Gonzalo Manuel Delgado Valdiviezo

Gonzalo Manuel Delgado Valdiviezo

Auto-generated profile, based on publicly available information

Gonzalo Manuel Delgado Valdiviezo


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MRMIGUEL ANGEL LOZADA RUFINO
MIGUEL ANGEL LOZADA RUFINO
EZEulogia Isabel Zapata
Eulogia Isabel Zapata
GDGonzalo Delgado
Gonzalo Delgado
RCRosa Gisela Ortiz Castillo
Rosa Gisela Ortiz Castillo
GGGrecia Xiomara Herrera Gavilan
Grecia Xiomara Herrera Gavilan
KGKarina Silvana Gutiérrez-Valverde
Karina Silvana Gutiérrez-Valverde
Cadmium contamination in fruits is a relevant food-safety concern because of its toxicity, environmental persistence, and potential transfer from agricultural soils to edible plant tissues. This study developed a screen-printed carbon electrode modified with graphene oxide and cysteamine (SPCE/GO–cysteamine) to determine Cd(II) by square-wave anodic stripping voltammetry (SWASV). Two surface-modification routes, GO-cysteamine and GO-rGO-cysteamine, and GO concentrations of 0.1, 0.2, and 0.5 mg m⁻¹ were compared by cyclic voltammetry. The direct GO-cysteamine route at 0.2 mg mL⁻¹ gave the best electrochemical response and was selected for Cd(II) determination. Raman spectroscopy and scanning electron microscopy were used to characterize the graphene-based materials employed during surface optimization. In standard solutions, the platform showed a linear response from 1 to 10 µg L⁻¹, with a sensitivity of 11.2865 µA (µg L⁻¹)⁻¹, R² = 0.9892, a limit of detection of 0.98 µg L⁻¹, and a limit of quantification of 2.97 µg L⁻¹. Fortified Kent mango and Hass avocado digestates also showed concentration-dependent responses, with R² values of 0.9799 and 0.9788, respectively, and relative standard deviations below 5%. These results demonstrate the feasibility of the SPCE/GO–cysteamine platform for Cd(II) determination in digested fruit matrices and support its further development as a portable screening approach for food-quality control.

29 September 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
MRMIGUEL ANGEL LOZADA RUFINO
MIGUEL ANGEL LOZADA RUFINO
EZEulogia Isabel Zapata
Eulogia Isabel Zapata
GVGonzalo Manuel Delgado Valdiviezo
Gonzalo Manuel Delgado Valdiviezo
RCRosa Gisela Ortiz Castillo
Rosa Gisela Ortiz Castillo
GGGrecia Xiomara Herrera Gavilan
Grecia Xiomara Herrera Gavilan
KGKarina Silvana Gutiérrez-Valverde
Karina Silvana Gutiérrez-Valverde
Cadmium contamination in fruits is a relevant food-safety concern because of its toxicity, environmental persistence, and potential transfer from agricultural soils to edible plant tissues. This study developed a screen-printed carbon electrode modified with graphene oxide and cysteamine (SPCE/GO–cysteamine) to determine Cd(II) by square-wave anodic stripping voltammetry (SWASV). Two surface-modification routes, GO-cysteamine and GO-rGO-cysteamine, and GO concentrations of 0.1, 0.2, and 0.5 mg mL−1 were compared by cyclic voltammetry. The direct GO-cysteamine route at 0.2 mg mL−1 produced the highest CV response among the tested conditions and was selected for Cd(II) determination. Raman spectroscopy FTIR spectroscopy and scanning electron microscopy were used to characterize the graphene-based materials employed during surface optimization. Cd(II) concentrations from 1 to 10 µg L−1 were experimentally evaluated; with a calculated LOQ of 0.74 µg L−1, the entire experimentally evaluated range of 1–10 µg L−1, with a sensitivity of 11.30 µA (µg L−1)−1, R2 = 0.9892, a limit of detection of 0.25 µg L−1 and a limit of quantification of 0.74 µg L−1. Fortified Kent mango and Hass avocado digestates also showed concentration-dependent responses, with R2 values of 0.9799 and 0.9788, respectively, and relative standard deviations below 5%. These results demonstrate the feasibility of the SPCE/GO–cysteamine platform for Cd(II) determination in digested fruit matrices and support its further development as a portable screening approach for food-quality control.