Monitoring of patients with inherited metabolic disorders (IMDs) using dried blood spot (DBS) specimens has been routinely used since the inception of newborn screening (NBS) for phenylketonuria in the 1960s. The introduction of flow injection analysis tandem mass spectrometry (FIA–MS/MS) in the 1990s facilitated the expansion of NBS for IMDs. This has led to increased identification of patients who require biochemical monitoring. Monitoring of IMD patients using DBS specimens is widely favoured due to the convenience of collecting blood from a finger prick onto filter paper devices in the patient’s home, which can then be mailed directly to the laboratory. Ideally, analytical methodologies with a short analysis time and high sample throughput are required to enable results to be communicated to patients in a timely manner, allowing prompt therapy adjustment. The development of ultra-performance liquid chromatography (UPLC–MS/MS), means that metabolic laboratories now have the capability to routinely analyse DBS specimens with superior specificity and sensitivity. This advancement in analytical technology has led to the development of numerous assays to detect analytes at low concentrations (pmol/L) in DBS specimens that can be used to monitor IMD patients. In this review, we discuss the pre-analytical, analytical and post-analytical variables that may affect the final test result obtained using DBS specimens used for monitoring of patients with an IMD.
In 1963, Robert Guthrie’s pioneering work developing a bacterial inhibition assay to measure phenylalanine in dried blood spots, provided the means for whole-population screening to detect phenylketonuria in the USA. In the following decades, NBS became firmly established as a part of public health in developed countries. Technological advances allowed for the addition of new disorders into routine programmes and thereby resulted in a paradigm shift. Today, technological advances in immunological methods, tandem mass spectrometry, PCR techniques, DNA sequencing for mutational variant analysis, ultra-high performance liquid chromatography (UPLC), iso-electric focusing, and digital microfluidics are employed in the NBS laboratory to detect more than 60 disorders. In this review, we will provide the current state of methodological advances that have been introduced into NBS. Particularly, ‘second-tier’ methods have significantly improved both the specificity and sensitivity of testing. We will also present how proteomic and metabolomic techniques can potentially improve screening strategies to reduce the number of false-positive results and improve the prediction of pathogenicity. Additionally, we discuss the application of complex, multiparameter statistical procedures that use large datasets and statistical algorithms to improve the predictive outcomes of tests. Future developments, utilizing genomic techniques, are also likely to play an increasingly important role, possibly combined with artificial intelligence (AI)-driven software. We will consider the balance required to harness the potential of these new advances whilst maintaining the benefits and reducing the risks for harm associated with all screening.
9 September 2008 in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
Background: Creatine plays an important role in the storage and transmission of phosphate-bound energy. The cerebral creatine deficiency syndromes (CCDS) comprise three inherited defects in creatine biosynthesis and transport. They are characterized by mental retardation, speech and language delay and epilepsy. All three disorders cause low-creatine signal on brain magnetic resonance spectroscopy (MRS); however, MRS may not be readily available and even when it is, biochemical tests are required to determine the underlying disorder. Methods: Analysis was performed by liquid chromatography-tandem mass spectrometry in positive ionization mode. Samples were analysed underivatized using a rapid ‘dilute and shoot’ approach. Chromatographic separation of the three compounds was achieved. Stable isotope internal standards were used for quantification. Results: Creatine, creatinine and guanidinoacetate were measured with a 2.5 minute run time. For guanidinoacetate, the standard curve was linear to at least 5000 μmol/L and for creatine and creatinine it was linear to at least 25 mmol/L. The lower limit of quantitation was 0.4 μmol/L for creatine and guanidinoacetate and 0.8 μmol/L for creatinine. Recoveries ranged from 86% to 106% for the three analytes. Intra- and inter-assay variation for each analyte was <10% in both urine and plasma. Conclusion: A tandem mass spectrometric method has been developed and validated for the underivatized determination of guanidinoacetate, creatine and creatinine in human urine and plasma. Minimal sample preparation coupled with a rapid run time make the method applicable to the routine screening of patients with suspected CCDS.
21 August 2019 in Journal of Inherited Metabolic Disease
Measurement of dried blood spot (DBS) phenylalanine (Phe) is central to the monitoring of patients with phenylketonuria. However, the volume and hematocrit (Hct) of the blood applied to conventional DBS cards significantly affects analytical results. Volumetric blood collection devices are reported to be more accurate, precise and less prone to Hct effects. Accuracy, imprecision, effect of blood volume and Hct were evaluated for measurement of Phe and tyrosine using three volumetric devices and compared with the conventional PerkinElmer-226 filter-paper collection devices. i.e. conventional DBS cards. Applicability for use in a clinical laboratory was assessed qualitatively. Blood volume did not impact on the performance of the volumetric devices; however, significant biases were observed with the conventional DBS card. A higher Hct introduced unacceptable bias for Neoteryx-Mitra and conventional DBS card. All devices had a mean relative standard deviation (RSD) ≤ 4.1 %, except for the Neoteryx-Mitra (≤ 6.2 %). Relative to liquid blood, the mean biases of Phe for the various devices were -5.1 (HemaXis-DB10), -7.8 (Capitainer-qDBS), -12.0 (Neoteryx-Mitra) and -32.6 % (conventional DBS card). Introducing volumetric collection devices will overcome the significant pre-analytical issues associated with conventional DBS collection and improve the biochemical monitoring of patients with PKU.
1 July 2000 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms