Zoran Vrhovski

Prof. Zoran Vrhovski

Mechatronics, The Bjelovar University of Applied Sciences, Bjelovar, Bjelovarsko-Bilogorska Županija, Croatia
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Zoran VrhovskiZoran Vrhovski
Zoran Vrhovski
KOKarlo Obrovac
Karlo Obrovac
JNJosip Nižetić
Josip Nižetić
AMAlan Mutka
Alan Mutka
Hrvoje KlobučarHrvoje Klobučar
Hrvoje Klobučar
SBStjepan Bogdan
Stjepan Bogdan
Leg Length Discrepancy (LLD) causes a shift of the Center of Mass (CoM) of the human body, as well as an asymmetry in load distribution on the lower extremities. Existing LLD evaluation methods do not take into account this shift in the human body’s CoM. In this paper, a methodology and mechatronic system for the Evaluation and Compensation of LLD for Human Body Balancing are described. The human body’s CoM is measured with two force plates located on two parallel manipulators. Since persons with LLD experience a shift in their CoM, by raising the force plate that is under the shorter leg, the human body can be balanced. For this purpose, the Human Body Balancing Algorithm (HBBA) was proposed and developed. By running the HBBA, the height difference between the force plates under the left and right leg can be measured, which then represents the LLD evaluation. Based on this evaluation, it is possible to design and make a shoe insole which compensates the influence of LLD with the goal of equalizing the load on the legs. A virtual mathematical model of the system was created and the simulation results of the HBBA are presented. The mechatronic system, developed and used to conduct experiments and measurements, is described in detail.

1 March 2012
Verified
Conference Paper
Closed access
GVGoran Vasiljevic
Goran Vasiljevic
Zoran VrhovskiZoran Vrhovski
Zoran Vrhovski
SBStjepan Bogdan
Stjepan Bogdan
We present a non-linear model of a small three wheeled electric car with one rear wheel and two front steered wheels. Each wheel is actuated by a permanent magnet synchronous in-wheel motor. The model was created for development and testing of advanced control algorithms for increasing the car's performance and safety. It includes models of electric motor, non-linear tire-road characteristics, longitudinal and lateral dynamics, a realistic suspension system and the option to influence car's weight and its distribution.

1 October 2017
Verified
Conference Paper
Closed access
Zoran VrhovskiZoran Vrhovski
Zoran Vrhovski
KOKarlo Obrovac
Karlo Obrovac
AMAlan Mutka
Alan Mutka
SBStjepan Bogdan
Stjepan Bogdan
This paper presents a system for dynamic measuring of leg length discrepancy (LLD). The system consists of two 3-RPS parallel manipulators with three degrees of freedom. Parallel manipulators have force sensors that determine the patient's center of gravity (COG) displacement. By changing the height of the moving platform of the parallel manipulator, COG returns in its expected position. The difference between the heights of moving platforms equals the amount of LLD. Inverse kinematics of the 3-RPS parallel manipulator was performed. A virtual simulation system was made and tested in MATLAB/Simulink. The paper presents simulation results of the system operation.

1 September 2018 in Tehnicki vjesnik - Technical Gazette
Verified
Journal Article
Open access
PDF file
KOKarlo Obrovac
Karlo Obrovac
PRPero Raos
Pero Raos
TGTomislav Galeta
Tomislav Galeta
JNJosip Nižetić
Josip Nižetić
AMAlan Mutka
Alan Mutka
Zoran VrhovskiZoran Vrhovski
Zoran Vrhovski
This paper is about defining a different novel concept of a simple machine for producing spinal orthosis moulds. Should such a machine be developed, the required functionality with a special emphasis on low price is to be achieved. The...

27 October 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Zoran VrhovskiZoran Vrhovski
Zoran Vrhovski
Goran BenkekGoran Benkek
Goran Benkek
KHKrunoslav Husak
Krunoslav Husak
ISIvan Sekovanić
Ivan Sekovanić
A force plate is a device that measures the ground reaction force caused by a shift in the human body’s center of mass (CoM). Using a controlled change in the human body’s CoM, the human body’s center of pressure (CoP) is shifted in a 2D plane, along with an acceleration of the CoM along the plane perpendicular to the force plate, which allows for a generation of reference values for game control. In this paper, the development and validation of a system for game control based on a force plate are described. The game control system consists of a force plate, an electronic board used for measuring and PC communication via USB, and a PC application for data acquisition, system calibration, and game control. Based on the measured values of the player’s CoP and the CoM acceleration along a plane perpendicular to the force plate, the game control system simulates pressing the UP, DOWN, RIGHT, LEFT, and SPACE keyboard keys or moving the mouse and clicking the left mouse button, which allows players to control simple games. A mathematical model has been developed for the game control system which includes running system calibration procedures in the system for each individual player. The mechatronic game control system is described in detail, and experiments were run on said system for the purpose of system validation.

1 June 2018
Verified
Conference Paper
Closed access
Zoran VrhovskiZoran Vrhovski
Zoran Vrhovski
Goran BenkekGoran Benkek
Goran Benkek
AMAlan Mutka
Alan Mutka
KOKarlo Obrovac
Karlo Obrovac
SBStjepan Bogdan
Stjepan Bogdan
This paper presents a system for compensating for leg length discrepancy (LLD) based on the estimation of the centre of mass of a human body. The system consists of two 3- RPS parallel manipulators with a moving force plate, control and measuring electronics and a graphical user interface (GUI). Force plates are equipped with force sensors that estimate the centre of mass (CoM) of a human body. Patients with LLD have a displaced CoM. By increasing the height of the force plate that measures a greater load, the CoM of a human body returns into the correct position. The height of the force plate is regulated by means of the 3- RPS parallel manipulator. LLD is compensated for by the difference in heights of the force plates. This paper presents the preliminary experimental results of the system for compensating for LLD.