Yoonho Roh

Prof. Dr. Yoonho Roh


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2021 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
Yoon Ho RohYoon Ho Roh
Yoon Ho Roh
Cheongwoon ChoCheongwoon Cho
Cheongwoon Cho
CRChang Hun Ryu
Chang Hun Ryu
JLJe Hun Lee
Je Hun Lee
SJSeong Mok Jeong
Seong Mok Jeong
HLHaebeom Lee
Haebeom Lee
Corrective osteotomy has been applied to realign and stabilize the bones of dogs with lameness. However, corrective osteotomy for angular deformities requires substantial surgical experience for planning and performing accurate osteotomy. Three-dimensional printed patient-specific guides (3D-PSGs) were developed to overcome perioperative difficulties. In addition, novices can easily use these guides for performing accurate corrective osteotomy. We compared the postoperative results of corrective osteotomy accuracy when using 3D-PSGs in dogs between novice and experienced surgeons. We included eight dogs who underwent corrective osteotomy: three angular deformities of the radius and ulna, three distal femoral osteotomies, one center of rotational angle-based leveling osteotomy, and one corrective osteotomy with stifle arthrodesis. All processes, including 3D bone modeling, production of PSGs, and rehearsal surgery were carried out with computer-aided design software and a 3D-printed bone model. Pre- and postoperative positions following 3D reconstruction were evaluated by radiographs using the 2D/3D registration technique. All patients showed clinical improvement with satisfactory alignment and position. Postoperative accuracy evaluation revealed no significant difference between novice and experienced surgeons. PSGs are thought to be useful for novice surgeons to accurately perform corrective osteotomy in dogs without complications.

1 January 2018 in Journal of Veterinary Science
Verified
Journal Article
Open access
PDF file
JPJi Yong Park
Ji Yong Park
BJBum Soo Jeong
Bum Soo Jeong
Yoon Ho RohYoon Ho Roh
Yoon Ho Roh
SJSeong Mok Jeong
Seong Mok Jeong
HLHaebeom Lee
Haebeom Lee
Park JY, et al. J Vet Sci. 2018 Sep;19(5):693-698. https://doi.org/10.4142/jvs.2018.19.5.693

30 June 2024 in Animals
Verified
Journal Article
Open access
PDF file
EJEunbin Jeong
Eunbin Jeong
YJYoungJin Jeon
YoungJin Jeon
TKTaewan Kim
Taewan Kim
DLDongbin Lee
Dongbin Lee
Yoon Ho RohYoon Ho Roh
Yoon Ho Roh
In small-breed dogs with concurrent cranial cruciate ligament rupture (CCLR) and medial patellar luxation (MPL), correcting both disorders is are essential for restoring normal gait. However, the previously described surgical treatment, using two osteotomy technique, poses a high risk of fracture and instability. Addressing CCLR and MPL with a single osteotomy and implant was considered superior to the conventional method. Therefore, a pre-contoured modified tibial plateau leveling osteotomy (PCM–TPLO) plate facilitating medial shifting of the proximal tibia was developed. We compared postoperative alignment and strength between this novel plate group and a conventional tibial plateau leveling osteotomy (TPLO) plate group using eight small-breed dog cadavers each. Additionally, we investigated the potential of the novel plate as an alternative to tibial tuberosity transposition. Postoperative alignment and strength were assessed through radiographs and mechanical testing. Measurements including tibial plateau angle, mechanical medial proximal tibial angle, and number of screws within the joint were also analyzed. There were no significant differences in all measured parameters. For the novel plate, the medial displacement ratio of the proximal tibia was confirmed to be approximately 30%, and the result was thought to be appropriate. These findings suggest that the PCM–TPLO plate could be a promising alternative for treating concurrent CCLR and MPL in small-breed dogs.

1 May 2022 in American Journal of Veterinary Research
Verified
Journal Article
Open access
PDF file
Yoon Ho RohYoon Ho Roh
Yoon Ho Roh
DKDae-Hyun Kim
Dae-Hyun Kim
SJSeong Mok Jeong
Seong Mok Jeong
HLHaebeom Lee
Haebeom Lee
OBJECTIVE: To assess the accuracy of transsphenoidal hypophysectomy using 3-D printed patient-specific guides (3D-PSGs) in small-breed dogs. ANIMALS: Heads obtained from the cadavers of 19 small-breed dogs (ex vivo portion of study) and 3 healthy adult (3 to 4 years) purpose-bred Beagles with a median body weight of 9.2 kg. PROCEDURES: In the ex vivo study, CT images of the cadavers were collected. The position, width, and length of the pituitary fossa and the pilot hole (insertion angle and place) were measured. Using PSGs, 19 pilot holes were made for the pituitary gland fossa, and CT was performed to assess the position accuracy. In the in vivo study, 3 surgical windows from the pilot holes were made using PSGs. Repeated CT and MRI were performed to evaluate the safeness and effectiveness of PSGs, followed by necropsy. RESULTS: In the ex vivo study, the median (interquartile range) difference between the pre- and postoperative insertion angles was 2° (0° to 3.5°) and the median deviation of the pilot hole was 0.46 mm (0 to 1.58 mm). In the in vivo study, the surrounding structures were not damaged, and favorable outcomes were evident in terms of the shape, size, and position of the surgical window. CLINICAL RELEVANCE: 3D-PSGs provided a safe and effective surgical window for transsphenoidal hypophysectomy. Our findings emphasized the applicability of PSGs in brain surgery, in terms of accuracy and effectiveness.

29 November 2023 in Animals
Verified
Journal Article
Open access
PDF file
CLChae-Yeong Lee
Chae-Yeong Lee
SLSung-Lim Lee
Sung-Lim Lee
EKEunJu Kim
EunJu Kim
JKJinsu Kang
Jinsu Kang
SJSunjun Jung
Sunjun Jung
DLDongbin Lee
Dongbin Lee
Whole blood viscosity, a hemorheological factor, is currently used for diagnosis, as it is correlated with various vascular diseases that are difficult to diagnose early with a general blood test. It was determined that it was necessary to set reference intervals for further studies and utilization of whole blood viscosity in cats, a representative companion animal, and this study was conducted. Fifty healthy cats were recruited for the study, and whole blood viscosity, complete blood count, and serum chemistry tests were performed. The reference intervals of whole blood viscosity were 15.169 to 43.684 cP at a shear rate of 1 s−1 reflecting diastole, and 3.524 to 5.544 cP at a shear rate of 300 s−1 reflecting systole. Red blood cells, hematocrit, hemoglobin, white blood cells, and neutrophils in the complete blood count, and total protein, albumin, globulin, and cholesterol in the serum chemistry were significantly correlated with whole blood viscosity. The results of this study set the reference intervals of whole blood viscosity for healthy cats in a wide shear rate range that has not yet been fully established, and its correlation with other blood indicators investigated.

31 December 2022 in Journal of Veterinary Clinics
Verified
Journal Article
Open access
PDF file
HSHwa-Joeng Shin
Hwa-Joeng Shin
HLHaebeom Lee
Haebeom Lee
Yoon Ho RohYoon Ho Roh
Yoon Ho Roh
Hwa-Joeng Shin, Hae-Beom Lee, Yoon-Ho Roh. J Vet Clin 2022;39:294-301. https://doi.org/10.17555/jvc.2022.39.6.294