Pieter Buma

Pieter Buma

Auto-generated profile, based on publicly available information

Pieter Buma

Radboud University Nijmegen Medical Centre

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2004 in Biomaterials
Verified
Journal Article
Closed access
PBP. Buma
P. Buma
NRN.N. Ramrattan
N.N. Ramrattan
TTT.G. van Tienen
T.G. van Tienen
RVR.P.H. Veth
R.P.H. Veth

1 August 2003 in Biomaterials
Verified
Journal Article
Closed access
PBPieter Buma
Pieter Buma
JPJeroen S. Pieper
Jeroen S. Pieper
TTTony van Tienen
Tony van Tienen
JSJob L.C. van Susante
Job L.C. van Susante
PKPeter M. van der Kraan
Peter M. van der Kraan
TKToin H. van Kuppevelt
Toin H. van Kuppevelt

31 July 2008 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
RWRoy T. C. Welsing
Roy T. C. Welsing
TTTony G. van Tienen
Tony G. van Tienen
NRNavin Ramrattan
Navin Ramrattan
RHRalf Heijkants
Ralf Heijkants
ASArend Jan Schouten
Arend Jan Schouten
PBPieter Buma
Pieter Buma
Background: Replacement of the meniscus by an implant could potentially avoid cartilage degeneration. Hypothesis: An implant of degradable polycaprolacton-polyurethane should act as a temporary scaffold enabling regeneration of a new meniscus by slow degradation of the polymer and simultaneous in-growth and differentiation of tissues into the typical cartilage-like tissue of the meniscus. Study Design: Controlled laboratory study. Methods: In 13 dogs’ knees, the lateral meniscus was replaced with a porous polymer implant (6 and 7 for 6- and 24-month follow-up, respectively); in 7 knees only a meniscectomy was performed. In 6 knees, no surgery was performed. After 6 and 24 months, the implants and the articular cartilage were histologically evaluated. Compression-stress tests were performed on implant biopsy specimens. Results: The implants were fully integrated into the tissue without formation of a capsule. The foreign body reaction did not exceed grade I. Differentiation from fibrous- to cartilage-like tissue was pronounced after 24 months. Viable cells were particularly absent after 24 months in central parts of the most anterior part of the scaffold. The mechanical properties of the implants were intermediate between the scaffold before implantation and native meniscus tissue and were not different between 6 and 24 months. After both 6 and 24 months, small areas of the implant were not covered with tissue. Cartilage degeneration was not prevented. Conclusion: A final remodeling of tissue into neomeniscus tissue could not take place since the original structure of the polymer was still present after 24 months. The implant did not prevent cartilage degradation. Several factors are discussed that may be responsible for this. Clinical Relevance: Although clinical application of a polymer implant for the replacement of the entire meniscus is not supported by this study, the authors strongly believe in the concept, but further improvements in the implant and surgical technique are needed before such an implant can be recommended for human clinical use.

26 October 2012 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
AVAnne Christiane Theodora Vrancken
Anne Christiane Theodora Vrancken
PBPieter Buma
Pieter Buma
TTTony George van Tienen
Tony George van Tienen

1 April 2004 in Biomaterials
Verified
Journal Article
Closed access
PBPieter Buma
Pieter Buma
WSWillem Schreurs
Willem Schreurs
NVNico Verdonschot
Nico Verdonschot

21 December 2012 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Closed access
PDF file
JBJ. E. Biemond
J. E. Biemond
GHGerjon Hannink
Gerjon Hannink
NVN. Verdonschot
N. Verdonschot
PBP. Buma
P. Buma