Roberto Franchini

Dr. Roberto Franchini

Sede di Lecce, Institute of Clinical Physiology CNR, Pisa, Tuscany, Italy
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
FCFrancesco Conversano
Francesco Conversano
Roberto FranchiniRoberto Franchini
Roberto Franchini
AGAntonio Greco
Antonio Greco
GSGiulia Soloperto
Giulia Soloperto
FCFernanda Chiriacò
Fernanda Chiriacò
SCSergio Casciaro
Sergio Casciaro

1 November 2010 in Investigative Radiology
Verified
Journal Article
Closed access
SCSergio Casciaro
Sergio Casciaro
FCFrancesco Conversano
Francesco Conversano
Andrea RagusaAndrea Ragusa
Andrea Ragusa
MMMaria Msc Ada Malvindi
Maria Msc Ada Malvindi
Roberto FranchiniRoberto Franchini
Roberto Franchini
GGGiuseppe Gigli
Giuseppe Gigli
Objectives: To experimentally investigate the acoustical behavior of silica nanoparticles within conventional diagnostic ultrasound fields and to determine a suitable configuration, in terms of particle size and concentration, for their employment as targetable contrast agents. We also assessed the effectiveness of a novel method for automatic detection of targeted silica nanoparticles for future tissue typing applications. Materials and Methods: Silica nanospheres of variable size (160, 330, and 660 nm in diameter) and concentration (1010–1013 part/mL) were dispersed in different custom-designed agarose-based gel samples and imaged at 7.5 MHz with a conventional echograph linked to a research platform for radiofrequency signal acquisition. Off-line analysis included evaluation of backscattered ultrasound amplitude, image brightness, and nanoparticle automatic detection through radiofrequency signal processing. Results: Amplitude of nanoparticle-backscattered signals linearly increased with particle number concentration, but image brightness did not show the same trend, because the logarithmic compression caused the reaching of a “plateau” where brightness remained almost constant for further increments in particle concentration. On the other hand, both backscatter amplitude and image brightness showed significant increments when particle diameter was increased. Taking into account particle size constraints for tumor targeting (pore size of tumor endothelium and trapping effects because of reticulo-endothelial system limit the dimension of effectively employable particles to less than 380 nm), a suitable compromise is represented by the employment of 330-nm silica nanospheres at a concentration of about 1 to 2 × 1011 part/mL. These particles, in fact, showed the best combination of number concentration and diameter value to obtain an effective enhancement on conventional echographic images. Furthermore, also the sensitivity of the developed method for automatic nanoparticle detection had a maximum (72.8%) with 330-nm particles, whereas it was lower with both bigger and smaller particles (being equal to 64.1% and 17.5%, respectively). Conclusions: Silica nanoparticles at a diameter of about 330 nm are very promising contrast agents for ultrasound imaging and specific tumor targeting at conventional diagnostic frequencies, being in particular automatically detectable with high sensitivity already at low doses. Future studies will be carried out to assess the acoustic behavior of nanoparticles with different geometries/sizes and to improve sensitivity of the automatic detection algorithm.

1 April 2011 in Academic Radiology
Verified
Journal Article
Closed access
FCFrancesco Conversano
Francesco Conversano
Roberto FranchiniRoberto Franchini
Roberto Franchini
Christian DemitriChristian Demitri
Christian Demitri
LMLaurent Massoptier
Laurent Massoptier
FMFrancesco Montagna
Francesco Montagna
SCSergio Casciaro
Sergio Casciaro

24 January 2011 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SCSergio Casciaro
Sergio Casciaro
Roberto FranchiniRoberto Franchini
Roberto Franchini
LMLaurent Massoptier
Laurent Massoptier
ECErnesto Casciaro
Ernesto Casciaro
FCFrancesco Conversano
Francesco Conversano
ALAimè Lay-Ekuakille
Aimè Lay-Ekuakille
An adaptive initialization method was developed to produce fully automatic processing frameworks based on graph-cut and gradient flow active contour algorithms. This method was applied to abdominal Computed Tomography (CT) images for segmentation of liver tissue and hepatic tumors. Twenty-five anonymized datasets were randomly collected from several radiology centres without specific request on acquisition parameter settings nor patient clinical situation as inclusion criteria. Resulting automatic segmentations of liver tissue and tumors were compared to their reference standard delineations manually performed by a specialist. Segmentation accuracy has been assessed through the following evaluation framework: dice similarity coefficient (DSC), false negative ratio (FNR), false positive ratio (FPR) and processing time. Regarding liver surfaces, graph-cuts achieved a DSC of 95.49% ( FPR=2.35% and FNR=5.10%), while active contours reached a DSC of 96.17% (FPR=3.35% and FNR=3.87%). The analyzed datasets presented 52 tumors: graph-cut algorithm detected 48 tumors with a DSC of 88.65%, while active contour algorithm detected only 44 tumors with a DSC of 87.10%. In addition, in terms of time performances, less time was requested for graph-cut algorithm with respect to active contour one. The implemented initialization method allows fully automatic segmentation leading to superior overall performances of graph-cut algorithm in terms of accuracy and processing time. The initialization method here presented resulted suitable and reliable for two different segmentation techniques and could be further extended.

10 March 2011 in IEEE Sensors Journal
Verified
Journal Article
Closed access
FCFrancesco Conversano
Francesco Conversano
Roberto FranchiniRoberto Franchini
Roberto Franchini
ALAimè Lay-Ekuakille
Aimè Lay-Ekuakille
SCSergio Casciaro
Sergio Casciaro
Recent literature has reported increasing interest in using contrast agents for ultrasound imaging, in the form of shelled gas microbubbles, for innovative advanced purposes such as noninvasive targeted imaging and drug delivery. Effectiveness of such agents is time-dependent and is determined by microbubble dissolution behavior, a complex phenomenon whose knowledge is still limited. In the present study, we monitored the microbubbles of an experimental phospholipid-shelled perfluorobutane contrast agent through time-scheduled size distribution measurements. The diameter-time curve we obtained for shelled perfluorobutane microbubbles showed a rapid diameter increment up to about 1.4 times the initial value, followed by a slow decrement towards bubble disappearance. This behavior is qualitatively similar to the one theoretically predicted by Kabalnov's model for unshelled bubbles, with an extended lifetime due to shell effect. Kabalnov's model, devised for spontaneous dissolution of unshelled microbubbles, was consequently modified in order to get a proper prediction of experimental results also in the case of encapsulated bubbles. A theoretical diameter-time curve was then derived from this new model and fitted to our experimental data points, to estimate microbubble surface tension and to determine the value of an empirical parameter accounting for the shell effect. The proposed model has the potential to predict the dissolution behavior of all kinds of microbubble contrast agents for ultrasound imaging and the adopted experimental methodology represents a new and simple way to estimate microbubble surface tension, essential also for predicting microbubble oscillation performance.

10 October 2011 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
FCFrancesco Conversano
Francesco Conversano
ECErnesto Casciaro
Ernesto Casciaro
Roberto FranchiniRoberto Franchini
Roberto Franchini
ALAime Lay-Ekuakille
Aime Lay-Ekuakille
SCSergio Casciaro
Sergio Casciaro
Current imaging methods for catheter position monitoring during minimally invasive surgery do not provide an effective support to surgeons, often resulting in the choice of more invasive procedures. This study was conducted to demonstrate the feasibility of non-ionizing monitoring of endovascular devices through embedded quantitative ultrasound (QUS) methods, providing catheter self-localization with respect to selected anatomical structures. QUS-based algorithms for real-time automatic tracking of device position were developed and validated on in vitro and ex vivo phantoms. A trans-esophageal ultrasound probe was adapted to simulate an endovascular device equipped with an intravascular ultrasound probe. B-mode images were acquired and processed in real time by means of a new algorithm for accurate measurement of device position. After off-line verification, automatic position calculation was found to be correct in 96% and 94% of computed frames in the in vitro and ex vivo phantoms, respectively. The average errors of distance measurements (bias ± 2SD) in a 41-step 10-cm-long parabolic pathway were 0.76 ± 3.75 mm or 0.52 ± 3.20 mm, depending on algorithm implementations. Our results showed the effectiveness of QUS-based tracking algorithms for real-time automatic calculation and display of endovascular system position. The method, validated for the case of an endoclamp balloon catheter, can be easily extended to most endovascular surgical systems.