Nazmul Ahosan

Nazmul Ahosan

Computer Science And Engineering, Canadian University of Bangladesh, Dhaka, Bangladesh

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
SASayor Aaron
Sayor Aaron
Sajjat Hossain AbirSajjat Hossain Abir
Sajjat Hossain Abir
Ashif NewazAshif Newaz
Ashif Newaz
MRMd. Mushfiqur Rahman
Md. Mushfiqur Rahman
Nazmul AhosanNazmul Ahosan
Nazmul Ahosan
MHMd. Monir Hossain
Md. Monir Hossain
Background/Objectives: Photoplethysmography (PPG) could support unobtrusive respiratory-rate monitoring during breathing-centered rehabilitation. Accuracy measured in one cohort, however, says little about how the same estimator will behave after deployment elsewhere. Confidence estimates may also fail. We tested whether physiology-informed artificial intelligence and a learned error-prediction gate retained their performance across two clinically distinct public datasets. Methods: We conducted a retrospective, subject-separated benchmark using 53 BIDMC intensive-care recordings and 42 CapnoBase anesthesia recordings. From 32 s PPG windows advanced every 8 s, we derived four respiratory modulations and 51 rate, agreement, morphology, and signal-quality features. Six estimators were evaluated by five-fold grouped cross-validation and by bidirectional external transfer. A nested gradient-boosting model predicted each estimate's absolute error to support selective reporting. Performance was summarized with subject-bootstrap confidence intervals, Bland–Altman agreement, and risk–coverage analysis. Results: The analysis included 5262 windows from 95 participants. Within-dataset mean absolute error (MAE) was lowest for random forest on BIDMC (1.65 breaths/min) and Extra Trees on CapnoBase (3.55 breaths/min). The physiology-consensus model achieved 1.70 and 4.02 breaths/min, respectively. Its learned gate reduced MAE at 50% coverage to 0.93 and 2.01 breaths/min. Under external transfer, however, its MAE increased to 6.19 breaths/min for BIDMC→CapnoBase and 4.90 breaths/min for CapnoBase→BIDMC. Uncertainty–error Spearman correlation fell from 0.48 and 0.41 internally to 0.15 and 0.09 externally, and gating yielded only modest improvement. A fixed raw-spectral baseline outperformed the learned model in both transfer directions. Conclusions: Confidence measured within the development cohort did not establish safety after transfer. PPG-derived respiratory rate needs external calibration before it can guide rehabilitation feedback, even when point accuracy appears acceptable internally. Public benchmarks should report bidirectional transfer and risk–coverage behavior alongside random or subject-wise internal splits.

15 October 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
SASayor Aaron
Sayor Aaron
Sajjat Hossain AbirSajjat Hossain Abir
Sajjat Hossain Abir
Ashif NewazAshif Newaz
Ashif Newaz
MRMd. Mushfiqur Rahman
Md. Mushfiqur Rahman
Nazmul AhosanNazmul Ahosan
Nazmul Ahosan
MHMd. Monir Hossain
Md. Monir Hossain
Background/Objectives: A model explanation can still look clinically credible after the model has stopped travelling well. Hospital transfer studies rarely test that mismatch directly. We examined whether predictions and feature attributions changed together when sepsis risk models moved between two hospital systems. Methods: We analyzed the public PhysioNet/Computing in Cardiology Challenge 2019 data. The cohort included adult stays with at least 24 hourly records and no positive sepsis label during the first 12 h. We derived 115 predictors from that 12-h window, then trained elastic-net logistic regression, random forest, and XGBoost models separately in systems A and B. Each fitted model was evaluated in its source system and, without target-site refitting, in the other system. We assessed calibration, a frozen source threshold chosen for 80% sensitivity, decision curves, subgroup performance, and 1000-resample bootstrap intervals. The XGBoost audit compared global SHAP rankings, top-10 overlap, attribution direction, missingness-attribution mass, an ablation without observation indicators, and classifiers trained to identify the hospital system. Results: The cohort comprised 30,646 stays with 1843 subsequent sepsis events. XGBoost AUROC fell from 0.725 internally to 0.608 after A→B transfer and from 0.702 to 0.636 after B→A transfer. External calibration slopes were 0.431 and 0.700. SHAP-rank correlations remained high at 0.949 and 0.917, yet the top-10 Jaccard overlap was only 0.667 in either direction; the within-site bootstrap reference was 1.000. Observation indicators contributed 24.7% of external attribution mass for A→B and 7.5% for B→A. On their own, those indicators identified the hospital system with AUROC 0.998, although removing them changed external AUROC by less than 0.01. Conclusions: The two hospitals left a clear signature in what clinicians measured and what they left unmeasured. That signature altered the explanation profile even when its incremental contribution to discrimination was small. External validation should test prediction, calibration, threshold behavior, and explanation stability together.