Zhao-Chi Chen

Prof. Zhao-Chi Chen

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2025 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Zhao-Chi ChenZhao-Chi Chen
Zhao-Chi Chen
CLCheng-Che Liu
Cheng-Che Liu
Minh-Quang TranMinh-Quang Tran
Minh-Quang Tran
Point-of-care (POC) diagnostic technologies have become essential for the real-time monitoring and management of chronic wounds, where maintaining a moist environment and controlling pH levels are critical for effective healing. In this study, a flexible pH sensor based on a graphene/molybdenum disulfide (graphene/MoS2) composite interdigitated electrode (IDE) structure was fabricated using pulsed laser ablation. The pH sensor, with an active area of 30 mm × 30 mm, exhibited good adhesion to the polyethylene terephthalate (PET) substrate and maintained structural integrity under repeated bending cycles. Precise ablation was achieved under optimized conditions of 4.35 J/cm2 laser fluence, a repetition rate of 300 kHz, and a scanning speed of 500 mm/s, enabling the formation of defect-free IDE arrays without substrate damage. The influence of laser processing parameters on the surface morphology, electrical conductivity, and wettability of the composite thin films was systematically characterized. The fabricated pH sensor exhibited high sensitivity (~4.7% change in current per pH unit) across the pH 2–10 range, rapid response within ~5.2 s, and excellent mechanical stability under 100 bending cycles with negligible performance degradation. Moreover, the sensor retained > 95% of its stable sensitivity after 7 days of ambient storage. Furthermore, the pH response behavior was evaluated for electrode structures with different pitches, demonstrating that structural design parameters critically impact sensing performance. These results offer valuable insights into the scalable fabrication of flexible, wearable pH sensors, with promising applications in wound monitoring and personalized healthcare systems.

30 January 2026 in The Analyst
Verified
Journal Article
Closed access
PDF file
NHNguyen Dinh Hien
Nguyen Dinh Hien
ASAsaduzzaman
Asaduzzaman
ADAjitesh Dhal
Ajitesh Dhal
BZBashir Danmahawayi Zubairu
Bashir Danmahawayi Zubairu
CCChang-I Chen
Chang-I Chen
TYTzu-Sen Yang
Tzu-Sen Yang
Raman tweezers and explainable machine learning enable label-free single-cell profiling of endometriosis, revealing unique biochemical signatures for accurate diagnosis.

12 February 2024 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
QWQi-Xuan Wu
Qi-Xuan Wu
TCTien-Li Chang
Tien-Li Chang
Zhao-Chi ChenZhao-Chi Chen
Zhao-Chi Chen
WHWen-Tse Hsiao
Wen-Tse Hsiao
SHSong-Pu Huang
Song-Pu Huang

21 January 2026 in Ceramics International
Verified
Journal Article
Closed access
Zhao-Chi ChenZhao-Chi Chen
Zhao-Chi Chen
TCTien-Li Chang
Tien-Li Chang
STShih-Feng Tseng
Shih-Feng Tseng
MTMinh-Quang Tran
Minh-Quang Tran

9 July 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
Zhao-Chi ChenZhao-Chi Chen
Zhao-Chi Chen
Minh-Quang TranMinh-Quang Tran
Minh-Quang Tran
A capillary-driven microfluidic electrical screening platform was developed using silver nanoparticle (AgNP)-decorated laser-patterned villous microstructures on a glass substrate for the analysis of H3N2-infected A549 cells. The device integrated nanosecond laser patterning, AgNP conductive thin-film formation, passive capillary transport, and direct electrical readout within a single microfluidic sensing structure. Villous-like arrays were fabricated using a 1064 nm IR pulsed laser at a fluence of 4.35 J/cm2, with a repetition rate of 300 kHz, pulse overlap of 96.7% and scanning speed of 500 mm/s. The fabricated structures exhibited a diameter of 60 μm, height of 80 μm and interpillar pitches ranging from 30 to 90 μm. After AgNP deposition, the surface showed a dominant Ag content of 59.2%, confirming successful formation of conductive microstructured electrodes. The 30 μm pitch structure produced the highest current response of 22 μA at 1 V and the highest ΔInorm of 0.053 after introduction of H3N2-infected A549 samples. Wettability and capillary transport were tunable by pitch, with contact angles (CAs) decreasing from 140° to 30° and flow velocities decreasing from 0.1 mm/s to 0.03 mm/s. Formalin-fixed H3N2-infected A549 cells were electrically distinguished from non-infected A549 controls over 101–106 PFU/μL, with detectable responses down to 101 PFU/μL. These results demonstrate a label-free, self-driven, and fabrication-oriented microfluidic strategy for electrical screening of virus-associated cellular samples.