OTS on system reliability is provided.

10 August 2023 in Energies
Verified
Journal Article
Open access
PDF file
ISIzhar Us Salam
Izhar Us Salam
Muhammad YousifMuhammad Yousif
Muhammad Yousif
MNMuhammad Numan
Muhammad Numan
Kamran ZebKamran Zeb
Kamran Zeb
MBMoatasim Billah
Moatasim Billah
The integration of distributed generation (DG) into distribution networks introduces uncertainties that can substantially affect network reliability. It is crucial to implement appropriate measures to maintain reliability parameters within acceptable limits and ensure a stable power supply for consumers. This paper aims to optimize the location, size, and number of DG units to minimize active power losses and improve distribution System (DS) reliability while considering system operational constraints. To achieve this objective, multiple tests are conducted, and the particle swarm optimization (PSO) technique is implemented. The simulation studies are performed using the ETAP software 19.0.1 version, while the PSO algorithm is implemented in MATLAB R2018a. ETAP enables a comprehensive evaluation of the DG system’s performance, providing valuable insights into its effectiveness in reducing power losses and enhancing system reliability. The PSO algorithm in MATLAB ensures accurate optimization, facilitating the identification of the optimal DG unit location and size. This study uses a modified IEEE-13 bus unbalanced radial DS as the test system, assessing the effects of photovoltaic (PV) and wind DG units under various scenarios and penetration levels. The results demonstrate that the optimal DG unit location and size of either a single PV or wind DG unit significantly reduce power losses, improve DS reliability, and enable effective load sharing with the substation. Moreover, this study analyzes the impact of DG unit uncertainty on system performance. The findings underscore the potential of optimized DG integration to enhance DS efficiency and reliability in the presence of renewable energy sources.