The main consequence of radiation damage on a Silicon-Photomultiplier (SiPM) is a significant increase in the dark current. If the SiPM is not adequately cooled, the power dissipation causes it to heat up, which in turn affects its performance based on the temperature. In order to investigate this heating effect, experiments were carried out using a KETEK SiPM glued on an Al2O3 substrate, as well as HPK SiPMs that were either glued onto an Al2O3 substrate or a flexible PCB. The assemblies were connected either directly to a temperature-controlled chuck on a probe station or through layers of materials with well-defined thermal resistance. A DC-mode LED was used to illuminate the SiPM, and the resulting SiPM current was measured to determine the steady-state temperature. This temperature depended on the power dissipated in the multiplication region of the SiPM and the thermal resistance. This information can be utilized to adjust the SiPMs working point, taking into account the effects of self-heating. Similarly, this approach can be applied to packaged SiPMs that have an unknown thermal contact to a heat sink.
The main effect of radiation damage in a Silicon-Photolumtiplier (SiPM) is a dramatic increase in the dark current. The power dissipated, if not properly cooled, heats the SiPM, whose performance parameters depend on temperature. Heating studies were performed with a KETEK SiPM, glued on an Al$_2$O$_3$ substrate, which is either directly connected to the temperature-controlled chuck of a probe station, or through layers of material with well-known thermal resistance. The SiPM is illuminated by a LED operated in DC-mode. The SiPM current is measured and used to determine the steady-state temperature as a function of power dissipated in the multiplication region of the SiPM and thermal resistance, as well as the time dependencies for heating and cooling. This information can be used to correct the parameters determined for radiation-damaged SiPM for the effects of self-heating. The method can also be employed for packaged SiPMs with unknown thermal contact to a heat sink. The results presented in this paper are preliminary.