Muhammed Hashid

Dr. Muhammed Hashid

Civil Engineering Department, Maulana Azad National Institute of Technology, Bhopal, India

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2020 in Journal of Hydraulic Research
Verified
Journal Article
Closed access
Muhammed HashidMuhammed Hashid
Muhammed Hashid
AHAjmal Hussain
Ajmal Hussain
ZAZulfequar Ahmad
Zulfequar Ahmad
Formation of an air-entraining vortex in the vicinity of an intake structure is considered to be a major problem of the intake. These vortices are not acceptable as they decrease the efficiency of the intake structures. Adequate submergence above the intake can effectively halt the formation of such vortices. The present study deals with the analytical and experimental works carried out on a horizontal side circular intake with and without bellmouth transitions in an open channel flow. The parameters affecting the critical submergence of intakes have been identified and relevant parameters have been used to develop relationships for the critical submergence of the side circular intakes. The accuracy of the proposed relationships is well within the acceptable limit. The results of the present study can be utilized by field engineers and practitioners for the rational design of side intakes used for diverting flow without the formation of air-entraining vortices.

1 December 2015 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
Muhammed HashidMuhammed Hashid
Muhammed Hashid
AHA. Hussain
A. Hussain
ZAZ. Ahmad
Z. Ahmad

1 October 2022 in Journal of Hydraulic Engineering
Verified
Journal Article
Closed access
PDF file
Muhammed HashidMuhammed Hashid
Muhammed Hashid
ZAZulfequar Ahmad
Zulfequar Ahmad
The present paper discusses an experimental study on the critical submergence for lateral dual horizontal intakes that are placed in a row and perpendicular to a uniform approach flow. The effect of clear spacing between the dual square intakes extracting the same flow discharge on the critical submergence is critically studied and found that the dual intakes show mutual influence on the flow withdrawal and critical submergence, which decreases with an increase in the clear spacing. The intakes behaved as isolated intakes in the same flow condition with separate vortices causing multiple vortices at a limiting clear spacing of twice the intake size. The downstream intake of the dual intakes is first affected by the air entrainment from surface vortex formation when both intakes operated under the same discharge condition for spacing less than twice the intake size. The effects of other significant parameters like sill height and intake size under various approach flow and intake flow conditions on the vortex formations at critical submergence of dual intakes are also studied. The intake flow Reynolds number and Weber number significantly affect the critical submergence of the lateral dual intakes, indicating the relevance of viscosity and surface tension effects on surface vortex formations. An empirical relationship for the prediction of critical submergence for dual side intakes has been developed and found to be in good agreement with the observed data with an error of less than ±15% . The developed equation is also applicable for the computation of critical submergence for single-side horizontal square intakes under uniform approach flow. The outcomes of the study shall be helpful for the field engineers in fixing the invert level of the single and dual intake for avoiding the air-entraining vortex.

4 July 2023 in Journal of Hydraulic Research
Verified
Journal Article
Closed access
Muhammed HashidMuhammed Hashid
Muhammed Hashid
TET. I. Eldho
T. I. Eldho

1 September 2023 in Canadian Journal of Civil Engineering
Verified
Journal Article
Closed access
Muhammed HashidMuhammed Hashid
Muhammed Hashid
AHAjmal Hussain
Ajmal Hussain
ZAZulfequar Ahmad
Zulfequar Ahmad
This paper discusses a numerical model study for the simulation of flow characteristics and critical submergence for a laterally placed horizontal circular bottom intake under uniform flow. The proposed model simulates the free surface using the volume of fluid model to check the vortex formation at critical submergence. A new combined approach using phase volume fraction and swirl strength-based vortex identification mechanism is used to compute the critical submergence. The swirl strength-based vortex identification mechanism can show the vortex tube in approach flow with swirl generated at the free surface due to the axial flow withdrawal through side bottom intake at critical submergence. The computational fluid dynamics (CFD) model results were validated using experimental data, which showed a maximum error of less than ±10% in the prediction of the critical submergence. The effect of significant parameters like intake and approach flow Froude number and sill height of intake on the critical submergence is discussed. The results of this study help practitioners to adopt CFD-based numerical modelling for the design of water intakes instead of entirely relying on physical model studies, which require more finance and time.

16 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
VPVaibhav Peter
Vaibhav Peter
Muhammed HashidMuhammed Hashid
Muhammed Hashid
HKHarsangeet Kaur
Harsangeet Kaur
The present study delivers a quantitative evaluation of the impact of urban expansion on regional atmospheric composition across a highly urbanizing Central Indian territory, over a seven-year trajectory (2019-2025). Sentinel-5P satellite data provided the yearly average column densities of key pollutants. The urbanized land percentage increased by 4.18% which represents a total growth of about 34.6%, and the population grew by about 6.68%, which went up to 86.25 million in year 2025. The tracking of greenhouse gas (Methane) levels indicated a rise of about 3.17%, while Ozone showed an increasing trend with an approximate growth of 5.40%, Nitrogen dioxide exhibited fluctuations, varying by around 12.68% overall. Similarly, Formaldehyde and UV Aerosol Index also showed variability and increased significantly over the period, with the latter indicating notable changes in aerosol loading. To assess spatial scale sensitivity, comparative MGWR modelling was applied, yielding a mean R2 value of 0.820 across the central Indian territory(0.25º), and at the district level it varied between 0.874 (0.25º) and 0.668 (0.1º), complemented by statistical correlation analyzes assessing both linear and monotonic relationships. Also, formaldehyde and nitrogen dioxide column density ratio was further analyzed as an indicator of the relative abundance of volatile organic compound and nitrogen oxides. The study offers a scalable framework for air quality management by establishing a link between urban surface anthropogenic metrics and satellite-observed pollutants level, in a region with sparse monitoring systems. Further, this study also indicates the need of incorporating spatially varying parametric relationships to urban planning and atmospheric policy to mitigate the effects of anthropogenic forcing on regional atmospheric composition in rapidly growing south Asian regions.