This study evaluates the long-term operational performance of a full-scale reverse osmosis desalination plant treating highly mineralized water under real industrial operating conditions. Unlike conventional laboratory or pilot-scale investigations, the analysis is based on four years of operational data (2020–2024), providing a representative assessment of membrane system behavior under variable environmental and hydraulic conditions. Statistical analyses including descriptive statistics, time-series analysis, Pearson correlation, and inter-annual comparisons were performed using Python-based data-processing tools. An Operational Stability Index was also introduced to quantify process consistency over time. The results demonstrate stable desalination performance, with salt rejection exceeding 90%. Operational monitoring indicated effective pretreatment conditions, low SDI values, and controlled membrane fouling under long-term operation. Differential pressure evolution and cleaning-in-place performance further confirmed the effectiveness of the implemented fouling mitigation strategy. Membrane autopsy investigations revealed the coexistence of biological fouling, silica scaling, and localized oxidative degradation, highlighting the importance of integrated pretreatment and operational control. The findings demonstrate the value of long-term industrial monitoring for understanding membrane performance, fouling behavior, and operational stability in full-scale RO systems. This approach supports data-driven operational optimization and may contribute to the future development of predictive monitoring and intelligent desalination-management frameworks as a Digital Twin.

30 September 2026 in Membranes
Verified
Journal Article
Open access
PDF file
ESES SELLAMI SMAIL
ES SELLAMI SMAIL
TATALEB ABDESLAM
TALEB ABDESLAM
Mohammed EL HachoumiMohammed EL Hachoumi
Mohammed EL Hachoumi
AEAbdelkader ES-SELLAMI
Abdelkader ES-SELLAMI
Reverse osmosis (RO) digital twins require predictive models whose accuracy remains credible as plant operating conditions change. We evaluated the readiness of predictive models for a full-scale, two-stage RO plant using operational spreadsheets and temporally structured validation. An audit of 70 legacy worksheets identified heterogeneous layouts. A normalized source provided 476 train-day records from 17 operating months between June 2022 and November 2023, while 55 records from April and May 2024 formed an independent later-period holdout. Four supervised regression algorithms (Ridge Regression, Random Forest, Extra Trees, and Gradient Boosting) were evaluated for second-stage permeate flow and conductivity. Under a random split, Random Forest achieved R2 values of 0.876 and 0.833, with root mean square errors of 8.48 m3/h and 63.26 µS/cm, respectively. Chronological validation reduced R2 to 0.042 and 0.118. On the later holdout, R2 fell to −1.173 and −0.918, with corresponding root mean square errors of 11.14 m3/h and 218.65 µS/cm. Rolling-origin tests revealed substantial variability among successive periods. Distributional diagnostics identified changes in feed pressure, first-stage permeate conductivity, second-stage flow, and second-stage conductivity; the available data could not establish their physical causes. These findings show that performance under random splitting is insufficient to establish readiness for future use. A membrane-process digital twin requires traceable data, chronological evaluation, operating-regime surveillance, controlled model updates, and human-supervised advisory operation.

9 October 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Mohammed EL HachoumiMohammed EL Hachoumi
Mohammed EL Hachoumi
TATALEB ABDESLAM
TALEB ABDESLAM
MBMohammed Karim Benhachmi
Mohammed Karim Benhachmi
ESES SELLAMI SMAIL
ES SELLAMI SMAIL
Leakage diagnosis in water distribution networks is constrained by sparse instrumentation, uncertain models, and leak concurrency. We present a physics-informed spatio-temporal graph neural network evaluated end-to-end on the open Battle of the Leakage Detection and Isolation Methods (BattLeDIM) and L-Town benchmark (782 junctions, 905 pipes, 33 pressure sensors). Message passing operates on a conductance-weighted hydraulic Laplacian, trained by self-supervised sensor masking to reconstruct nodal pressure fields and latent pipe flows, embedding Hazen-Williams energy and mass-balance residuals in the loss under learned uncertainty weighting. Pressure at withheld sensors is reconstructed to 0.29 meters. A seeded ablation shows physical constraints degrade reconstruction accuracy by 0.10 meters of head while reducing nodal continuity violations by over five orders of magnitude, rendering the inferred state hydraulically admissible. Residuals feed two complementary detectors. A level-based statistic saturates under concurrent leakage; pairing it with a two-window onset contrast raises detection from 13 to 22 of 23 ground-truth leaks (95.7 %, 95 % confidence interval 79.0–99.2 %), with median detection times of 29 hours for abrupt and 74 hours for incipient events, releasing 96 % of annual leaked volume after detection. Localization transfers poorly from simulation, with a median error of 857 meters and only three leaks meeting the joint 300 meters criterion due to signal superposition under concurrency.

1 November 2026 in Ecological Engineering & Environmental Technology
Verified
Journal Article
Open access
PDF file
Mohammed EL HachoumiMohammed EL Hachoumi
Mohammed EL Hachoumi
ATAbdeslam TALEB
Abdeslam TALEB
MHMohammed Karim Ben Hachmi
Mohammed Karim Ben Hachmi
MLMohamed Laaouan
Mohamed Laaouan
Non-revenue water is a major pressure on drinking-water resources in semi-arid regions, where every cubic metre lost has already been abstracted, treated and pumped. This study evaluates a two-year active leakage control programme carried out by the national utility in Aïn Aouda, a Moroccan town...

10 June 2025
Verified
Book Chapter
Closed access
PDF file
Mohammed EL HachoumiMohammed EL Hachoumi
Mohammed EL Hachoumi
ATAbdeslam Taleb
Abdeslam Taleb
MBMohammed Karim Benhachmi
Mohammed Karim Benhachmi
ABAli EL Bilali
Ali EL Bilali
MLMohamed Laaouan
Mohamed Laaouan
SHSamir Hobaizi
Samir Hobaizi

1 October 2026 in AQUA — Water Infrastructure, Ecosystems and Society
Verified
Journal Article
Closed access
Mohammed EL HachoumiMohammed EL Hachoumi
Mohammed EL Hachoumi
ALI el bilaliALI el bilali
ALI el bilali
MLMohamed Laaouan
Mohamed Laaouan
ATAbdeslam TALEB
Abdeslam TALEB
Night flow falls from 76.2 to 35.7 L/s over two contract cycles and rebounds at a measured 17.1 L/s per year between them. Performance-based contracts are increasingly promoted for water loss reduction in middle-income countries, yet empirical evaluations of contracts remunerated on the minimum night flow are largely absent from the peer-reviewed literature. This study evaluated a two-year performance-based leak detection and repair contract covering a 212 km network with 15,500 service connections in Ain Aouda, Morocco, using 39 validated measurement nights across 14 campaigns, a georeferenced register of 1,229 repaired leaks, matched-site pressure records, and fully observed cost records. The contractor reduced the minimum night flow from 76.2 to 45.7 L/s on schedule; leakage then rebounded to 55.6 L/s within six months, yielding a natural rate of rise of unreported leakage of 17.1 L/s per year, before a second campaign reduced night flow to 35.7 L/s (a 53% reduction). Night pressures at matched sites were stable or lower during the rebound, excluding a pressure artifact and making the estimate conservative. With a measured night-day factor of 19.0 hours, the economic intervention interval from observed costs is 3 to 8 months as a central estimate, against 19 practiced, and the incremental cost of active leakage control lies below the utility's full cost of water. Design recommendations are proposed for night-flow-indexed contracts.