Isabel Gonçalves

Isabel Gonçalves

Auto-generated profile, based on publicly available information

Isabel Gonçalves

Instituto Tecnológico e Nuclear (ITN)

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2013 in The European Physical Journal A
Verified
Journal Article
Open access
PDF file
CGCarlos Guerrero
Carlos Guerrero
ATA. Tsinganis
A. Tsinganis
EBE. Berthoumieux
E. Berthoumieux
MBM. Barbagallo
M. Barbagallo
FBF. Belloni
F. Belloni
PŽP. Žugec
P. Žugec
The neutron time-of-flight facility n_TOF features a white neutron source produced by spallation through 20GeV/ cprotons impinging on a lead target. The facility, aiming primarily at the measurement...

1 April 2004 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
UAU Abbondanno
U Abbondanno
GAG Aerts
G Aerts
HAH Alvarez
H Alvarez
SAS Andriamonje
S Andriamonje
AAA Angelopoulos
A Angelopoulos
LZL Zanini
L Zanini

1 September 2009 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
CGCarlos Guerrero
Carlos Guerrero
UAU. Abbondanno
U. Abbondanno
GAG. Aerts
G. Aerts
HÁH. Álvarez
H. Álvarez
FÁF. Álvarez-Velarde
F. Álvarez-Velarde
KWK. Wisshak
K. Wisshak

17 March 2011 in Physical Review C
Verified
Journal Article
Open access
PDF file
CLC. Lederer
C. Lederer
NCN. Colonna
N. Colonna
CDCésar Domingo-Pardo
César Domingo-Pardo
FGF. Gunsing
F. Gunsing
FKF. Käppeler
F. Käppeler
KWK. Wisshak
K. Wisshak
The cross section of the reaction Au197(n,γ) was measured with the time-of-flight technique at the n_TOF (neutron time-of-flight) facility in the unresolved resonance region between 5 and 400 keV using a pair of C6D6 (where D denotes H2) liquid scintillators for the detection of prompt capture γ rays. The results with a total uncertainty of 3.9%–6.7 % for a resolution of 20 bins per energy decade show fair agreement with the Evaluated Nuclear Data File Version B-VII.0 (ENDF/B-VII.0), which contains the standard evaluation. The Maxwellian-averaged cross section (MACS) at 30 keV is in excellent agreement with the one according to the ENDF/B-VII.0 evaluation and 4.7% higher than the MACS measured independently by activation technique. Structures in the cross section, which had also been reported earlier, have been interpreted as being due to clusters of resonances.

14 October 2004 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
UAU. Abbondanno
U. Abbondanno
GAG. Aerts
G. Aerts
FAF. Alvarez-Velarde
F. Alvarez-Velarde
HÁH. Álvarez-Pol
H. Álvarez-Pol
SAS. Andriamonje
S. Andriamonje
KWK. Wisshak
K. Wisshak
TheSm151(n,γ)Sm152 cross section has been measured at the spallation neutron facility n_TOF at CERN in the energy range from 1 eV to 1 MeV. The new facility combines excellent resolution in neutron time-of-flight, low repetition rates, and an unsurpassed instantaneous luminosity, resulting in rather favorable signal/background ratios. The Sm151 cross section is of importance for characterizing neutron capture nucleosynthesis in asymptotic giant branch stars. At a thermal energy of   kT=30  keV the Maxwellian averaged cross section of this unstable isotope (t1/2=93  yr) was determined to be 3100±160  mb, significantly larger than theoretical predictions.

27 April 2010 in Physical Review C
Verified
Journal Article
Open access
PDF file
CMCristian Massimi
Cristian Massimi
CDCésar Domingo-Pardo
César Domingo-Pardo
GVG. Vannini
G. Vannini
LAL. Audouin
L. Audouin
CGCarlos Guerrero
Carlos Guerrero
KWK. Wisshak
K. Wisshak
The (n,γ) cross section of Au197 has been measured at n_TOF in the resolved resonance region, up to 5 keV, with the aim of improving the accuracy in an energy range where it is not yet considered standard. The measurements were performed with two different experimental setup and detection techniques, the total energy method based on C6 D6 detectors, and the total absorption calorimetry based on a 4π BaF2 array. By comparing the data collected with the two techniques, two accurate sets of neutron-capture yields have been obtained, which could be the basis for a new evaluation leading to an extended cross-section standard. Overall good agreement is found between the n_TOF results and evaluated cross sections, with some significant exceptions for small resonances. A few resonances not included in the existing databases have also been observed.