Mustafa F. Mahmood

Mr. Mustafa F. Mahmood

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Mustafa F. MahmoodMustafa F. Mahmood
Mustafa F. Mahmood
SMSaleem Lateef Mohammed
Saleem Lateef Mohammed
Sadik GharghanSadik Gharghan
Sadik Gharghan
Ali Al-NajiAli Al-Naji
Ali Al-Naji
Javaan ChahlJavaan Chahl
Javaan Chahl
Most wearable intelligent biomedical sensors are battery-powered. The batteries are large and relatively heavy, adding to the volume of wearable sensors, especially when implanted. In addition, the batteries have limited capacity, requiring periodic charging, as well as a limited life, requiring potentially invasive replacement. This paper aims to design and implement a prototype energy harvesting technique based on wireless power transfer/magnetic resonator coupling (WPT/MRC) to overcome the battery power problem by supplying adequate power for a heart rate sensor. We optimized transfer power and efficiency at different distances between transmitter and receiver coils. The proposed MRC consists of three units: power, measurement, and monitoring. The power unit included transmitter and receiver coils. The measurement unit consisted of an Arduino Nano microcontroller, a heart rate sensor, and used the nRF24L01 wireless protocol. The experimental monitoring unit was supported by a laptop to monitor the heart rate measurement in real-time. Three coil topologies: spiral–spiral, spider–spider, and spiral–spider were implemented for testing. These topologies were examined to explore which would be the best for the application by providing the highest transfer power and efficiency. The spiral–spider topology achieved the highest transfer power and efficiency with 10 W at 87%, respectively over a 5 cm air gap between transmitter and receiver coils when a 200 Ω resistive load was considered. Whereas, the spider–spider topology accomplished 7 W and 93% transfer power and efficiency at the same airgap and resistive load. The proposed topologies were superior to previous studies in terms of transfer power, efficiency and distance.

Mustafa F. MahmoodMustafa F. Mahmood
Mustafa F. Mahmood
SMSaleem Latteef Mohammed
Saleem Latteef Mohammed
Sadik GharghanSadik Gharghan
Sadik Gharghan
Ultrasonic power transfer (UPT) is a promising method for wireless power transfer technology for low-power medical applications. Most portable or wearable medical devices are battery-powered. Batteries cannot be used for a long time and require periodic charging or replacement. UPT is a candidate technology for solving this problem. In this work, a 40-KHz ultrasound transducer was used to design a new prototype for supplying power to a wearable heart rate sensor for medical application. The implemented system consists of a power unit and heart rate measurement unit. The power unit includes an ultrasonic transmitter and receiver, rectifier, boost converter and super-capacitors. The heart rate measurement unit comprises measurement and monitoring circuits. UPT-based transfer power and efficiency were achieved using 1-, 4- and 8-Farad (F) super-capacitors. At 4 F, the system achieved 69.4% transfer efficiency and 0.318 mW power at 4 cm. In addition, 97% heart rate measurement accuracy was achieved relative to the benchmark device. The heart rate measurements were validated with statistical analysis. Our results show that this work outperforms previous works in terms of transfer power and efficiency with a 4-cm gap between the ultrasound transmitter and receiver.

1 January 2020 in International Journal of Electrical and Electronic Engineering & Telecommunications
Verified
Journal Article
Open access
Mustafa F. MahmoodMustafa F. Mahmood
Mustafa F. Mahmood
SMSaleem Lateef Mohammed
Saleem Lateef Mohammed
SGSadik Kamel Gharghan
Sadik Kamel Gharghan
Many wearable or portable medical devices have limited battery energy. In this paper, a piezoelectric transducer (PZT) was adopted to take advantage of bodyweight to generate power to wearable and implantable medical devices. To confirm the power generated by the PZT, electromyography (EMG) was used to measure the subject’s muscle activity. The proposed system consists of three parts: power, measurement, and monitoring units. The power unit was tested using on 0.25 F, 0.33 F, 0.5 F, and 1 F supercapacitors to explore the best supercapacitor that can supply the measurement unit by power. Based on using PZT, we found that the power unit was able to supply the measurement unit with adequate voltage (i.e., 5 V) for normal operation without system failure. The present system has better performance than state-of-the-art in terms of power and voltage as compared to that in previous studies.

1 March 2020 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
Mustafa F. MahmoodMustafa F. Mahmood
Mustafa F. Mahmood
SMSaleem Lateef Mohammed
Saleem Lateef Mohammed
Sadik GharghanSadik Gharghan
Sadik Gharghan
Many wearables or portable medical devices have limited battery energy. Such batteries cannot operate for a long time and require recharging or periodic replacement. A piezoelectric transducer (PZT), ultrasonic sensor (USS), and magnetic resonator coupling (MRC) are potential technologies for solving this problem, being promising technologies that can be used to generate free power for low-power medical applications. The USS and MRC optimize transfer power, efficiency, and distance between the transmitter and receiver. These three technologies can generate power to wearable and implantable medical devices (IMDs). To validate the proposed PZT, USS, and MRC, we supplied electromyography (EMG) sensor, a heart rate sensor, and oxygen saturation (SpO2) sensor with adequate power to measure the subject’s muscle activity, heart rate (beats per minute, bpm), and SpO2 rate, respectively. The proposed system consists of four parts: power system, measurement part, wireless transmitter, and monitoring part. We found that 5 V could be used for charging 0.25, 0.33, 0.5, and 1 Farad supercapacitors based on the PZT at duration. Furthermore, the 0.25 F supercapacitor was fully charged in 41 min; compared with previous closed-circuit studies, it achieved high power of 197 μW at resistive load 15 kΩ. In addition, USS-based transfer efficiencies and powers could be used with 1, 4, and 8 F supercapacitors. The system had transfer efficiency and power of 69.4% and 0.318 mW, respectively, at 4 cm when 4 F was adopted. Furthermore, the MRC system had transfer efficiency and power of 21.14% and 2.079 W, respectively, at 7 cm at resistive load 70 Ω. Our results show that the PZT, MRC, and USS in the present study outperformed previous works in terms of power generation, transfer power, and efficiency.

1 April 2026 in Engineering Reports
Verified
Journal Article
Open access
Mustafa F. MahmoodMustafa F. Mahmood
Mustafa F. Mahmood
SYSuhair M. Yaseen
Suhair M. Yaseen
SMSaleem Latteef Mohammed
Saleem Latteef Mohammed
This paper describes the design of a working and low‐cost 3D printer with the explicit purpose of creating external medical aids with minimal resources in a setting‐constrained area like Iraq. This work has been motivated by the limited supply of medical grade printers that are commercially available and expensive, importation restrictions, and the growing demand for personalized assistive equipment in rehabilitation and clinical care. This prototype is scientifically tested as opposed to traditional DIY documentation by using dimensional accuracy tests, repeatability, and practical construction of a medical assistive model. The printer was assembled with components that are easily found in the local Iraqi markets, which makes them easy to maintain and economical. It had a build volume of 230 × 230 × 230 mm with a measured dimensional accuracy of about 91% (≤ 0.2 mm per layer) which is acceptable in nonimplantable medical devices. The system was able to generate bespoke splints and exoskeletal components that had predictable structural functioning. The article demonstrates the possibilities of the existing fabrication technologies to help clinical, educational, and research operations in the developing world. It is also a contextualized and practical model of increasing additive manufacturing capacities in the environment where commercial solutions are hard to acquire.

1 December 2022 in International Journal Bioautomation
Verified
Journal Article
Closed access
HJHuda Jameel
Huda Jameel
Mustafa F. MahmoodMustafa F. Mahmood
Mustafa F. Mahmood
SYSuhair Yaseen
Suhair Yaseen
Peristaltic pumps (PPs) are used to pump clean/sterile or exceptionally responsive liquids without tainting them. They are used in haemodialysis and heart-lung machines to circulate blood as a sidestep during medical procedures. The purpose of this research is to design and construct a PP which consists of a three-roller pump, a bubble sensor, a motor drive, a stepper motor, a microcontroller, and a safety unit. The safety unit functions by using the air bubble sensor, which stops the motor in case of bubble insertion. The performance is experimentally tested in terms of average sensitivity, specificity, and accuracy, which are 99%, 99.55%, and 99.33%, respectively. The evaluation is based on the classification models of true positive (TP), false positive (FP), true negative (TN), and false negative (FN). The overall accuracy is about 98.9%, which indicates the high efficiency of the constructed mechanism.