Christof Roosli

Dr. Christof Roosli

University Hospital Zurich, Zurich, Switzerland
+1
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Hearing Research
Verified
Journal Article
Open access
IDIvo Dobrev
Ivo Dobrev
JSJae Hoon Sim
Jae Hoon Sim
SSStefan Stenfelt
Stefan Stenfelt
SISebastian Ihrle
Sebastian Ihrle
RGRahel Gerig
Rahel Gerig
CRChristof Roosli
Christof Roosli
Bone conduction (BC) is an alternative to air conduction to stimulate the inner ear. In general, the stimulation for BC occurs on a specific location directly on the skull bone or through the skin covering the skull bone. The stimulation propagates to the ipsilateral and contralateral cochlea, mainly via the skull bone and possibly via other skull contents. This study aims to investigate the wave propagation on the surface of the skull bone during BC stimulation at the forehead and at ipsilateral mastoid. Measurements were performed in five human cadaveric whole heads. The electro-magnetic transducer from a BCHA (bone conducting hearing aid), a Baha® Cordelle II transducer in particular, was attached to a percutaneously implanted screw or positioned with a 5-Newton steel headband at the mastoid and forehead. The Baha transducer was driven directly with single tone signals in the frequency range of 0.25-8 kHz, while skull bone vibrations were measured at multiple points on the skull using a scanning laser Doppler vibrometer (SLDV) system and a 3D LDV system. The 3D velocity components, defined by the 3D LDV measurement coordinate system, have been transformed into tangent (in-plane) and normal (out-of-plane) components in a local intrinsic coordinate system at each measurement point, which is based on the cadaver head's shape, estimated by the spatial locations of all measurement points. Rigid-body-like motion was dominant at low frequencies below 1 kHz, and clear transverse traveling waves were observed at high frequencies above 2 kHz for both measurement systems. The surface waves propagation speeds were approximately 450 m/s at 8 kHz, corresponding trans-cranial time interval of 0.4 ms. The 3D velocity measurements confirmed the complex space and frequency dependent response of the cadaver heads indicated by the 1D data from the SLDV system. Comparison between the tangent and normal motion components, extracted by transforming the 3D velocity components into a local coordinate system, indicates that the normal component, with spatially varying phase, is dominant above 2 kHz, consistent with local bending vibration modes and traveling surface waves. Both SLDV and 3D LDV data indicate that sound transmission in the skull bone causes rigid-body-like motion at low frequencies whereas transverse deformations and travelling waves were observed above 2 kHz, with propagation speeds of approximately of 450 m/s at 8 kHz.

1 July 2019 in Hearing Research
Verified
Journal Article
Open access
IDIvo Dobrev
Ivo Dobrev
JSJae Hoon Sim
Jae Hoon Sim
FPFlurin Pfiffner
Flurin Pfiffner
AHAlexander Huber
Alexander Huber
CRChristof Roosli
Christof Roosli
Investigation of bone conduction sound propagation by osseous and non-osseous pathways and their interactions based upon the stimulation site and coupling method of the actuator from a bone conduction hearing aid (BCHA). Experiments were conducted on five Thiel embalmed whole head cadaver specimens. The electromagnetic actuator from a commercial bone conduction hearing aid (BCHA) (Baha® Cordelle II) was used to provide a stepped sine stimulus in the range of 0.1-10 kHz. Osseous pathways (direct bone stimulation or transcutaneous stimulation) were sequentially activated by stimulation at the mastoid or the BAHA side using several methods including a percutaneously implanted screw, Baha® Attract transcutaneous magnet and a 5-N (5-N) steel headband. Non-osseous pathways (only soft tissue or intra-cranial contents) were activated by actuator stimulation on the eye or neck via attachment to a 5-N steel headband, and were compared with stimulation via equivalent attachment on the mastoid and forehead. The response of the skull was measured as motions of the ipsi- and contralateral promontory and intracranial pressure (ICP) in the central, anterior, posterior, ipsilateral and contralateral temporal regions of the cranial space. Promontory motion was monitored using a 3-dimensional Laser Doppler vibrometer (3D LDV) system. The promontory undergoes spatially complex motion with similar contributions from all motion components, regardless of stimulation mode. Combined 3D promontory motion provided lower inter-sample variability than did any individual component. Transcranial transmission showed gain for the low frequencies and attenuation above 1 kHz, independent of stimulation mode This effect was not only for the magnitude but also its spatial composition such that contralateral promontory motion did not follow the direction of ipsilateral stimulation above 0.5 kHz. Non-osseous stimulation on the neck and eye induced comparable ICP relative to percutaneous (via screw) mastoid stimulation. Corresponding phase data indicated lower phase delays for ICP when stimulation was via non-osseous means (i.e., to the eye) versus osseous means (i.e., to the mastoid or forehead). Sound propagation due to skull stimulation passes through the thicker bony sections first before activating the CSF. Utilization of 3D promontory motion measurements provides more precise (lower inter-sample variability) information about bone vibrations than does any individual component. It also provides a more detailed description of transcranial attenuation. A comprehensive combination of motion and pressures measurements across the head, combined with a variation of the stimulation condition, could reveal details about sound transmission within the skull.

23 February 2009 in The Laryngoscope
Verified
Journal Article
Closed access
PDF file
CRChristof Roosli
Christof Roosli
DTDominique C. Tschudi
Dominique C. Tschudi
GSGabriela Studer
Gabriela Studer
JBJulia Braun
Julia Braun
SSSandro J. Stoeckli
Sandro J. Stoeckli

1 December 2009 in Head & Neck
Verified
Journal Article
Closed access
PDF file
CRChristof Roosli
Christof Roosli
GSGabriela Studer
Gabriela Studer
SSSandro J. Stoeckli
Sandro J. Stoeckli

1 August 2013 in Otology & Neurotology
Verified
Journal Article
Closed access
CRChristof Roosli
Christof Roosli
JSJae Hoon Sim
Jae Hoon Sim
HMHendrik Möckel
Hendrik Möckel
MMMarkus Mokosch
Markus Mokosch
RPRudolf Probst
Rudolf Probst
OBJECTIVE: Description and evaluation of a newly developed artificial temporal bone (TB) model suitable for surgical training for cochlear implantation.\ud \ud SUBJECT: Based on micro-computed tomographic images, a TB model was designed with material properties as similar to bone as possible. The bony anatomic details were rebuilt as closely as possible with preservation of the endocochlear lumen.\ud \ud INTERVENTION: The TB model was compared with a human cadaveric TB by 8 otologists experienced in cochlear implantation.\ud \ud MAIN OUTCOME MEASURE: The otologists were asked to respond to a semiquantitative questionnaire with scales from 1 (strongly disagree) to 5 (strongly agree). Anatomic details were compared macroscopically and microscopically. The surgical steps of mastoidectomy, posterior tympanotomy, cochleostomy, and insertion of a cochlear electrode were assessed.\ud \ud RESULTS: The material properties and anatomic details of the TB model were generally comparable to the human TB. One exception was the round window membrane, which was not modeled appropriately. The surgical steps, including the insertion of the electrode, were rated as comparable.\ud \ud CONCLUSION: The TB model is suitable for surgical training for interventions such as cochlear implantation. It cannot replace cadaveric human temporal bones completely, but it provides an easily available alternative to train and develop surgical skills. A wider variety of anatomic models, such as an infant's TB or malformations, will increase the value of TB models

1 December 2018 in Hearing Research
Verified
Journal Article
Open access
IDIvo Dobrev
Ivo Dobrev
JSJae Hoon Sim
Jae Hoon Sim
FPFlurin Pfiffner
Flurin Pfiffner
AHAlexander Huber
Alexander Huber
CRChristof Roosli
Christof Roosli
Evaluation of the transfer function efficiency of a newly-developed piezo-electric actuator for active subcutaneous bone conduction hearing aid. The experiments were conducted on four Thiel embalmed whole head cadaver specimens. A novel actuator based on piezo-electric transduction (PZTA), part of a subcutaneous bone conduction hearing aid device, was sequentially implanted on three locations: 1) Immediately posterior to pinna; 2) 50-60 mm posterior to pinna, approximately the same distance as between the BAHA (bone anchored hearing aid) location and the ear canal, but the same horizontal level as location 1; 3) the traditional BAHA location. Using a single point 3-dimensional laser Doppler vibrometer (LDV) system, three types of motion measurements were performed at the cochlear promontory for each stimulation location: 1) ipsilateral side, 2) contralateral side, 3) measurements 1 and 2 were repeated after mastoidectomy on the ipsilateral side. On average, stimulation at locations 1 and 2 show a trend for higher promontory motion relative to location 3 (BAHA location) above 1 kHz. Stimulation at location 1 had an average improvement of 1-6 dB at 2-4 kHz, and 1-18 dB at 6-8 kHz. The spatial composition of the motion showed significant contributions from both in-plane and out-of-plane (along ear canal) motion components, with in-plane components being dominant at mid and high frequencies for locations 2 and 3. Stimulation at locations 1 and 3 produced similar transcranial attenuation at mid frequencies (0.6-4 kHz), with a potential trend of higher attenuation (seen in 3 or the 4 samples) for location 1 at higher frequencies (>4 kHz). The mastoidectomy affected negatively mostly the high frequencies (6-8 kHz) for stimulation at location 1, with no significant change for location 3. The sound transfer function efficacy of a novel subcutaneous bone conduction device has been quantified, and the influence of stimulation location and mastoidectomy have been analyzed based on promontory motion in Thiel-preserved cadaver heads.