Ming Lei

Ming Lei

Auto-generated profile, based on publicly available information

Ming Lei


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2013 in Applied Optics
Verified
Journal Article
Closed access
PDF file
LFLishuang Feng
Lishuang Feng
MLMing Lei
Ming Lei
HLHuilan Liu
Huilan Liu
YZYinzhou Zhi
Yinzhou Zhi
JWJunjie Wang
Junjie Wang
A method to suppress backreflection noise due to facet reflection in a resonator integrated optic gyro (RIOG) is demonstrated using hybrid phase-modulation technology (HPMT). First, calculations are carried out to evaluate the effect of the backreflection. Although its amplitude has been remarkably decreased by angle polishing, residual backreflection noise is still a severe factor in RIOGs. Next, a hybrid phase-modulation method to eliminate the backreflection noise is constructed, and the frequency spectra of the photodetector outputs before and after adopting HPMT are analyzed. Theoretical analysis shows that the backreflection noise spectra will split from each other as a result of the hybrid phase modulation. In association with the pectinate-filter characteristics of digital correlation detection, the backreflection noise can be suppressed. Finally, the RIOG experimental setup is established and compared with opposite-slope triangle phase-modulation technology. HPMT has the advantage of suppressing backreflection noise, with the RIOG bias stability greatly improved from 2.34 to 0.22  deg/s (10 s integration time).

1 January 2022 in Chinese Optics Letters
Verified
Journal Article
Closed access
PDF file
KSKejun Shang
Kejun Shang
MLMing Lei
Ming Lei
HLHaowei Li
Haowei Li
TZTianqi Zhang
Tianqi Zhang
XYXiaozhi Yu
Xiaozhi Yu
LZLizhe Zhang
Lizhe Zhang
This study proposes a novel interferometric fiber optic gyroscope (IFOG) based on an integrated optical chip, application-specific integrated circuit, and small-diameter sensing coil. The overall size and weight of the prototype are 30 mm×30 mm×30 mm and 68 g, respectively, making it the smallest closed-loop IFOG, to the best of our knowledge. A static experiment shows that the bias stability of the integrated IFOG is very close to the theoretical accuracy limit determined by the fiber coil and can satisfy the requirements of near-navigation-grade compact inertial navigation systems.

1 January 2020 in Chinese Optics Letters
Verified
Journal Article
Closed access
KSKejun Shang
Kejun Shang
MLMing Lei
Ming Lei
QXQiang Xiang
Qiang Xiang
YNYonglin Na
Yonglin Na
LZLizhe Zhang
Lizhe Zhang
HYHuaiyong Yu
Huaiyong Yu
The CLP Publishing collects CLP journals and partnered optics and photonics journals, and provides readers an optical publishing platform with global influence. SPIE, OSA, CUP. Chinese Laser Press (CLP), established by Shanghai Institute of Optics and Fine Mechanics (SIOM), Chinese Academy of Sciences (CAS) and Chinese Optical Society (COS) in 2009, nowadays publishes eight journals and manages three online platforms.

10 January 2013 in Applied Optics
Verified
Journal Article
Closed access
PDF file
MLMing Lei
Ming Lei
LFLishuang Feng
Lishuang Feng
YZYinzhou Zhi
Yinzhou Zhi
HLHuilan Liu
Huilan Liu
JWJunjie Wang
Junjie Wang
NSNi Su
Ni Su
Resonator micro-optic gyro (RMOG) is a promising candidate for the next generation inertial rotation sensor based on the Sagnac effect. A current modulation technique used in an external cavity laser diode is proposed to construct the gyroscope system for the first time. The resonance curves before and after eliminating accompanying amplitude modulation are theoretically analyzed, calculated, and simulated; the demodulation curves with different modulation currents are formulated theoretically; and the optimum modulation current corresponding to the maximum sensitivity is obtained. The experiment results from the established RMOG experimental setup demonstrate that a bias stability of 2.7  deg/s (10 s integrated time) over 600 s, and dynamic range of ±500  deg/s are demonstrated in an RMOG with a silica optical waveguide ring resonator having a ring length of 12.8 cm.

26 June 2013 in Applied Optics
Verified
Journal Article
Closed access
PDF file
MLMing Lei
Ming Lei
LFLishuang Feng
Lishuang Feng
YZYinzhou Zhi
Yinzhou Zhi
HLHuilan Liu
Huilan Liu
The performance of the resonator integrated optic gyro (RIOG) is inevitably influenced by the intensity variation of the laser. In this work, the effect of intensity variation of the laser is mathematically formulized, analyzed, and experimentally validated, to our knowledge for the first time. First, the demodulated curves with different light intensities input of the integrated optical resonator (IOR) are simulated; the relationship between the slope of the demodulated curve near the resonant point and the light intensity input of the IOR is obtained. Second, the amplitudes of the output square waveforms with different zero biases are demonstrated, and it can be concluded that the effect of intensity variation has a high correlation with the nonzero bias between the clockwise and counterclockwise resonant frequency. Third, the experimental setup is constructed and the related measurements are performed, the test results are in good agreement with the analytical and numerical simulation, and in order to reach the limited ultimate sensitivity of the RIOG, it is necessary to restrict the nonreciprocal zero bias within 8.1  deg/s under an open-loop output scheme. Furthermore, to eliminate the noise induced by intensity variation of the laser and realize a high performance RIOG, a closed-loop operation is required.

11 October 2013 in Applied Optics
Verified
Journal Article
Closed access
PDF file
MLMing Lei
Ming Lei
LFLishuang Feng
Lishuang Feng
YZYinzhou Zhi
Yinzhou Zhi
In this paper, a novel method to improve the sensitivity of RIOGs is demonstrated by double-electrode phase modulation (DPM) technology. The scale factor of RIOGs with single-electrode phase modulation (SPM) and DPM are theoretically analyzed and calculated. The relationship between the slope rate in the linear region adjacent to the zero-offset point and the amplitudes of the triangle waveform with SPM and DPM are obtained; the RIOG's highest sensitivity appears when the triangle waveforms have amplitudes of 45.9 and 22.95 V, respectively. Compared with the SPM, the DPM shows great advantage in improving the RIOG scale factor, as well as its bias stability. Moreover, in measurements using the RIOG experimental setup, the scale factor is significantly increased from 1.49 to 2.76, which is coincident with the simulation result. The test results for long-term bias stability demonstrate that the DPM has the advantage of improving the signal-to-noise ratio (SNR); significantly, the RIOG long-term bias stability is greatly improved from 0.61 to 0.49 deg/s, which is the best long-term stability result reported to date, to the best of our knowledge, for a waveguide-type integrated optical resonator (IOR).