Lorenzo Scalise

Prof. Lorenzo Scalise

Università Politecnica delle Marche, department DIISM
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2007 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Lorenzo ScaliseLorenzo Scalise
Lorenzo Scalise
Umberto MorbiducciUmberto Morbiducci
Umberto Morbiducci
The aim of the present work is to establish a protocol for monitoring the cardiac activity measuring the skin surface vibrations of the main neck vessels, caused by vascular wall motion in carotid artery. The method is based on the optical recording of the movements of the neck by means of laser Doppler interferometry. The ECG signal and the velocity of vibration of the skin in correspondence of the carotid artery (named optical vibrocardiography: VCG) have been simultaneously recorded on five healthy subjects. Standard heart rate variability tests have been carried out. The capability of VCG signals to be used as a surrogate of the ECG in assessing both cardiac rate and heart rate variability (HRV) has been tested using time and spectral descriptors, and specific statistical analysis. Mean differences have been found lower than 3.13%. Optical vibrocardiography might be a simple approach to the clinical practice of cardiovascular screening, in particular in harsh environment, such as MR clinical practice, where ECG recordings are corrupted by artefacts and ECG cables might represent an hazard for the patients.

23 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Gloria CosoliGloria Cosoli
Gloria Cosoli
LALuca Antognoli
Luca Antognoli
VVValentina Veroli
Valentina Veroli
Lorenzo ScaliseLorenzo Scalise
Lorenzo Scalise
Nowadays, the use of wearable devices is spreading in different fields of application, such as healthcare, digital health, and sports monitoring. In sport applications, the present trend is to continuously monitor the athletes’ physiological parameters during training or competitions to maximize performance and support coaches. This paper aims to evaluate the performances in heart rate assessment, in terms of accuracy and precision, of both wrist-worn and chest-strap commercial devices used during swimming activity, considering a test population of 10 expert swimmers. Three devices were employed: Polar H10 cardiac belt, Polar Vantage V2, and Garmin Venu Sq smartwatches. The former was used as a reference device to validate the data measured by the two smartwatches. Tests were performed both in dry and wet conditions, considering walking/running on a treadmill and different swimming styles in water, respectively. The measurement accuracy and precision were evaluated through standard methods, i.e., Bland–Altman plot, analysis of deviations, and Pearson’s correlation coefficient. Results show that both precision and accuracy worsen during swimming activity (with an absolute increase of the measurement deviation in the range of 13–56 bpm for mean value and 49–52 bpm for standard deviation), proving how water and arms movement act as relevant interference inputs. Moreover, it was found that wearable performance decreases when activity intensity increases, highlighting the need for specific research for wearable applications in water, with a particular focus on swimming-related sports activities.

17 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Andrea MonteriùAndrea Monteriù
Andrea Monteriù
Mariorosario PristMariorosario Prist
Mariorosario Prist
Emanuele FrontoniEmanuele Frontoni
Emanuele Frontoni
SLSauro Longhi
Sauro Longhi
FPFilippo Pietroni
Filippo Pietroni
Gian Marco RevelGian Marco Revel
Gian Marco Revel
Smart homes play a strategic role for improving life quality of people, enabling to monitor people at home with numerous intelligent devices. Sensors can be installed to provide a continuous assistance without limiting the resident’s daily routine, giving her/him greater comfort, well-being and safety. This paper is based on the development of domestic technological solutions to improve the life quality of citizens and monitor the users and the domestic environment, based on features extracted from the collected data. The proposed smart sensing architecture is based on an integrated sensor network to monitor the user and the environment to derive information about the user’s behavior and her/his health status. The proposed platform includes biomedical, wearable, and unobtrusive sensors for monitoring user’s physiological parameters and home automation sensors to obtain information about her/his environment. The sensor network stores the heterogeneous data both locally and remotely in Cloud, where machine learning algorithms and data mining strategies are used for user behavior identification, classification of user health conditions, classification of the smart home profile, and data analytics to implement services for the community. The proposed solution has been experimentally tested in a pilot study based on the development of both sensors and services for elderly users at home.

16 March 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Sara CasacciaSara Casaccia
Sara Casaccia
Luca RomeoLuca Romeo
Luca Romeo
ACAndrea Calvaresi
Andrea Calvaresi
NMNicole Morresi
Nicole Morresi
Andrea MonteriùAndrea Monteriù
Andrea Monteriù
Gian Marco RevelGian Marco Revel
Gian Marco Revel
This paper proposes a specific domotic sensor network to measure the well-being of elderly people in private home environments through Machine Learning (ML) algorithms trained with daily surveys. The tests have been conducted in 5 apartments lived by 8 older people where the non-obtrusive sensor network is installed. Two ML algorithms are compared, Random Forest (RF) and Regression Tree (RT), such that to verify whether the users’ well-being is encoded in behavioural patterns obtained from the domotic data. These data are used to measure users’ well-being and compared with three reference indices obtained through a daily survey: a physical (Phy), a mental (Mind) and a general health index (Avg). The extracted indices from the daily survey are used to train ML algorithms in the estimation of user’s well-being for users that live alone (single-resident) or with others (multi-resident). Single-house and multi-house procedures are tested, both to extract a user-specific behaviour, and assess whether the model is able to generalise across different users and environments. Results show that the RF algorithm provides better performance than the RT algorithm in predicting the level of well-being with a Mean Absolute Error in the multi-house procedure of 32%, 13% and 17% for the Avg, Mind and Phy indices, respectively.

11 March 2016 in Psychophysiology
Verified
Journal Article
Closed access
PDF file
ESErik J. Sirevaag
Erik J. Sirevaag
SCSara Casaccia
Sara Casaccia
EREdward A. Richter
Edward A. Richter
JOJoseph A. O'Sullivan
Joseph A. O'Sullivan
Lorenzo ScaliseLorenzo Scalise
Lorenzo Scalise
JRJohn W. Rohrbaugh
John W. Rohrbaugh

18 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
LALuca Antognoli
Luca Antognoli
Sara MocciaSara Moccia
Sara Moccia
LMLucia Migliorelli
Lucia Migliorelli
Sara CasacciaSara Casaccia
Sara Casaccia
Lorenzo ScaliseLorenzo Scalise
Lorenzo Scalise
Emanuele FrontoniEmanuele Frontoni
Emanuele Frontoni
Background: Heartbeat detection is a crucial step in several clinical fields. Laser Doppler Vibrometer (LDV) is a promising non-contact measurement for heartbeat detection. The aim of this work is to assess whether machine learning can be used for detecting heartbeat from the carotid LDV signal. Methods: The performances of Support Vector Machine (SVM), Decision Tree (DT), Random Forest (RF) and K-Nearest Neighbor (KNN) were compared using the leave-one-subject-out cross-validation as the testing protocol in an LDV dataset collected from 28 subjects. The classification was conducted on LDV signal windows, which were labeled as beat, if containing a beat, or no-beat, otherwise. The labeling procedure was performed using electrocardiography as the gold standard. Results: For the beat class, the f1-score (f1) values were 0.93, 0.93, 0.95, 0.96 for RF, DT, KNN and SVM, respectively. No statistical differences were found between the classifiers. When testing the SVM on the full-length (10 min long) LDV signals, to simulate a real-world application, we achieved a median macro-f1 of 0.76. Conclusions: Using machine learning for heartbeat detection from carotid LDV signals showed encouraging results, representing a promising step in the field of contactless cardiovascular signal analysis.