Louise S. Owen

Louise S. Owen

Auto-generated profile, based on publicly available information

Louise S. Owen

Newborn Services and Newborn Research, Royal Women’s Hospital, Melbourne, Australia

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2016 in New England Journal of Medicine
Verified
Journal Article
Closed access
PDF file
CRCalum T Roberts
Calum T Roberts
LOLouise S Owen
Louise S Owen
BMBrett J Manley
Brett J Manley
DFDag H Frøisland
Dag H Frøisland
SDSusan M Donath
Susan M Donath
HIHIPSTER Trial Investigators
HIPSTER Trial Investigators
Treatment with nasal high-flow therapy has efficacy similar to that of nasal continuous positive airway pressure (CPAP) when used as postextubation support in neonates. The efficacy of high-flow therapy as the primary means of respiratory support for preterm infants with respiratory distress has not been proved.

1 April 2017 in The Lancet
Verified
Journal Article
Closed access
LOLouise S Owen
Louise S Owen
BMBrett J Manley
Brett J Manley
PDPeter G Davis
Peter G Davis
LDLex W Doyle
Lex W Doyle

20 February 2011 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Verified
Journal Article
Closed access
PDF file
LOL S Owen
L S Owen
CMC J Morley
C J Morley
Jennifer DawsonJennifer Dawson
Jennifer Dawson
PDP G Davis
P G Davis
Background: Nasal intermittent positive pressure ventilation (NIPPV) may be beneficial but the mechanisms of action are undetermined. Aim: To investigate the effects of non-synchronised NIPPV on spontaneous breathing in premature infants. Methods: 10 infants receiving ventilator generated non-synchronised NIPPV were studied for 30 min. Delivered pressure was measured at the nose; respiration was recorded using respiratory inductance plethysmography. Oxygen saturation, carbon dioxide, heart rate, inspired oxygen and video images were recorded. Results: Median gestational age, birth weight, age and study weight were 25+3 weeks, 797 g, 24 days and 1076 g. When the NIPPV pressure peak commenced during spontaneous inspiration the inspiratory time increased by 21% (p=0.002), relative tidal volume increased by 15% (p=0.01) and expiratory time was unchanged. When the NIPPV pressure peak commenced during spontaneous expiration the expiratory time increased by 13% (p=0.04). NIPPV pressures delivered during apnoea (range 8–28 cm H2O) produced chest inflation 5% of the time, resulting in small tidal volumes (26.7% of spontaneous breath size) but reduced oxygen desaturation. NIPPV pressure peaks occurred throughout spontaneous respiration proportional to the inspiratory: expiratory ratio. Conclusion: NIPPV pressure peaks only resulted in a small increase in relative tidal volumes when delivered during spontaneous inspiration. During apnoea pressure peaks occasionally resulted in chest inflation, which ameliorated oxygen desaturations. Infants did not become entrained with the NIPPV pressure changes. Synchronising every rise in applied pressure with spontaneous inspiration may increase the effectiveness of NIPPV and warrants investigation.

1 June 2016 in Seminars in Fetal and Neonatal Medicine
Verified
Journal Article
Closed access
LOLouise S. Owen
Louise S. Owen
BMBrett J. Manley
Brett J. Manley

15 March 2015 in Trials
Verified
Journal Article
Open access
PDF file
EFElizabeth E Foglia
Elizabeth E Foglia
LOLouise S Owen
Louise S Owen
MTMarta Thio
Marta Thio
SRSarah J Ratcliffe
Sarah J Ratcliffe
gianluca listagianluca lista
gianluca lista
HKHaresh Kirpalani
Haresh Kirpalani
Extremely preterm infants require assistance recruiting the lung to establish a functional residual capacity after birth. Sustained inflation (SI) combined with positive end expiratory pressure (PEEP) may be a superior method of aerating the lung compared with intermittent positive pressure ventilation (IPPV) with PEEP in extremely preterm infants. The Sustained Aeration of Infant Lungs (SAIL) trial was designed to study this question. This multisite prospective randomized controlled unblinded trial will recruit 600 infants of 23 to 26 weeks gestational age who require respiratory support at birth. Infants in both arms will be treated with PEEP 5 to 7 cm H2O throughout the resuscitation. The study intervention consists of performing an initial SI (20 cm H20 for 15 seconds) followed by a second SI (25 cm H2O for 15 seconds), and then PEEP with or without IPPV, as needed. The control group will be treated with initial IPPV with PEEP. The primary outcome is the combined endpoint of bronchopulmonary dysplasia or death at 36 weeks post-menstrual age. www.clinicaltrials.gov , Trial identifier NCT02139800 , Registered 13 May 2014

20 May 2010 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Verified
Journal Article
Closed access
PDF file
LOL S Owen
L S Owen
CMC J Morley
C J Morley
PDP G Davis
P G Davis
Background: Nasal intermittent positive pressure ventilation (NIPPV) is a mode of non-invasive respiratory support. Its mechanisms of action and optimal delivery techniques are unknown. Aim: This observational study aimed to investigate and quantify delivered peak pressures during non-synchronised ventilator-generated NIPPV. Methods: Infants born below 30 weeks gestation receiving ventilator-generated NIPPV delivered via Hudson prongs were recruited. Intraprong pressure, change in tidal volume, respiratory rate, oxygen saturations, inspired oxygen and video images were recorded. Results: Eleven infants (four infants were female) of median (interquartile range; IQR) gestational age 25±3 (25±2 26+/-0) weeks and birth weight 732 (699–895) g, were studied at 24 (19–41) days of age. Six infants, with set peak pressure (peak inflation pressure; PIP) of 20 cm H2O, received a median pressure of 15.9 (IQR 13.6–17.9) cm H2O. 37% of inflations were delivered at least 5 cm H2O below set PIP. 12.7% of inflations were delivered above set PIP. Five infants with set PIP of 25 cm H2O received a median PIP of 17.2 (IQR 15.0–18.3) cm H2O. 83% of inflations were delivered at least 5 cm H2O below set PIP, with 6.1% delivered higher than set PIP. The difference in delivered PIP between the groups was 1.3 cm H2O. PIP was highest and most variable when the infant was moving. Delivered PIP did not vary whether it coincided with spontaneous inspiration or expiration. Conclusion: During ventilator-generated non-synchronised NIPPV delivered PIP was variable and frequently lower than set PIP. Delivered PIP was occasionally greater than set PIP.