Gregory M. Greetham

Gregory M. Greetham

Auto-generated profile, based on publicly available information

Gregory M. Greetham

Central Laser Facility, Research Complex at Harwell STFC Rutherford Appleton Laboratory Harwell Campus Didcot Oxfordshire UK

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2010 in Applied Spectroscopy
Verified
Journal Article
Closed access
PDF file
GGGregory M. Greetham
Gregory M. Greetham
PBPierre Burgos
Pierre Burgos
QCQian Cao
Qian Cao
ICIan P. Clark
Ian P. Clark
PCPeter S. Codd
Peter S. Codd
MTMichael Towrie
Michael Towrie
We report the development of a high-sensitivity time-resolved infrared and Raman spectrometer with exceptional experimental flexibility based on a 10-kHz synchronized dual-arm femtosecond and picosecond laser system. Ultrafast high-average-power titanium sapphire lasers and optical parametric amplifiers provide wavelength tuning from the ultraviolet (UV) to the mid-infrared region. Customized silicon, indium gallium arsenide, and mercury cadmium telluride linear array detectors are provided to monitor the probe laser intensity in the UV to mid-infrared wavelength range capable of measuring changes in sample absorbance of ΔOD ∼ 10−5 in 1 second. The system performance is demonstrated for the time-resolved infrared, two-dimensional (2D) infrared, and femtosecond stimulated Raman spectroscopy techniques with organometallic intermediates, organic excited states, and the dynamics of the tertiary structure of DNA.

1 October 2012 in Review of Scientific Instruments
Verified
Journal Article
Closed access
GGG. M. Greetham
G. M. Greetham
DSD. Sole
D. Sole
ICI. P. Clark
I. P. Clark
APA. W. Parker
A. W. Parker
MPM. R. Pollard
M. R. Pollard
MTM. Towrie
M. Towrie
Time-resolved multiple probe spectroscopy combines optical, electronic, and data acquisition capabilities to enable measurement of picosecond to millisecond time-resolved spectra within a single experiment, using a single activation pulse. This technology enables a wide range of dynamic processes to be studied on a single laser and sample system. The technique includes a 1 kHz pump, 10 kHz probe flash photolysis-like mode of acquisition (pump–probe–probe–probe, etc.), increasing the amount of information from each experiment. We demonstrate the capability of the instrument by measuring the photolysis of tungsten hexacarbonyl (W(CO)6) monitored by IR absorption spectroscopy, following picosecond vibrational cooling of product formation through to slower bimolecular diffusion reactions on the microsecond time scale.

17 February 2016 in Applied Spectroscopy
Verified
Journal Article
Closed access
GGGregory M. Greetham
Gregory M. Greetham
PDPaul M. Donaldson
Paul M. Donaldson
CNCharlie Nation
Charlie Nation
ISIgor V. Sazanovich
Igor V. Sazanovich
ICIan P. Clark
Ian P. Clark
MTMichael Towrie
Michael Towrie
We present a dual-amplifier laser system for time-resolved multiple-probe infrared (IR) spectroscopy based on the ytterbium potassium gadolinium tungstate (Yb:KGW) laser medium. Comparisons are made between the ytterbium-based technology and titanium sapphire laser systems for time-resolved IR spectroscopy measurements. The 100 kHz probing system provides new capability in time-resolved multiple-probe experiments, as more information is obtained from samples in a single experiment through multiple-probing. This method uses the high repetition-rate probe pulses to repeatedly measure spectra at 10 µs intervals following excitation allowing extended timescales to be measured routinely along with ultrafast data. Results are presented showing the measurement of molecular dynamics over >10 orders of magnitude in timescale, out to 20 ms, with an experimental time response of <200 fs. The power of multiple-probing is explored through principal component analysis of repeating probe measurements as a novel method for removing noise and measurement artifacts.

14 November 2024 in The Journal of Physical Chemistry B
Verified
Journal Article
Open access
CGCamilla Gajo
Camilla Gajo
DSDarya Shchepanovska
Darya Shchepanovska
JJJacob F. Jones
Jacob F. Jones
GKGabriel Karras
Gabriel Karras
PMPartha Malakar
Partha Malakar
TOThomas A. A. Oliver
Thomas A. A. Oliver
Nile Red is a fluorescent dye used extensively in bioimaging due to its strong solvatochromism. The photophysics underpinning Nile Red's fluorescence has been disputed for decades, with some studies claiming that the dye fluoresces from two excited states and/or that the main emissive state is twisted and intramolecular charge-transfer (ICT) in character as opposed to planar ICT (PICT). To resolve these long-standing questions, a combined experimental and theoretical study was used to unravel the mechanism of Nile Red's fluorescence. Time-resolved fluorescence measurements indicated that Nile Red emission occurs from a single excited state. Theoretical calculations revealed no evidence for a low-lying TICT state, with the S1 minimum corresponding to a PICT state. Ultrafast pump-probe spectroscopic data contained no signatures associated with an additional excited state involved in the fluorescence decay of Nile Red. Collectively, these data in polar and nonpolar solvents refute dual fluorescence in Nile Red and definitively demonstrate that emission occurs from a PICT state.

4 April 2024 in Journal of the American Chemical Society
Verified
Journal Article
Open access
NLNicholas A. Lau
Nicholas A. Lau
DGDeborin Ghosh
Deborin Ghosh
SBSusannah Bourne-Worster
Susannah Bourne-Worster
RKRhea Kumar
Rhea Kumar
WWWilliam A. Whitaker
William A. Whitaker
HFHelen H. Fielding
Helen H. Fielding
Nitroaromatic compounds are major constituents of the brown carbon aerosol particles in the troposphere that absorb near-ultraviolet (UV) and visible solar radiation and have a profound effect on the Earth's climate. The primary sources of brown carbon include biomass burning, forest fires, and residential burning of biofuels, and an important secondary source is photochemistry in aqueous cloud and fog droplets. Nitrobenzene is the smallest nitroaromatic molecule and a model for the photochemical behavior of larger nitroaromatic compounds. Despite the obvious importance of its droplet photochemistry to the atmospheric environment, there have not been any detailed studies of the ultrafast photochemical dynamics of nitrobenzene in aqueous solution. Here, we combine femtosecond transient absorption spectroscopy, time-resolved infrared spectroscopy, and quantum chemistry calculations to investigate the primary steps following the near-UV (λ ≥ 340 nm) photoexcitation of aqueous nitrobenzene. To understand the role of the surrounding water molecules in the photochemical dynamics of nitrobenzene, we compare the results of these investigations with analogous measurements in solutions of methanol, acetonitrile, and cyclohexane. We find that vibrational energy transfer to the aqueous environment quenches internal excitation, and therefore, unlike the gas phase, we do not observe any evidence for formation of photoproducts on timescales up to 500 ns. We also find that hydrogen bonding between nitrobenzene and surrounding water molecules slows the S1/S0 internal conversion process.

20 December 2013 in The Journal of Physical Chemistry Letters
Verified
Journal Article
Open access
RBRichard Brust
Richard Brust
AHAllison Haigney
Allison Haigney
ALAndras Lukacs
Andras Lukacs
AGAgnieszka Gil
Agnieszka Gil
SHShahrier Hossain
Shahrier Hossain
PTPeter J. Tonge
Peter J. Tonge
Acinetobacter baumannii is an important human pathogen that can form biofilms and persist under harsh environmental conditions. Biofilm formation and virulence are modulated by blue light, which is thought to be regulated by a BLUF protein, BlsA. To understand the molecular mechanism of light sensing, we have used steady-state and ultrafast vibrational spectroscopy to compare the photoactivation mechanism of BlsA to the BLUF photosensor AppA from Rhodobacter sphaeroides. Although similar photocycles are observed, vibrational data together with homology modeling identify significant differences in the β5 strand in BlsA caused by photoactivation, which are proposed to be directly linked to downstream signaling.