The introduction of parametric tools has made a strong shift within a traditional approach to urban planning and building design, including the creation of a design awareness zone where environmental issues are concerned. This approach also uses sufficient data to be used already at the concept stage and provides initial interdisciplinary solutions. Analyses from the very initial stages allow the inclusion of smart energy choices influencing the massing, architectural features, proportions, flexibility of design, and economics. This is only a threshold; there is still a place for further development and more accurate analyses leading to the construction of buildings and urban areas with a stronger input of sustainable solutions, as existing approaches have certain limitations. This path has been followed in several research grants conducted at the Faculty of Architecture Warsaw University of Technology, and later on developed as a co-operation area with various stakeholders. Outside the general state of art, this paper will include two case studies which were provided as a concept design for prospective investors. Both locations are in the Warsaw Downtown Area, and analyses include algorithmic models dealing with the optimisation of the buildings’ forms, urban scale sun radiation levels, shadow and wind analyses indicating use of sunlight energy and wind as alternative energy sources. One of the case studies contains Pareto Front including both single- and multi-criteria optimization methods for analysing energy and economic efficiency issues, pointing out the best case solutions.
This article concerns the Life Cycle Assessment method of evaluation and the ways in which it can be applied as a tool facilitating the design of buildings to reduce embodied energy and embodied carbon. Three variants of a building were examined with the same functional ground plan and usable floor area of 142.6 m2. Each variant of the building was designed using different construction technologies: bricklaying technology utilizing autoclaved aerated concrete popular in Poland, wooden frame insulated with mineral wool, and the Straw-bale technology. Using digital models (Building Information Model) the building’s energy characteristics was simulated and the embodied energy and embodied carbon of the production stage (also called cradle-to-gate) were calculated. The performed calculations were used to compare the cumulative energy and embodied carbon of each variant for a 40 year long life cycle.
There is a growing interest in low-tech technologies, drawing on the tradition of building with organic and unprocessed materials. One such technology is straw bale constructions. This paper presents an example of a timber-frame building in which straw bales were used as wall filling. The building is located in northern Poland and is a small, year-round single-family dwelling. Based on the available literature and experimental studies, it can be concluded that straw bale technology carries several potential threats related to the selected technology, quality of workmanship, and climatic conditions. The article describes the measurements of the air tightness of the building, the heat transfer coefficient U and the analysis of the humidity of straw walls. The study results confirm the risks related to the low air tightness of the building and the risk of water vapour condensation in the external partitions.
This study aims to evaluate the potential of circular economy principles in earth-based construction using an experimental rammed earth building located in Pasłęk, Poland as a case study. The research focuses on end-of-life scenarios for earth materials, with particular emphasis on rammed earth, adobe, and compressed earth blocks stabilized with Portland cement. A scenario-based life-cycle assessment (LCA) was conducted to compare alternative demolition and reuse strategies, including manual and mechanical deconstruction, as well as on-site and off-site material reuse. Greenhouse gas emissions associated with demolition (Module C1) and transport (Module C2) were estimated for each scenario. The results indicate that manual deconstruction combined with local, on-site reuse leads to the lowest carbon footprint, whereas off-site reuse involving long-distance transport significantly increases greenhouse gas emissions. In addition, qualitative reuse pathways were identified for wood, glass, ceramics, and insulation materials. The study reveals a lack of standardized technical procedures for the recovery and reuse of stabilized earthen materials after demolition and highlights the importance of integrating end-of-life planning into the early design phase using digital tools such as material passports and BIM. The findings demonstrate that properly designed rammed earth systems can provide a viable low-tech solution for reducing construction waste and supporting circular material flows in the built environment.
The problem of heat storage in low- or ultra-low-energy houses is becoming a crucial issue. The general purpose of this study was to determine the potential for utilising heat gain recovery in a building. The proposed solution is based on an auxiliary latent heat storage tank using paraffin RT24. The tank is connected to an integrated heat recovery system that supplies heat from the internal loop of a mechanical ventilation system. The storage capacity of the tank was determined using the proposed parameter “excess of heat gains” of the thermal zone, and was obtained by measurement. The detailed construction of the tank, the phase change material properties and the quantity were proposed. The data that was collected allowed for the calculation of the temporary charging level as well as the overall seasonal energy stored in the tank. It was shown that during the heating season, the temperature could rise above the set-up value of 20 °C by as much as 8 K at maximum. Although the analysed building was characterised by heavy construction and high thermal mass, the additional heat could be effectively stored and utilised to cover the energy demand of the zone at the level of 88 MJ/a and 208 MJ/a, depending on the airflow rate between the rooms and the heat exchanger, for 140 and 420 m3/h, respectively. The expected energy effect for a low thermal mass construction, e.g., a timber frame was much higher and the results obtained by using the numerical simulation were 116 MJ/a for 140 m3/h, and 273 MJ/a for 420 m3/h, respectively.
Life cycle assessment is an environmental method which estimates either a process or a building material within the cradle-to-grave cycle. Presently, it is one of a few tools that include all factors which may influence the environment. The authors used this tool to prove effects connected with potential efficient energy levels and a reduction in CO2 emissions within a building’s life cycle. For the purpose of our analyses, several types of single-family building were chosen and they were subjected to analysis in the fixed location of Warsaw. The research scope included a numerical analysis of the buildings concerning the level of embodied energies and the emission of greenhouse gases. The performed analysis proved that, within a 50-year cycle, the difference between the embodied energy from the best and worst building choices can amount to 14.87%, whereas a reduction in embodied carbon emissions can reach 20.65%. Each change in the building’s form and the type of building materials used, regardless of the usable area, influence the environmental impact. Therefore, this paper concludes that LCA, as a management tool, should be used cyclically as part of each phase of the design process. A multi-criteria method for selecting architectural solutions was proposed which considered minimum cumulative primary energy, minimum cumulative carbon emission and minimum cost of constructing a building.