Andrea Toffoli

Dr. Andrea Toffoli

Medicine and Surgery, University of Parma, Parma, Emilia-Romagna, Italy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Japanese Dental Science Review
Verified
Journal Article
Open access
LPLudovica Parisi
Ludovica Parisi
Andrea ToffoliAndrea Toffoli
Andrea Toffoli
BGBENEDETTA GHEZZI
BENEDETTA GHEZZI
BMBeatrice Mozzoni
Beatrice Mozzoni
SLSimone Lumetti
Simone Lumetti
GMGuido M. Macaluso
Guido M. Macaluso
The bioactivity of biomaterials is closely related to cell response in contact with them. However, shortly after their insertion, materials are soon covered with proteins that constitute the biological fluids, and which render the direct surface recognition by cells almost impossible. The control of protein adsorption at the interface is therefore desirable. Extracellular matrix proteins are of particular interest in this sense, due to their well-known ability to modulate cell behavior. Particularly, fibronectin plays a leading role, being present in both healthy and injured tissues undergoing healing and regeneration. The aim of the present work is to give an overview on fibronectin and on its involvement in the control of cell behavior providing evidence of its pivotal role in the control of cell adhesion, spreading, migration, proliferation and differentiation. A deep insight into methods to enrich biomaterials surface with fibronectin will be then discussed, as well as new cues on the possibility to design tailored platforms able to specifically retain fibronectin from the surrounding extracellular milieu.

1 December 2020 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
LPLudovica Parisi
Ludovica Parisi
BGBENEDETTA GHEZZI
BENEDETTA GHEZZI
MBMassimiliano G. Bianchi
Massimiliano G. Bianchi
Andrea ToffoliAndrea Toffoli
Andrea Toffoli
Francesca RossiFrancesca Rossi
Francesca Rossi
Guido Maria MacalusoGuido Maria Macaluso
Guido Maria Macaluso

1 February 2020 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
Andrea ToffoliAndrea Toffoli
Andrea Toffoli
LPLudovica Parisi
Ludovica Parisi
MBMassimiliano G. Bianchi
Massimiliano G. Bianchi
SLSimone Lumetti
Simone Lumetti
OBOvidio Bussolati
Ovidio Bussolati
Guido Maria MacalusoGuido Maria Macaluso
Guido Maria Macaluso

Verified
Journal Article
Open access
PDF file
LPLudovica Parisi
Ludovica Parisi
Andrea ToffoliAndrea Toffoli
Andrea Toffoli
GGGiulia Ghiacci
Giulia Ghiacci
Guido Maria MacalusoGuido Maria Macaluso
Guido Maria Macaluso
Tissue engineering (TE) is a multidisciplinary science, which including principles from material science, biology and medicine aims to develop biological substitutes to restore damaged tissues and organs. A major challenge in TE is the choice of suitable biomaterial to fabricate a scaffold that mimics native extracellular matrix guiding resident stem cells to regenerate the functional tissue. Ideally, the biomaterial should be tailored in order that the final scaffold would be (i) biodegradable to be gradually replaced by regenerating new tissue, (ii) mechanically similar to the tissue to regenerate, (iii) porous to allow cell growth as nutrient, oxygen and waste transport and (iv) bioactive to promote cell adhesion and differentiation. With this perspective, this review discusses the options and challenges facing biomaterial selection when a scaffold has to be designed. We highlight the possibilities in the final mold the materials should assume and the most effective techniques for its fabrication depending on the target tissue, including the alternatives to ameliorate its bioactivity. Furthermore, particular attention has been given to the influence that all these aspects have on resident cells considering the frontiers of materiobiology. In addition, a focus on chitosan as a versatile biomaterial for TE scaffold fabrication has been done, highlighting its latest advances in the literature on bone, skin, cartilage and cornea TE.

1 January 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
MNMassimiliano Negri
Massimiliano Negri
Carlo GalliCarlo Galli
Carlo Galli
ASArianna Smerieri
Arianna Smerieri
Guido Maria MacalusoGuido Maria Macaluso
Guido Maria Macaluso
EMEdoardo Manfredi
Edoardo Manfredi
SLSimone Lumetti
Simone Lumetti
Objectives.The goal of this study was to evaluate bone changes around endosseous implants in partially edentulous patients.Materials and Methods.A total of 632 two-stage implants were placed in 252 patients. The implants had straight emergence profile, ZirTi surface, 3.3 to 5 mm diameter, and 8.5 to 13 mm length. Bone levels were assessed on orthopantomography immediately after surgery and after 36 months and marginal bone loss (MBL) was calculated from their difference.Results.Cumulative survival rate was 98.73%. Overall MBL was 0.8 mm ± 0.03 (mean ± SEM). Higher MBL was observed around implants in the maxilla than in the mandible (P<0.007). A relation between implant diameter and MBL (P<0.0001) was observed in male and, more limitedly, female patients. Older patients had higher MBL in the maxilla, but not in the mandible (P<0.0001). MBL progressively increased with age in male patients, but reached a peak already in the 50–60 years age group in the female subset (P<0.001).Conclusions.The overall MBL is consistent with the available literature. Site difference and patient age and gender appear to significantly affect MBL, representing important factors to be considered during implant placement.

1 January 2020 in Journal of Oral Science
Verified
Journal Article
Open access
PDF file
Andrea ToffoliAndrea Toffoli
Andrea Toffoli
LPLudovica Parisi
Ludovica Parisi
RTRoberta Tatti
Roberta Tatti
ALAndrea Lorenzi
Andrea Lorenzi
Roberto VerucchiRoberto Verucchi
Roberto Verucchi
GMGuido M. Macaluso
Guido M. Macaluso
Titanium surface characteristics, including microtopography, chemical composition, and wettability, are essential features to achieve osseointegration of dental implants, but the choice of a particular surface topography is still a debated topic among clinicians. An increased level of implant surface hydrophilicity has been demonstrated to ameliorate osseointegration and shorten healing times. The aim of this work is to develop and test a suitable thermal-based method to enhance titanium surface wettability without modifying other characteristics of the implant surface. For this function, titanium discs with different surface topography have been thermally treated by testing different temperatures and excluding those that led to evident chromatic and morphological modifications. The selected surface gain in wettability after the treatment was assessed through contact angle measurement, chemistry modifications through x-ray photoelectron spectroscopy (XPS) analysis, and microtopography through scanning electron microscopy (SEM). Results showed a great enhancement in hydrophilicity on the tested surfaces without any other modification in terms of surface chemical composition and topography. A possible limitation of this method could be the persistent, although relatively slow, biological aging of the surfaces after the treatment. The present findings indicate that the described treatment could be a safe and effective method to enhance dental titanium hydrophilicity and thus its biological performance.