Percin Ozkorucuklu Sabriye

Prof. Dr. Percin Ozkorucuklu Sabriye

Department of Molecular Biology and Genetics, Istanbul University, Istanbul, İstanbul, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2008 in Sensors
Verified
Journal Article
Open access
PDF file
PSPercin Ozkorucuklu Sabriye
Percin Ozkorucuklu Sabriye
YSYucel Sahin
Yucel Sahin
GAGüleren Alsancak
Güleren Alsancak
In this work, preparation of a molecularly imprinted polymer (MIP) film and its recognition properties for sulfamethoxazolewere investigated. The overoxidized polypyrrole (OPPy) film was prepared by the cyclic voltammetric deposition of pyrrole (Py) in the presence of supporting electrolyte (tetrabutylammonium perchlorate-TBAP) with and without a template molecule (sulfamethoxazole) on a pencil graphite electrode (PGE). The voltammetric behaviour of sulfamethoxazole on imprinted and non-imprinted (NIP) films was investigated by differential pulse voltammetry (DPV) in Britton-Robinson (BR) buffer solutions prepared in different ratio of acetonitrile-water binary mixture, between the pH 1.5 and 7.0. The effect of the acetonitrile-water ratio and pH, monomer and template concentrations, electropolymerization cycles on the performance of the MIP electrode was investigated and optimized. The MIP electrode exhibited the best reproducibility and highest sensitivity. The results showed that changing acetonitrile-water ratio and pH of BR buffer solution changes the oxidation peak current values. The highest anodic signal of sulfamethoxazole was obtained in BR buffer solution prepared in 50% (v/v) acetonitrile-water at pH 2.5. The calibration curve for sulfamethoxazole at MIP electrode has linear region for a concentration range of 25.10-3 to 0.75 mM (R2=0.9993). The detection limit of sulfamethoxazole was found as 3.59.10-4 mM (S/N=3). The same method was also applied to determination of sulfamethoxazole in commercial pharmaceutical samples. Method precision (RSD87%) were satisfactory. The proposed method is simple and quick. The polypyrrole (PPy) electrodes have low response time, good mechanical stability and are disposable simple to construct.

1 March 2018 in Construction and Building Materials
Verified
Journal Article
Closed access
SES. Gamze Erzengin
S. Gamze Erzengin
KKKübra Kaya
Kübra Kaya
PSPercin Ozkorucuklu Sabriye
Percin Ozkorucuklu Sabriye
VÖVelican Özdemir
Velican Özdemir
GYGizem Yıldırım
Gizem Yıldırım

1 January 2010 in Dyes and Pigments
Verified
Journal Article
Closed access
FKFatma Karipcin
Fatma Karipcin
BDBülent Dede
Bülent Dede
PSPercin Ozkorucuklu Sabriye
Percin Ozkorucuklu Sabriye
EKEser Kabalcilar
Eser Kabalcilar

1 October 2013 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
BGBerrin Gürler
Berrin Gürler
PSPercin Ozkorucuklu Sabriye
Percin Ozkorucuklu Sabriye
EKEsengül Kır
Esengül Kır

9 February 2009 in Journal of Chemical & Engineering Data
Verified
Journal Article
Closed access
PSPercin Ozkorucuklu Sabriye
Percin Ozkorucuklu Sabriye
JBJose L. Beltrán
Jose L. Beltrán
GFGemma Fonrodona
Gemma Fonrodona
DBDolores Barrón
Dolores Barrón
GAGüleren Alsancak
Güleren Alsancak
JBJosé Barbosa
José Barbosa

15 December 2003 in Journal of Applied Polymer Science
Verified
Journal Article
Closed access
PDF file
YSYucel Sahin
Yucel Sahin
PSPercin Ozkorucuklu Sabriye
Percin Ozkorucuklu Sabriye
MŞMutlu Şahin
Mutlu Şahin
GÖGüleren Özkan
Güleren Özkan