Dobromir Pressyanov

Prof. Dobromir Pressyanov

Faculty of Physics, Sofia University "St. Kliment Ohridski"
orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2009 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
DPDobromir Pressyanov
Dobromir Pressyanov
KMK. Mitev
K. Mitev
SGStrahil Georgiev
Strahil Georgiev
IDI. Dimitrova
I. Dimitrova

1 April 2002 in American Journal of Physics
Verified
Journal Article
Closed access
DPDobromir Pressyanov
Dobromir Pressyanov
In most textbooks on nuclear physics1–3 the set of radioactive decay chain equations is solved analytically for a maximum of three nuclides. The general Bateman solution4 is given as a final result or only with a brief mention of the elaborate recursive procedure needed to obtain it.3 Here, a short method for obtaining the general solution is demonstrated.

1 December 2020 in Physica Medica
Verified
Journal Article
Closed access
RRRuggero Ruggieri
Ruggero Ruggieri
MRMichele Rigo
Michele Rigo
SNStefania Naccarato
Stefania Naccarato
DGDavide Gurrera
Davide Gurrera
VFVanessa Figlia
Vanessa Figlia
FAFilippo Alongi
Filippo Alongi

1 January 2001 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
DPDobromir Pressyanov
Dobromir Pressyanov
JBJ. Buysse
J. Buysse
ADA. Van Deynse
A. Van Deynse
APA. Poffijn
A. Poffijn
GMG. Meesen
G. Meesen

1 January 2004 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
DPDobromir Pressyanov
Dobromir Pressyanov
JBJozef Buysse
Jozef Buysse
APAndré Poffijn
André Poffijn
ADAnnick Van Deynse
Annick Van Deynse
GMGeert Meesen
Geert Meesen

12 February 2022 in Advances in Radiation Oncology
Verified
Journal Article
Open access
SNStefania Naccarato
Stefania Naccarato
MRMichele Rigo
Michele Rigo
RPRoberto Pellegrini
Roberto Pellegrini
PVPeter Voet
Peter Voet
HAHafid Akhiat
Hafid Akhiat
RRRuggero Ruggieri
Ruggero Ruggieri
Adaptive stereotactic body radiation therapy (SBRT) for prostate cancer (PC) by the 1.5 T MR-linac currently requires online planning by an expert user. A fully automated and user-independent solution to adaptive planning (mCycle) of PC-SBRT was compared with user's plans for the 1.5 T MR-linac. Fifty adapted plans on daily magnetic resonance imaging scans for 10 patients with PC treated by 35 Gy (prescription dose [Dp]) in 5 fractions were reoptimized offline from scratch, both by an expert planner (manual) and by mCycle. Manual plans consisted of multicriterial optimization (MCO) of the fluence map plus manual tweaking in segmentation, whereas in mCycle plans, the objectives were sequentially optimized by MCO according to an a-priori assigned priority list. The main criteria for planning approval were a dose ≥95% of the Dp to at least 95% of the planning target volume (PTV), V33.2 (PTV) ≥ 95%, a dose less than the Dp to the hottest cubic centimeter (V35 ≤ 1 cm3) of rectum, bladder, penile bulb, and urethral planning risk volume (ie, urethra plus 3 mm isotropically), and V32 ≤ 5%, V28 ≤ 10%, and V18 ≤ 35% to the rectum. Such dose-volume metrics, plus some efficiency and deliverability metrics, were used for the comparison of mCycle versus manual plans. mCycle plans improved target dose coverage, with V33.2 (PTV) passing on average (±1 SD) from 95.7% (±1.0%) for manual plans to 97.5% (±1.3%) for mCycle plans (P < .001), and rectal dose sparing, with significantly reduced V32, V28, and V18 (P ≤ .004). Although at an equivalent number of segments, mCycle plans consumed moderately more monitor units (+17%) and delivery time (+9%) (P < .001), whereas they were generally faster (–19%) in terms of optimization times (P < .019). No significant differences were found for the passing rates of locally normalized γ (3 mm, 3%) (P = .059) and γ (2 mm, 2%) (P = .432) deliverability metrics. In the offline setting, mCycle proved to be a trustable solution for automated planning of PC-SBRT on the 1.5 T MR-linac. mCycle integration in the online workflow will free the user from the challenging online-optimization task.