Omar yaseen Saeed

Mr. Omar yaseen Saeed

Institute for Energy Engineering, Universitat Politècnica de València, Valencia, Spain
+1
orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2026 in IEEE Access
Verified
Journal Article
Open access
Omar yaseen SaeedOmar yaseen Saeed
Omar yaseen Saeed
Carlos Roldán-BlayCarlos Roldán-Blay
Carlos Roldán-Blay
CRCarlos Roldán-Porta
Carlos Roldán-Porta
Interconnected microgrids (IMGs) offer opportunities to aggregate distributed energy resources (DERs) for loss reduction and voltage improvement, yet planning under daily variability remains challenging. This study presents a physics-aware planning and validation framework for five interconnected IEEE-33 microgrids integrating photovoltaic (PV), battery energy storage (BESS), one microgrid-specific Distributed Energy Resources (wind, hydro, biogas, or diesel), Electric Vehicle charging demand, and shunt capacitors (CAP). Snapshot optimization was performed using the Geese V-Formation Algorithm with a loss-focused objective, adequacy, and undervoltage penalties. The optimized configuration was validated over 24 hours using an AC backward–forward sweep under dynamic loads, weather-based Distributed Energy Resources generation, and Battery Energy Storage Systems state-of-charge constraints. The final GVFA planning simulation, implemented in Python, demonstrated feeder loss reductions of 50–70% and minimum voltage improvements between 0.956 and 0.966 p.u., with higher values during hourly operation. Three microgrids consistently acted as net-exporters (island-capable), while two remained net-importers, leveraging tie-line diversity. Methodologically, Geese V-Formation Algorithm’s leader–follower dynamics, neighbor-local coupling, and stochastic rounding efficiently traversed a mixed-integer, nonconvex search space. Systemically, the collaborative interconnected approach delivered system-wide benefits beyond localized optimization. The framework provides actionable recommendations for Distributed Energy Resources siting and sizing to enhance loss reduction, voltage stability, and operational flexibility under realistic intermittent conditions.
1

11 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Omar yaseen SaeedOmar yaseen Saeed
Omar yaseen Saeed
Carlos Roldán-BlayCarlos Roldán-Blay
Carlos Roldán-Blay
CRCarlos Roldán-Porta
Carlos Roldán-Porta
High penetration of distributed energy resources (DERs) is reshaping radial distribution networks, yet weather-dependent generation, variable demand, and feeder-level surplus–deficit imbalance can compromise voltage quality and coordinated operation. Existing planning approaches often optimize feeders independently and therefore provide limited insight into how local DER portfolios should support inter-feeder energy exchange under time-varying conditions. This study proposes a weather-driven two-stage Geese V-Formation Algorithm (GVFA) framework for planning DER integration and feeder coordination in a practical five-feeder 11 kV Tajeeyaat/North Baghdad system, with complementary validation on a five-instance IEEE 33-bus benchmark cluster. Stage 1 optimizes the siting and sizing of photovoltaic units, wind turbines, battery energy storage systems, capacitor banks, and feeder-specific auxiliary resources using backward/forward-sweep load flow. Stage 2 uses hourly surplus–deficit profiles to select tie-switch configurations and exchange capacities for feeder-to-feeder energy sharing. The framework is evaluated through convergence analysis, optimizer comparison, N-1 contingencies, and seasonal load-growth tests. For the practical system, 24 h aggregate losses decreased from 11,258.1571 to 3367.8481 kWh-eq, corresponding to a 70.0853% reduction. The minimum-voltage range improved from 0.9497–0.9898 to 0.9897–0.9997 p.u., while grid-import reduction reached 94.0270%. For the IEEE-33 cluster, 24 h aggregate losses decreased from 31,746.4712 to 6381.1403 kWh-eq, corresponding to a 79.8997% reduction. The minimum-voltage range improved from 0.8268–0.8632 to 0.9465–0.9683 p.u., while grid-import reduction reached 84.4596%. The framework provides a planning-oriented, sensor-ready decision-support basis for DER siting, voltage-support assessment, grid-import reduction, and candidate inter-feeder exchange corridors.
1

8 June 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Omar yaseen SaeedOmar yaseen Saeed
Omar yaseen Saeed
Carlos Roldán-BlayCarlos Roldán-Blay
Carlos Roldán-Blay
CRCarlos Roldán-Porta
Carlos Roldán-Porta
This research introduces a unique optimization framework centered on the Geese V-Formation Algorithm to enhance the technical planning of distributed energy resources in renewable microgrid-oriented radial distribution systems. The proposed methodology addresses the optimal placement and sizing of photovoltaic panels, wind turbines, battery energy storage systems, and capacitor banks to provide comprehensive voltage support, minimize active power losses, and refine overall grid functionality. Drawing inspiration from the aerodynamic efficiency of migratory geese, the Geese V-Formation Algorithm integrates dynamic leader-follower coordination, adaptive role rotation, and cooperative information exchange mechanisms. These features allow the algorithm to effectively balance global exploration and local exploitation, making it uniquely suited to address the complex, nonlinear, and multi-objective nature of modern microgrid design. The effectiveness of this approach was evaluated through rigorous simulations on the IEEE-33 and IEEE-69 bus distribution systems utilizing the Python programming language. The empirical results indicate that the Geese V-Formation Algorithm achieves substantial power loss reductions, reaching 91.62% and 92.45%, respectively, when integrating solar and wind resources with energy storage and reactive power compensation. Furthermore, the optimized configurations significantly improved bus voltage profiles and enhanced substation power factors, confirming the technical effectiveness of the framework under the considered benchmark constraints. By providing a technical decision-support approach for engineers and utility planners, this framework facilitates the deployment of reliable, decentralized renewable energy systems that align with global energy transition objectives and promote sustainable infrastructure development.
1