Khaja Basheeruddin

Dr. Khaja Basheeruddin

Illinois Department of Public Health

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Michael GelbMichael Gelb
Michael Gelb
KBKhaja Basheeruddin
Khaja Basheeruddin
alberto burlinaalberto burlina
alberto burlina
HCHsiao-Jan Chen
Hsiao-Jan Chen
YCYin-Hsiu Chien
Yin-Hsiu Chien
DMDietrich Matern
Dietrich Matern
Tandem mass spectrometry (MS/MS) is the most universal platform currently available for the analysis of enzymatic activities and biomarkers in dried blood spots (DBS) for applications in newborn screening (NBS). Among the MS/MS applications in NBS, the most common is flow-injection analysis (FIA-) MS/MS, where the sample is introduced as a bolus injection into the mass spectrometer without the prior fractionation of analytes. Liquid chromatography combined with MS/MS (LC-MS/MS) has been employed for second-tier tests to reduce the false-positive rate associated with several nonspecific screening markers, beginning two decades ago. More recently, LC-MS/MS has been applied to primary screening for new conditions for which FIA-MS/MS or other methods, including genomic screening, are not yet adequate. In addition to providing a list of the currently used LC-MS/MS-based assays for NBS, the authors share their experience regarding the maintenance requirements of LC-MS/MS vs. FIA-MS/MS systems. The consensus is that the maintenance of LC-MS/MS and FIA-MS/MS instrumentation is similar, and LC-MS/MS has the advantage of allowing for a larger number of diseases to be screened for in a multiplex, cost-effective fashion with a high throughput and an adequate turnaround time.

Verified
Journal Article
Open access
PDF file
Barbara K. BurtonBarbara K. Burton
Barbara K. Burton
JCJoel Charrow
Joel Charrow
GHGeorge E. Hoganson
George E. Hoganson
JFJulie Fleischer
Julie Fleischer
DGDorothy Katherine Grange
Dorothy Katherine Grange
KBKhaja Basheeruddin
Khaja Basheeruddin
Statewide newborn screening for Pompe disease began in Illinois in 2015. As of 30 September 2019, a total of 684,290 infants had been screened and 395 infants (0.06%) were screen positive. A total of 29 cases of Pompe disease were identified (3 infantile, 26 late-onset). While many of the remainder were found to have normal alpha-glucosidase activity on the follow-up testing (234 of 395), other findings included 62 carriers, 39 infants with pseudodeficiency, and eight infants who could not be given a definitive diagnosis due to inconclusive follow-up testing.

Verified
Journal Article
Open access
PDF file
ZHZackary Michel Herbst
Zackary Michel Herbst
Leslie UrdanetaLeslie Urdaneta
Leslie Urdaneta
Terri L. KleinTerri L. Klein
Terri L. Klein
Barbara K. BurtonBarbara K. Burton
Barbara K. Burton
KBKhaja Basheeruddin
Khaja Basheeruddin
Michael GelbMichael Gelb
Michael Gelb
All newborn screening (NBS) for mucopolysaccharidosis-I and -II (MPS-I and MPS-II) is carried out via the measurement of α-iduronidase (IDUA) and iduronate-2-sulfatase (IDS) enzymatic activity, respectively, in dried blood spots (DBS). The majority of low enzyme results are due to pseudodeficiencies, and data from recent MPS-II population screenings and studies from the Mayo Clinic show that the false positive rate can be dramatically reduced by the inclusion of a second-tier analysis of glycosaminoglycans (GAGs) in DBS as part of NBS. In the present study, which focused on MPS-II, we obtained newborn DBS from 17 patients with severe MPS-II, 1 with attenuated MPS-II, and 6 patients with various IDS pseudodeficiencies. These samples were submitted to two different GAG mass spectrometry analyses in a comparative study: (1) internal disaccharide biomarkers and (2) endogenous biomarkers. For both of these methods, the biomarker levels in six patients with pseudodeficiencies were below the range measured in MPS-II patients. One patient with attenuated MPS-II was not distinguishable from severe disease patients, but all MPS-II patients were distinguishable from the reference range using both methods. The minimal differential factor (lowest GAG marker level in MPS-II samples divided by highest level in the reference range of 60 random newborns) was 3.01-fold for the internal disaccharide method. The endogenous biomarker method demonstrated an improved minimum differential of 5.41-fold. The minimum differential factors between MPS-II patients and patients with pseudodeficiencies for the internal disaccharide and endogenous biomarker methods were 3.77-fold and 2.06-fold, respectively. This study supports use of the second-tier GAG analysis of newborn DBS, especially the endogenous disaccharide method, as part of NBS to reduce the false positive rate.

Verified
Journal Article
Open access
PDF file
Barbara K. BurtonBarbara K. Burton
Barbara K. Burton
RHRachel Hickey
Rachel Hickey
LHLauren Hitchins
Lauren Hitchins
VSVera Shively
Vera Shively
JEJoan Ehrhardt
Joan Ehrhardt
KBKhaja Basheeruddin
Khaja Basheeruddin
X-linked adrenoleukodystrophy (X-ALD) is a genetic neurodegenerative disorder with an approximate incidence of 1 in 14,700 births. Both males and females are affected. Approximately one-third of affected males develop childhood cerebral adrenoleukodystrophy, which progresses rapidly to severe disability and death. In these cases, early surveillance and treatment can be lifesaving, but only if initiated before the onset of neurologic symptoms. Therefore, X-ALD was added to the Recommended Uniform Screening Panel. We report outcomes of the initial screening of approximately 276,000 newborns in Illinois. The lipid C26:0 lysophosphatidylcholine (C26:0-LPC) was measured in dried blood spots (DBS) using liquid chromatography with tandem mass spectrometry. Results ≥ 0.28 µmol/L were considered screen positive. Of 18 screen positive results detected, 12 cases were confirmed. Results were reported as borderline if initial and repeat analyses were ≥0.18 and <0.28 µmol/L. Of the 73 borderline screen results, 57 were normal after analysis of a second sample. Five X-ALD cases were identified from borderline screens. Newborn screening of X-ALD was successfully implemented in Illinois, and results were comparable to reports from other states. Early identification of infants with this potentially life-threatening disorder will significantly improve outcomes for these children.

Verified
Journal Article
Open access
PDF file
KBKhaja Basheeruddin
Khaja Basheeruddin
RSRong Shao
Rong Shao
FBFran Balster
Fran Balster
PGPearlie Gardley
Pearlie Gardley
LALaura Ashbaugh
Laura Ashbaugh
Population-based newborn screening for Krabbe disease was initiated by measurement of galactocerebrosidase (GALC) activity in the state of Illinois in December 2017. Due to the poor specificity of GALC for the diagnosis of Krabbe disease, second-tier testing services were provided to reduce the false positive rates for disease monitoring. Using ultra-pressure liquid chromatography coupled to mass spectrometry assay, a total of 497,147 newborns were screened. In total, 288 infants’ specimens (0.06%) having reduced GALC activity were sent out for second-tier testing to a reference laboratory. All newborns’ reduced GALC specimens were tested for psychosine levels, the presence of a 30-kb deletion and GALC sequencing. The results showed that two infants had elevated psychosine levels (10 and 35 nM) and were referred immediately for evaluation and treatment for Infantile Krabbe disease, and six infants had intermediate PSY levels (≥2 to 5 nM) and are under observation as suspected candidates for late-onset Krabbe disease. In addition, 178 infants had pseudodeficiency alleles, all having psychosine levels < 2.0 nM. Our data show that a high percentage of reduced GALC activity (62%) was due to the presence of pseudodeficiency alleles in the GALC gene. In conclusion, incorporation of psychosine measurements can identify infants with infantile Krabbe disease and probable late-onset Krabbe infants. Furthermore, Krabbe disease screening can be achieved at public health laboratories, and infants with infantile Krabbe disease can be diagnosed in timely manner for better outcome.

Verified
Journal Article
Open access
PDF file
DMDietrich Matern
Dietrich Matern
KBKhaja Basheeruddin
Khaja Basheeruddin
TKTracy Klug
Tracy Klug
GMGwendolyn McKee
Gwendolyn McKee
PEPatricia U. Edge
Patricia U. Edge
Joseph OrsiniJoseph Orsini
Joseph Orsini
Krabbe disease (KD) is part of newborn screening (NBS) in 11 states with at least one additional state preparing to screen. In July 2021, KD was re-nominated for addition to the federal Recommended Uniform Screening Panel (RUSP) in the USA with a two-tiered strategy based on psychosine (PSY) as the determinant if an NBS result is positive or negative after a first-tier test revealed decreased galactocerebrosidase activity. Nine states currently screening for KD include PSY analysis in their screening strategy. However, the nomination was rejected in February 2023 because of perceived concerns about a high false positive rate, potential harm to newborns with an uncertain prognosis, and inadequate data on presymptomatic treatment benefit or harm. To address the concern about false positive NBS results, a survey was conducted of the eight NBS programs that use PSY and have been screening for KD for at least 1 year. Seven of eight states responded. We found that: (1) the use of PSY is variable; (2) when modeling the data based on the recommended screening strategy for KD, and applying different cutoffs for PSY, each state could virtually eliminate false positive results without major impact on sensitivity; (3) the reason for the diverse strategies appears to be primarily the difficulty of state programs to adjust screening algorithms due to the concern of possibly missing even an adult-onset case following a change that focuses on infantile and early infantile KD. Contracts with outside vendors and the effort/cost of making changes to a program’s information systems can be additional obstacles. We recommend that programs review their historical NBS outcomes for KD with their advisory committees and make transparent decisions on whether to accept false positive results for such a devastating condition or to adjust their procedures to ensure an efficient, effective, and manageable NBS program for KD.