Antonio Cristaudo

Dr. Antonio Cristaudo

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2024 in Journal of Cleaner Production
Verified
Journal Article
Open access
Roberto BrunoRoberto Bruno
Roberto Bruno
VFVittorio Ferraro
Vittorio Ferraro
Antonio CristaudoAntonio Cristaudo
Antonio Cristaudo
Piero BevilacquaPiero Bevilacqua
Piero Bevilacqua

22 November 2024 in ACTA IMEKO
Verified
Journal Article
Open access
PDF file
Antonio CristaudoAntonio Cristaudo
Antonio Cristaudo
VFVittorio Ferraro
Vittorio Ferraro
Francesco NicolettiFrancesco Nicoletti
Francesco Nicoletti
GPGiulia Palermo
Giulia Palermo
Dimitrios KaliakatsosDimitrios Kaliakatsos
Dimitrios Kaliakatsos
In the residential building sector, a sustainable human-environment relationship can be achieved by encouraging both the use of renewable sources and the enhancement of energy efficiency in technical systems and building envelopes. This article performs an energy analysis to evaluate the reduction in energy demand attained by installing two Trombe walls on the south-facing wall of the variable orientation test station at the University of Calabria. The two passive systems were symmetrically placed on either side of the existing window system. The assessment of monthly energy demand during the heating season was conducted using the dynamic simulation software DesignBuilder®. To determine the optimal configuration of the Trombe walls, the influence on energy demand related to the materials used for the support structure, the type and number of glasses forming the solar space, the size of the solar space, and the dimensions of the vents were evaluated. The findings indicate that the installation of the two Trombe walls, each comprising two vents with an area of 0.1 m² and a solar space depth of 0.20 m, vertically enclosed by three glass walls with double low-emissivity glazing, results in a 60.62 % reduction in winter energy demand.

17 March 2026 in Sustainable Energy Technologies and Assessments
Verified
Journal Article
Open access
Antonio CristaudoAntonio Cristaudo
Antonio Cristaudo
Francesco NicolettiFrancesco Nicoletti
Francesco Nicoletti
Francesco RovenseFrancesco Rovense
Francesco Rovense
Walter GaggioliWalter Gaggioli
Walter Gaggioli
VFVittorio Ferraro
Vittorio Ferraro
Natale ArcuriNatale Arcuri
Natale Arcuri

19 January 2026 in Buildings
Verified
Journal Article
Open access
PDF file
Antonio CristaudoAntonio Cristaudo
Antonio Cristaudo
Francesco NicolettiFrancesco Nicoletti
Francesco Nicoletti
Cristina CarpinoCristina Carpino
Cristina Carpino
Roberto BrunoRoberto Bruno
Roberto Bruno
This paper introduces the dynamic hygrothermal performances of existing walls in humid climates using the EN ISO 15026 procedure. Water content, mould formation and freezing risk were investigated considering rock wool (RW) and expanded polystyrene (EPS) allocated at different points of two typologies of existing walls requiring renovation. Results show that RW is recommended for insulation on the external side, whereas EPS is more suitable for the internal side. A freezing risk occurs in massive walls insulated internally with RW in severe winter climates. Mould formation appears in the initial phases on the renovated side, driven by the built-in humidity of the new layers. Wall thermal transmittance shows large fluctuations, especially in lightweight structures renovated with EPS, reaching an increase of over 22% at the beginning of the heating period, driven by EPS water content peaks of 1.9 kg/m2 in cold climates when installed on the external side, achieved in a stabilized regime and independently from the wall’s technical solution. Outcomes confirm transient hygrothermal analysis as the recommended approach to evaluate the component behaviour over a long-term projection, facilitating sizing in the design phase and ensuring compliance with regulations for retrofitted elements.

31 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
Roberto BrunoRoberto Bruno
Roberto Bruno
Antonio CristaudoAntonio Cristaudo
Antonio Cristaudo
In the near future, the building sector will continue to absorb the greatest share of primary energy worldwide. It is necessary to find innovative solutions that promote energy efficiency through renovation measures, especially in historical buildings, for which refurbishment is constrained by several issues. In this study, we propose a novel Trombe Wall configuration that is easily integrable and based on a rock wall made of caged stone to use as a thermal accumulator. The system was investigated preliminarily using a transient Finite Difference Method (FDM) code to analyse the temperature field inside the rock wall. Successively, FDM results were employed as input data in TRNSYS simulations to determine the savings achievable in thermal heating requirements. The results demonstrated that the proposed solution, in the considered climate and on a reference historic building, can produce monthly heating savings varying between 26% and 85%. So, the rock wall results in a reliable solution for buildings in which refurbishment is difficult, allowing for preserving aesthetic features and improving energy efficiency by rationally using solar radiation.

11 December 2025 in Energy
Verified
Journal Article
Closed access
PCPaolo Cutuli
Paolo Cutuli
Antonio CristaudoAntonio Cristaudo
Antonio Cristaudo
Piero BevilacquaPiero Bevilacqua
Piero Bevilacqua
VFVittorio Ferraro
Vittorio Ferraro
JSJessica Settino
Jessica Settino
PMPietropaolo Morrone
Pietropaolo Morrone