Walter H. Lippincott

Walter H. Lippincott

Auto-generated profile, based on publicly available information

Walter H. Lippincott

University of California, Santa Barbara

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2019 in Physical Review D
Verified
Journal Article
Closed access
PDF file
CAC. Amole
C. Amole
Miguel ArdidMiguel Ardid
Miguel Ardid
IAI. J. Arnquist
I. J. Arnquist
DAD. M. Asner
D. M. Asner
DBD. Baxter
D. Baxter
PCPICO Collaboration
PICO Collaboration
Final results are reported from operation of the PICO-60 C3F8 dark matter detector, a bubble chamber filled with 52 kg of C3F8 located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.2×10−41  cm2 for a 25 GeV WIMP, improving on previous PICO results for 3–5 GeV WIMPs by an order of magnitude.

4 March 2020 in Physical Review D
Verified
Journal Article
Closed access
PDF file
DAD. S. Akerib
D. S. Akerib
CAC. W. Akerlof
C. W. Akerlof
SAS. K. Alsum
S. K. Alsum
HAH. M. Araújo
H. M. Araújo
MAM. Arthurs
M. Arthurs
LCLUX-ZEPLIN Collaboration
LUX-ZEPLIN Collaboration
LUX-ZEPLIN (LZ) is a next-generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7 tonnes, LZ will search primarily for low-energy interactions with weakly interacting massive particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector. For a 1000 live day run using a 5.6-tonne fiducial mass, LZ is projected to exclude at 90% confidence level spin-independent WIMP-nucleon cross sections above 1.4×10−48  cm2 for a 40  GeV/c2 mass WIMP. Additionally, a 5σ discovery potential is projected, reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of 2.3×10−43  cm2 (7.1×10−42  cm2) for a 40  GeV/c2 mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020.

23 June 2017 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
CAC. Amole
C. Amole
Miguel ArdidMiguel Ardid
Miguel Ardid
IAI. J. Arnquist
I. J. Arnquist
DAD. M. Asner
D. M. Asner
DBDaniel Baxter
Daniel Baxter
PCPICO Collaboration
PICO Collaboration
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C3F8 located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO−60 C3F8 exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than one event per month. A blind analysis of an efficiency-corrected 1167-kg day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.4×10−41  cm2 for a 30−GeV c−2 WIMP, more than 1 order of magnitude improvement from previous PICO results.

5 September 2012 in Physical Review D
Verified
Journal Article
Open access
PDF file
EBE. Behnke
E. Behnke
JBJ. Behnke
J. Behnke
SBS. J. Brice
S. J. Brice
DBD. Broemmelsiek
D. Broemmelsiek
JCJ. I. Collar
J. I. Collar
EVEric Vazquez-Jauregui
Eric Vazquez-Jauregui
New data are reported from the operation of a 4.0-kg CF3I bubble chamber in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha-decay background events from single nuclear recoils has been confirmed, with a lower bound of >99.3% rejection of alpha-decay events. Twenty single nuclear recoil event candidates and three multiple bubble events were observed during a total exposure of 553 kg-days distributed over three different bubble nucleation thresholds. The effective exposure for single bubble recoil-like events was 437.4 kg-days. A neutron background internal to the apparatus, of known origin, is estimated to account for five single nuclear recoil events and is consistent with the observed rate of multiple bubble events. The remaining excess of single bubble events exhibits characteristics indicating the presence of an additional background. These data provide new direct detection constraints on WIMP-proton spin-dependent scattering for WIMP masses >20  GeV/c2 and demonstrate significant sensitivity for spin-independent interactions.

15 October 2021 in The European Physical Journal C
Verified
Journal Article
Open access
PDF file
DBD. Baxter
D. Baxter
IBI. M. Bloch
I. M. Bloch
EBE. Bodnia
E. Bodnia
XCX. Chen
X. Chen
JCJ. Conrad
J. Conrad
NZN. Zhou
N. Zhou
The field of dark matter detection is a highly visible and highly competitive one. In this paper, we propose recommendations for presenting dark matter direct detection results particularly suited for weak-scale dark matter searches, although we believe the spirit of the recommendations can apply more broadly to searches for other dark matter candidates, such as very light dark matter or axions. To translate experimental data into a final published result, direct detection collaborations must make a series of choices in their analysis, ranging from how to model astrophysical parameters to how to make statistical inferences based on observed data. While many collaborations follow a standard set of recommendations in some areas, for example the expected flux of dark matter particles (to a large degree based on a paper from Lewin and Smith in 1995), in other areas, particularly in statistical inference, they have taken different approaches, often from result to result by the same collaboration. We set out a number of recommendations on how to apply the now commonly used Profile Likelihood Ratio method to direct detection data. In addition, updated recommendations for the Standard Halo Model astrophysical parameters and relevant neutrino fluxes are provided. The authors of this note include members of the DAMIC, DarkSide, DARWIN, DEAP, LZ, NEWS-G, PandaX, PICO, SBC, SENSEI, SuperCDMS, and XENON collaborations, and these collaborations provided input to the recommendations laid out here. Wide-spread adoption of these recommendations will make it easier to compare and combine future dark matter results.

1 February 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
DAD.S. Akerib
D.S. Akerib
CAC.W. Akerlof
C.W. Akerlof
DAD.Yu. Akimov
D.Yu. Akimov
AAA. Alquahtani
A. Alquahtani
SAS.K. Alsum
S.K. Alsum
CZC. Zhang
C. Zhang