Douglas D. Koch

Douglas D. Koch

Auto-generated profile, based on publicly available information

Douglas D. Koch

Baylor College of Medicine

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2012 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
DKDouglas D. Koch
Douglas D. Koch
SAShazia F. Ali
Shazia F. Ali
MWMitchell P. Weikert
Mitchell P. Weikert
MSMariko Shirayama
Mariko Shirayama
RJRichard Jenkins
Richard Jenkins
LWLi Wang
Li Wang
To determine the contribution of posterior corneal astigmatism to total corneal astigmatism and the error in estimating total corneal astigmatism from anterior corneal measurements only using a dual-Scheimpflug analyzer. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Case series. Total corneal astigmatism was calculated using ray tracing, corneal astigmatism from simulated keratometry, anterior corneal astigmatism, and posterior corneal astigmatism, and the changes with age were analyzed. Vector analysis was used to assess the error produced by estimating total corneal astigmatism from anterior corneal measurements only. The study analyzed 715 corneas of 435 consecutive patients. The mean magnitude of posterior corneal astigmatism was -0.30 diopter (D). The steep corneal meridian was aligned vertically (60 to 120 degrees) in 51.9% of eyes for the anterior surface and in 86.6% for the posterior surface. With increasing age, the steep anterior corneal meridian tended to change from vertical to horizontal, while the steep posterior corneal meridian did not change. The magnitudes of anterior and posterior corneal astigmatism were correlated when the steeper anterior meridian was aligned vertically but not when it was aligned horizontally. Anterior corneal measurements underestimated total corneal astigmatism by 0.22 @ 180 and exceeded 0.50 D in 5% of eyes. Ignoring posterior corneal astigmatism may yield incorrect estimation of total corneal astigmatism. Selecting toric intraocular lenses based on anterior corneal measurements could lead to overcorrection in eyes that have with-the-rule astigmatism and undercorrection in eyes that have against-the-rule astigmatism. The authors received research support from Ziemer Group. In addition, Dr. Koch has a financial interest with Alcon Laboratories, Inc., Abbott Medical Optics, Inc., Calhoun Vision, Inc., NuLens, and Optimedica Corp.

1 December 2013 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
DKDouglas D. Koch
Douglas D. Koch
RJRichard B. Jenkins
Richard B. Jenkins
MWMitchell P. Weikert
Mitchell P. Weikert
EYElizabeth Yeu
Elizabeth Yeu
LWLi Wang
Li Wang
To evaluate the impact of posterior corneal astigmatism on outcomes with toric intraocular lenses (IOLs). Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Case series. Corneal astigmatism was measured using 5 devices before and 3 weeks after cataract surgery. Toric IOL alignment was recorded at surgery and at the slitlamp 3 weeks postoperatively. The actual corneal astigmatism was calculated based on refractive astigmatism 3 weeks postoperatively and the effective toric power calculated with the Holladay 2 formula. The prediction error was calculated as the difference between the astigmatism measured by each device and the actual corneal astigmatism. Vector analysis was used in all calculations. With the IOLMaster, Lenstar, Atlas, manual keratometer, and Galilei (combined Placido-dual Scheimpflug analyzer), the mean prediction errors (D) were, respectively, 0.59 @ 89.7, 0.48 @ 91.2, 0.51 @ 78.7, 0.62 @ 97.2, and 0.57 @ 93.9 for with-the-rule (WTR) astigmatism (60 to 120 degrees), and 0.17 @ 86.2, 0.23 @ 77.7, 0.23 @ 91.4, 0.41 @ 58.4, and 0.12 @ 7.3 for against-the-rule (ATR) astigmatism (0 to 30 degrees and 150 to 180 degrees). In the WTR eyes, there were significant WTR prediction errors (0.5 to 0.6 diopters [D]) by all devices. In ATR eyes, WTR prediction errors were 0.2 to 0.3 D by all devices except the Placido-dual Scheimpflug analyzer (all P<.05 with Bonferroni correction). Corneal astigmatism was overestimated in WTR by all devices and underestimated in ATR by all except the Placido-dual Scheimpflug analyzer. A new toric IOL nomogram is proposed.

1 December 2015 in Ophthalmology
Verified
Journal Article
Closed access
LWLi Wang
Li Wang
MTMaolong Tang
Maolong Tang
DHDavid Huang
David Huang
MWMitchell P. Weikert
Mitchell P. Weikert
DKDouglas D. Koch
Douglas D. Koch

1 October 2019 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Open access
LWLi Wang
Li Wang
TSTatyana Spektor
Tatyana Spektor
RSRodrigo G. de Souza
Rodrigo G. de Souza
DKDouglas D. Koch
Douglas D. Koch
To compare the accuracy of total keratometry (TK) and standard keratometry (K) from a swept-source optical coherence tomography biometer for intraocular lens (IOL) power calculation in eyes with previous corneal refractive surgery. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Retrospective case series. The differences between the TK and K and their association with K were assessed. For IOL power calculation, combinations of 1) K with Haigis, Haigis-L, and Barrett True-K, and 2) TK with Haigis (Haigis-TK) were used. The mean absolute error (MAE) and the percentages of eyes within prediction errors of ± 0.50 diopters (D), ± 1.00 D, and ± 2.00 D were calculated. The study comprised 129 eyes. For Haigis, Haigis-L, Barrett True-K, and Haigis-TK, respectively, the MAEs were 0.72 D, 0.61 D, 0.54 D, and 0.50 D in the myopic laser in situ keratomileusis (LASIK)/photorefractive keratectomy (PRK) group, and 0.74 D, 0.68 D, 0.71 D, and 0.70 D in hyperopic LASIK/PRK group. For the radial keratotomy (RK) eyes, the MAEs were 0.66 D, 0.71 D, and 0.72 D for the Haigis, Barrett True-K, and Haigis-TK formulas, respectively. In the myopic LASIK/PRK group, the Barrett True-K and Haigis-TK produced significantly lower MAEs than did Haigis (P < .05). In the hyperopic LASIK/PRK and RK groups, there were no significant differences between the formulas in MAEs and percentages of eyes within the above prediction errors. The performance of the combination of Haigis and TK in refractive prediction was comparable with Haigis-L and Barrett True-K in eyes with previous corneal refractive surgery.

1 November 2021 in Ophthalmology
Verified
Journal Article
Closed access
LWLi Wang
Li Wang
DKDouglas D. Koch
Douglas D. Koch

1 January 2019 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
LWLi Wang
Li Wang
RSRodrigo Guimaraes de Souza
Rodrigo Guimaraes de Souza
MWMitchell P. Weikert
Mitchell P. Weikert
DKDouglas D. Koch
Douglas D. Koch
To evaluate crystalline lens and intraocular lens (IOL) tilt using a swept-source optical coherence tomography (SS-OCT) biometer (IOLMaster 700). Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Retrospective case series. The study patients were evaluated for 1) repeatability of the crystalline lens tilt measurement, 2) preoperative crystalline lens and postoperative IOL tilt in right eyes, 3) mirror symmetry between right eyes and left eyes, 4) the correlation between preoperative crystalline lens and postoperative IOL tilt, and 5) the correlation between the magnitude of lens tilt and ocular parameters. The study comprised 333 patients. The repeatability was 0.1 degrees for tilt magnitude and 3.0 degrees for tilt direction. Both the crystalline lens and IOL had anterior tilt of the nasal portion with mean tilt magnitudes of 3.7 degrees ± 1.1 (SD) (range 0.4 to 6.9 degrees) for the crystalline lens and 4.9 ± 1.8 degrees (range 1.6 to 10.7 degrees) for the IOL. There was mirror symmetry between right eyes and left eyes. The mean IOL tilt magnitude exceeded crystalline lens tilt by 1.2 ± 1.1 degrees (range -3.2 to 4.0 degrees), and the 2 values were significantly correlated (all P < .01). The magnitude of crystalline lens tilt significantly increased with decreasing axial length and with increasing angle α (all P < .05). The repeatability of crystalline lens tilt measurements using the SS-OCT biometer was excellent. There was mirror symmetry between the right eyes and left eyes. Preoperative crystalline lens tilt could be used to predict the postoperative IOL tilt. The lens tilt magnitude was greater in short eyes and in eyes with larger angle α.