Amin Fatoni

Prof. Dr. Amin Fatoni

Universitas Jenderal Soedirman
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2013 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
AFAmin Fatoni
Amin Fatoni
ANApon Numnuam
Apon Numnuam
PKProespichaya Kanatharana
Proespichaya Kanatharana
WLWarakorn Limbut
Warakorn Limbut
CTChongdee Thammakhet
Chongdee Thammakhet
PTPanote Thavarungkul
Panote Thavarungkul

22 September 2014 in The Analyst
Verified
Journal Article
Closed access
PDF file
AFAmin Fatoni
Amin Fatoni
ANApon Numnuam
Apon Numnuam
PKProespichaya Kanatharana
Proespichaya Kanatharana
WLWarakorn Limbut
Warakorn Limbut
PTPanote Thavarungkul
Panote Thavarungkul
A novel highly sensitive and selective molecularly imprinted polymer (MIP) cryogel biosensor for determination of microalbumin in urine samples was fabricated. The MIP gel was prepared based on the graft copolymerization of acrylamide with N,N′-methylenebisacrylamide on chitosan using human serum albumin (HSA) as the template. The sub-zero polymerization allowed the solvent to form ice crystals and left a macroporous cryogel structure when it was thawed. After removing the template, the specific imprinted surface on cryogel pore walls was used to detect HSA via a redox mediator (ferrocene), entrapped in the cryogel, using differential pulse voltammetry (DPV). The electrochemical detection was improved by the presence of graphene that has been composited within the polymer. For determination of albumin, the fabricated MIP cryogel biosensor showed a high sensitivity with a wide linear range of 1.0 × 10−4 to 1.0 × 101 mg L−1 and a low limit of detection of 5.0 × 10−5 mg L−1 (S/N = 3). The sensor also provided a very good reusability, i.e., the sensitivity remained >90% after 9 cycles of binding–rewashing (18 analyses per cycle), while the sensitivity only decreased to 90% after 6 weeks of storage at room temperature. The biosensor also showed a good selectivity, both against bovine serum albumin (BSA) and some common possible interfering compounds normally present in urine (ascorbic acid, uric acid, urea, sodium, chloride, potassium and creatinine). The excellent performance of the biosensor was confirmed by analyzing microalbumin in urine samples, and results were in good agreement with those obtained by the standard immunoturbidimetric method (P > 0.05).

1 June 2014 in Electrochimica Acta
Verified
Journal Article
Closed access
AFAmin Fatoni
Amin Fatoni
ANApon Numnuam
Apon Numnuam
PKProespichaya Kanatharana
Proespichaya Kanatharana
WLWarakorn Limbut
Warakorn Limbut
PTPanote Thavarungkul
Panote Thavarungkul

5 February 2016 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
AFAmin Fatoni
Amin Fatoni
DDDian Windy Dwiasi
Dian Windy Dwiasi
DHDadan Hermawan
Dadan Hermawan
Cryogel is macroporous structure provides a large surface area for biomolecule immobilization. In this work, an alginate cryogel based biosensor was developed to detect glucose. The cryogel was prepared using alginate cross-linked by calcium chloride under subzero temperature. This porous structure was growth in a 100 L micropipette tip with a glucose oxidase enzyme entrapped inside the cryogel. The glucose detection was based on the colour change of redox indicator, potassium permanganate, by the hydrogen peroxide resulted from the conversion of glucose. The result showed a porous structure of alginate cryogel with pores diameter of 20-50 µm. The developed glucose biosensor was showed a linear response in the glucose detection from 1.0 to 5.0 mM with a regression of y = 0.01x+0.02 and R 2 of 0.994. Furthermore, the glucose biosensor was showed a high operational stability up to 10 times of uninterrupted glucose detections.

17 December 2021 in Gels
Verified
Journal Article
Open access
PDF file
AFAmin Fatoni
Amin Fatoni
AWAziz Wijonarko
Aziz Wijonarko
MAMekar Dwi Anggraeni
Mekar Dwi Anggraeni
DHDadan Hermawan
Dadan Hermawan
HDHartiwi Diastuti
Hartiwi Diastuti
ZUZusfahair
Zusfahair
Glucose biosensors based on porous material of alginate cryogel has been developed, and the cryogel provides a large surface area for enzyme immobilization. The alginate cryogel has been supplemented with NiFe2O4 nanoparticles to improve the electron transfer for electrochemical detection. The fabrication parameters and operational conditions for the biosensor have also been optimized. The results showed that the optimum addition of NiFe2O4 nanoparticles to the alginate solution was 0.03 g/mL. The optimum operational conditions for the electrochemical detection were a cyclic voltammetry scan rate of 0.11 V/s, buffer pH of 7.0, and buffer concentration of 150 mM. The fabricated alginate NiFe2O4 nanoparticles cryogel-based glucose biosensor showed a linear response for glucose determination with a regression line of y = 18.18x + 455.28 and R² = 0.98. Furthermore, the calculated detection limit was 0.32 mM and the limit of quantification was 1.06 mM.

1 January 2016 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
AFAmin Fatoni
Amin Fatoni
MAMekar Dwi Anggraeni
Mekar Dwi Anggraeni
DDDian Windy Dwiasi
Dian Windy Dwiasi
Large surface area of porous structure cryogel showed an excellent matrix for enzyme immobilization, especially in the biosensor development. A chitosan cryogel beads was prepare by cross-linking chitosan with sodium tripolyphosphate at subzero temperature. This chitosan cryogel beads was then used to immobilize glucose oxidase for glucose biosensor fabrication. The biosensor was simple design and operation, using a micropipette tip to hold the immobilized enzyme, where the reaction can be performed by suck-hold-release the analyte using micropipette. The detection was based on the reaction between hydrogen peroxide, enzymatic product, with titanium (IV) oxysulfate to produce color change, which finally recorded using commercial scanner. The digital image obtained was then analyze using freeware of ImageJ to get the relationship between color change and the analyte concentration. The result showed a linear response in the glucose detection of 1.0 to 5.0 and 10 mM, with a regression of y = 11.33x + 46.02 and R2 of 0.983. The great enzyme immobilization was showed in the fabricated biosensor with 12 times uninterrupted analysis without reducing significant responses.