Frank Vollmer

Prof. Dr. Frank Vollmer

Department of Physics & Astronomy, University of Exeter, Exeter, UK

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2008 in Nature Methods
Verified
Journal Article
Closed access
FVFrank Vollmer
Frank Vollmer
SAStephen Arnold
Stephen Arnold

22 May 2015 in Advances in Optics and Photonics
Verified
Journal Article
Closed access
PDF file
Matthew R. ForemanMatthew R. Foreman
Matthew R. Foreman
JSJon D. Swaim
Jon D. Swaim
FVFrank Vollmer
Frank Vollmer
We present a comprehensive overview of sensor technology exploiting optical whispering gallery mode (WGM) resonances. After a short introduction we begin by detailing the fundamental principles and theory of WGMs in optical microcavities and the transduction mechanisms frequently employed for sensing purposes. Key recent theoretical contributions to the modeling and analysis of WGM systems are highlighted. Subsequently we review the state of the art of WGM sensors by outlining efforts made to date to improve current detection limits. Proposals in this vein are numerous and range, for example, from plasmonic enhancements and active cavities to hybrid optomechanical sensors, which are already working in the shot noise limited regime. In parallel to furthering WGM sensitivity, efforts to improve the time resolution are beginning to emerge. We therefore summarize the techniques being pursued in this vein. Ultimately WGM sensors aim for real-world applications, such as measurements of force and temperature, or alternatively gas and biosensing. Each such application is thus reviewed in turn, and important achievements are discussed. Finally, we adopt a more forward-looking perspective and discuss the outlook of WGM sensors within both a physical and biological context and consider how they may yet push the detection envelope further.

27 May 2002 in Applied Physics Letters
Verified
Journal Article
Closed access
FVFrank Vollmer
Frank Vollmer
DBD. Braun
D. Braun
ALA. Libchaber
A. Libchaber
MKM. Khoshsima
M. Khoshsima
ITI. Teraoka
I. Teraoka
SAS. Arnold
S. Arnold
We present an optical biosensor with unprecedented sensitivity for detection of unlabeled molecules. Our device uses optical resonances in a dielectric microparticle (whispering gallery modes) as the physical transducing mechanism. The resonances are excited by evanescent coupling to an eroded optical fiber and detected as dips in the light intensity transmitted through the fiber at different wavelengths. Binding of proteins on the microparticle surface is measured from a shift in resonance wavelength. We demonstrate the sensitivity of our device by measuring adsorption of bovine serum albumin and we show its use as a biosensor by detecting streptavidin binding to biotin.

30 December 2008 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
FVFrank Vollmer
Frank Vollmer
SAS. Arnold
S. Arnold
DKD. Keng
D. Keng
We report the label-free, real-time optical detection of Influenza A virus particles. Binding of single virions is observed from discrete changes in the resonance frequency/wavelength of a whispering-gallery mode excited in a microspherical cavity. We find that the magnitude of the discrete wavelength-shift signal can be sufficiently enhanced by reducing the microsphere size. A reactive sensing mechanism with inverse dependence on mode volume is confirmed in experiments with virus-sized polystyrene nanoparticles. By comparing the electromagnetic theory for this reactive effect with experiments, the size and mass (≈5.2 × 10 −16 g) of a bound virion are determined directly from the optimal resonance shift.

15 February 2003 in Optics Letters
Verified
Journal Article
Closed access
PDF file
SAS. Arnold
S. Arnold
MKM. Khoshsima
M. Khoshsima
ITI. Teraoka
I. Teraoka
Stephen HollerStephen Holler
Stephen Holler
FVFrank Vollmer
Frank Vollmer
Biosensors based on the shift of whispering-gallery modes in microspheres accompanying protein adsorption are described by use of a perturbation theory. For random spatial adsorption, theory predicts that the shift should be inversely proportional to microsphere radius R and proportional to protein surface density and excess polarizability. Measurements are found to be consistent with the theory, and the correspondence enables the average surface area occupied by a single protein to be estimated. These results are consistent with crystallographic data for bovine serum albumin. The theoretical shift for adsorption of a single protein is found to be extremely sensitive to the target region, with adsorption in the most sensitive region varying as 1/R5/2. Specific parameters for single protein or virus particle detection are predicted.

31 August 2014 in Nature Nanotechnology
Verified
Journal Article
Closed access
MBMartin D. Baaske
Martin D. Baaske
Matthew R. ForemanMatthew R. Foreman
Matthew R. Foreman
FVFrank Vollmer
Frank Vollmer