1 October 2011 in British Journal of Radiology
The purpose of this study was to develop and validate a computer model to produce realistic simulated computed radiography (CR) chest images using CT data sets of real patients. Anatomical noise, which is the limiting factor in determining pathology in chest radiography, is realistically simulated by the CT data, and frequency-dependent noise has been added post-digitally reconstructed radiograph (DRR) generation to simulate exposure reduction. Realistic scatter and scatter fractions were measured in images of a chest phantom acquired on the CR system simulated by the computer model and added post-DRR calculation. The model has been validated with a phantom and patients and shown to provide predictions of signal-to-noise ratios (SNRs), tissue-to-rib ratios (TRRs: a measure of soft tissue pixel value to that of rib) and pixel value histograms that lie within the range of values measured with patients and the phantom. The maximum difference in measured SNR to that calculated was 10%. TRR values differed by a maximum of 1.3%. Experienced image evaluators have responded positively to the DRR images, are satisfied they contain adequate anatomical features and have deemed them clinically acceptable. Therefore, the computer model can be used by image evaluators to grade chest images presented at different tube potentials and doses in order to optimise image quality and patient dose for clinical CR chest radiographs without the need for repeat patient exposures.
1 July 2013 in British Journal of Radiology
The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson's correlation coefficient. Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, p<0.033) and eDE (R=0.77, p<0.008) were observed. Medical physics experts may use the physical image quality metrics described here in quality assurance programmes and optimisation studies with a degree of confidence that they reflect the clinical image quality in chest CR images acquired without an antiscatter grid. A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography.
25 May 2004 in Journal of Applied Clinical Medical Physics
We are implementing the use of magnetic resonance (MR) images for head and neck radiotherapy planning, which involves their registration with computed tomography (CT). The quality assurance (QA) of the registration process was an initial step of this program.A phantom was built, and appropriate materials were identified to produce clinically relevant MR and contrast for its constituent “anatomy.” We performed a characterization of the distortion detectable within our phantom. Finally, we assessed the accuracy of image registration by contouring structures in the registered/fused data sets using the treatment planning system. Each structure was contoured using each modality, in turn, blind of the other. The position, area, and perimeter of each structure were assessed as a measure of accuracy of the entire image registration process.Distortion effects in the MR image were shown to be minimized by choosing a suitable receiver bandwidth. Remaining distortion was deemed clinically acceptable within of the magnetic field isocenter. A coefficient of agreement (A) analysis gave values to be within 9% of unity, where urn:x-wiley:15269914:media:acm20025:acm20025-math-0005 is the ratio of the area/perimeter of a particular structure on CT to that on MR. The center of each structure of interest agreed to within 1.8 mm.A QA process has been developed to assess the accuracy of using multimodality image registration in the planning of radiotherapy for the head and neck; we believe its introduction is feasible and safe.PACS numbers: 87.53.Xd, 87.57.Gg, 87.59.Fm; 87.61.‐c, 87.66.Xa
1 November 2015 in British Journal of Radiology
Objective:The purpose of this study was to develop size-based radiotherapy kilovoltage cone beam CT (CBCT) protocols for the pelvis.Methods:Image noise was measured in an elliptical phantom of varying size for a range of exposure factors. Based on a previously defined “small pelvis” reference patient and CBCT protocol, appropriate exposure factors for small, medium, large and extra-large patients were derived which approximate the image noise behaviour observed on a Philips CT scanner (Philips Medical Systems, Best, Netherlands) with automatic exposure control (AEC). Selection criteria, based on maximum tube current–time product per rotation selected during the radiotherapy treatment planning scan, were derived based on an audit of patient size.Results:It has been demonstrated that 110 kVp yields acceptable image noise for reduced patient dose in pelvic CBCT scans of small, medium and large patients, when compared with manufacturer's default settings (125 kVp). Conversely, extra-large patients require inc...
1 September 2012 in British Journal of Radiology
The purpose of this study was to derive an optimum radiographic technique for computed radiography (CR) chest imaging using a digitally reconstructed radiograph computer simulator. The simulator is capable of producing CR chest radiographs of adults with various tube potentials, receptor doses and scatter rejection. Four experienced image evaluators graded images of average and obese adult patients at different potentials (average-sized, n=50; obese, n=20), receptor doses (n=10) and scatter rejection techniques (average-sized, n=20; obese, n=20). The quality of the images was evaluated using visually graded analysis. The influence of rib contrast was also assessed. For average-sized patients, image quality improved when tube potential was reduced compared with the reference (102 kVp). No scatter rejection was indicated. For obese patients, it has been shown that an antiscatter grid is indicated, and should be used in conjunction with as low a tube potential as possible (while allowing exposure times <20 ms). It is also possible to reduce receptor air kerma by 50% without adversely influencing image quality. Rib contrast did not interfere at any tube potential. A virtual clinical trial has been performed with simulated chest CR images. Results indicate that low tube potentials (<102 kVp) are optimal for average and obese adults, the former acquired without scatter rejection, the latter with an anti-scatter grid. Lower receptor (and therefore patient doses) than those used clinically are possible while maintaining adequate image quality.
5 November 2015 in Physics in Medicine & Biology
This work assessed the appropriateness of the signal-to-noise ratio improvement factor ( K SNR ) as a metric for the optimisation of computed radiography (CR) of the chest. The results of a previous study in which four experienced image evaluators graded computer simulated chest images using a visual grading analysis scoring (VGAS) scheme to quantify the benefit of using an anti-scatter grid were used for the clinical image quality measurement (number of simulated patients = 80). The K SNR was used to calculate the improvement in physical image quality measured in a physical chest phantom. K SNR correlation with VGAS was assessed as a function of chest region (lung, spine and diaphragm/retrodiaphragm), and as a function of x-ray tube voltage in a given chest region. The correlation of the latter was determined by the Pearson correlation coefficient. VGAS and K SNR image quality metrics demonstrated no correlation in the lung region but did show correlation in the spine and diaphragm/retrodiaphragmatic regions. However, there was no correlation as a function of tube voltage in any region; a Pearson correlation coefficient (R) of −0.93 ( p = 0.015) was found for lung, a coefficient (R) of −0.95 ( p = 0.46) was found for spine, and a coefficient (R) of −0.85 ( p = 0.015) was found for diaphragm. All demonstrate strong negative correlations indicating conflicting results, i.e. K SNR increases with tube voltage but VGAS decreases. Medical physicists should use the K SNR metric with caution when assessing any potential improvement in clinical chest image quality when introducing an anti-scatter grid for CR imaging, especially in the lung region. This metric may also be a limited descriptor of clinical chest image quality as a function of tube voltage when a grid is used routinely.