Scientific data on the long-term clinical performance of cantilever zirconia resin-bonded fixed dental prostheses (RBFDPs) replacing missing incisors are lacking. The purpose of this clinical study was to evaluate the survival, retention, and success rates of cantilever zirconia ceramic RBFDPs replacing missing maxillary and mandibular incisors. A total of 258 patients had been provided with 328 cantilever zirconia RBFDPs to replace missing incisors in the period 2001 to 2022. Tooth preparation was minimal, limited to the enamel, and consisted of a veneer design. All restorations had been adhesively bonded, and the patients were periodically followed up. The Kaplan-Meier test was applied to assess survival, retention, and success rates. The Log-Rank test was used to compare the aforementioned rates among 3 groups (Group C: maxillary central incisor RBFDPs; Group L: maxillary lateral incisor RBFDPs; and Group M: mandibular central and lateral RBFDPs). Seventeen patients could not be evaluated because of loss of contact (dropout rate 6.6%). A total of 310 cantilever zirconia RBFDPs inserted in 241 patients were followed for a mean period of 85 ±55 months. A 15-year survival rate of 97.3% (confidence interval [CI]: 95.7%-98.9%) was calculated using the Kaplan-Meier method. Over the observation time, 17 RBFDPs debonded, resulting in a retention rate of 82.3% (CI: 77.2%-87.4%), of which 16 were adhesively rebonded with no further complications. Pontic location did not statistically affect the survival or retention rates (P>.05) but did significantly affect the success rate (P=.021). Zirconia ceramic cantilever RBFDPs provided a minimally invasive treatment option for replacing missing maxillary and mandibular incisors with excellent clinical outcomes.
This study was conducted to evaluate the accuracy of 3D-printed surgical guides before and after sterilization in a steam sterilizer. A test-model incorporating three implant replicas was customized. A total of forty guides were printed from five printable resins. A group made from a self-curing composite served as control group. The guides were checked for fit. Vertical discrepancies between the model and guides were measured at standardized points at a load of 500 g (P1). The guides were connected to implant replicas and scanned, and their angles were digitally measured. The specimens were sterilized in a steam sterilizer at 121 °C for 20 min at 2 bar pressure. Vertical discrepancies (P2) and angulations were remeasured. Additionally, the specimens were repositioned with an increased load, and measurements were repeated (P3). All specimens were repositionable after sterilization. The smallest variation in discrepancy at a 500 g load was 428 µm, whereas the greatest was 1487 µm. Under an increased force, the smallest change was 94 µm, while the greatest was 260 µm. The level of significance α = 0.05 (95% confidence interval) was set for all tests. The variation in the measured angles was not statistically significant (Kruskal–Wallis’s test, p > 0.05). The accuracy was affected by the material and sterilization, but it was clinically acceptable when an increased load was applied during repositioning.
About Me
Dr. Med Dent Habil Christine Yazigi.
DDS, MSc, Dr. med. dent. Habil
Dr. Med Dent Habil Christine Yazigi.
DDS, MSc, Dr. med. dent. Habil