Tom Van Hoof

Tom Van Hoof

Auto-generated profile, based on publicly available information

Tom Van Hoof

Department of Anatomy, Ghent University, Ghent, Belgium

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2016 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
JVJoris Van de Velde
Joris Van de Velde
JWJohan Wouters
Johan Wouters
TVTom Vercauteren
Tom Vercauteren
WGWerner De Gersem
Werner De Gersem
EAEric Achten
Eric Achten
THTom Van Hoof
Tom Van Hoof
The present study aimed to define the optimal number of atlases for automatic multi-atlas-based brachial plexus (BP) segmentation and to compare Simultaneous Truth and Performance Level Estimation (STAPLE) label fusion with Patch label fusion using the ADMIRE® software. The accuracy of the autosegmentations was measured by comparing all of the generated autosegmentations with the anatomically validated gold standard segmentations that were developed using cadavers. Twelve cadaver computed tomography (CT) atlases were used for automatic multi-atlas-based segmentation. To determine the optimal number of atlases, one atlas was selected as a patient and the 11 remaining atlases were registered onto this patient using a deformable image registration algorithm. Next, label fusion was performed by using every possible combination of 2 to 11 atlases, once using STAPLE and once using Patch. This procedure was repeated for every atlas as a patient. The similarity of the generated automatic BP segmentations and the gold standard segmentation was measured by calculating the average Dice similarity (DSC), Jaccard (JI) and True positive rate (TPR) for each number of atlases. These similarity indices were compared for the different number of atlases using an equivalence trial and for the two label fusion groups using an independent sample-t test. DSC’s and JI’s were highest when using nine atlases with both STAPLE (average DSC = 0,532; JI = 0,369) and Patch (average DSC = 0,530; JI = 0,370). When comparing both label fusion algorithms using 9 atlases for both, DSC and JI values were not significantly different. However, significantly higher TPR values were achieved in favour of STAPLE (p < 0,001). When fewer than four atlases were used, STAPLE produced significantly lower DSC, JI and TPR values than did Patch (p = 0,0048). Using 9 atlases with STAPLE label fusion resulted in the most accurate BP autosegmentations (average DSC = 0,532; JI = 0,369 and TPR = 0,760). Only when using fewer than four atlases did the Patch label fusion results in a significantly more accurate autosegmentation than STAPLE.

25 August 2008 in The Anatomical Record
Verified
Journal Article
Open access
PDF file
THTom Van Hoof
Tom Van Hoof
GGGermano T. Gomes
Germano T. Gomes
EAEmmanuel Audenaert
Emmanuel Audenaert
KVKoenraad Verstraete
Koenraad Verstraete
IKIngrid Kerckaert
Ingrid Kerckaert
KDKatharina D'HErde
Katharina D'HErde
The aim of the present study was to develop a method for three‐dimensional (3D) reconstruction of the brachial plexus to study its morphology and to calculate strain and displacement in relation to changed nerve position. The brachial plexus was finely dissected and injected with contrast medium and leaden markers were implanted into the nerves at predefined places. A reverse shoulder prosthesis was inserted in a cadaveric specimen what induced positional change in the upper limb nerves. Computed tomography (CT) was performed before and after this surgical intervention. The computer assisted image processing package Mimics® was used to reconstruct the pre‐ and postoperative brachial plexus in 3D. The results show that the current interactive model is a realistic and detailed representation of the specimen used, which allows 3D study of the brachial plexus in different configurations. The model estimated strains up to 15.3% and 19.3% for the lateral and the medial root of the median nerve as a consequence of placing a reverse shoulder prosthesis. Furthermore, the model succeeded in calculating the displacement of the brachial plexus by tracking each implanted lead marker. The presented brachial plexus 3D model currently can be used in vitro for cadaver biomechanical analyses of nerve movement to improve diagnosis and treatment of peripheral neuropathies. The model can also be applied to study the exact location of the plexus in unusual upper limb positions like during axillary radiation therapy and it is a potential tool to optimize the approaches of brachial plexus anesthetic blocks. Anat Rec, 291:1173‐1185, 2008.

26 May 2017 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
PDPieter Deseyne
Pieter Deseyne
BSBruno Speleers
Bruno Speleers
WNWilfried De Neve
Wilfried De Neve
BBBert Boute
Bert Boute
LPLeen Paelinck
Leen Paelinck
LVLiv Veldeman
Liv Veldeman
Prone whole breast irradiation (WBI) leads to reduced heart and lung doses in breast cancer patients receiving adjuvant radiotherapy. In this feasibility trial, we investigated the prone position for whole breast + lymph node irradiation (WB + LNI). A new support device was developed for optimal target coverage, on which patients are positioned in a position resembling a phase from the crawl swimming technique (prone crawl position). Five left sided breast cancer patients were included and simulated in supine and prone position. For each patient, a treatment plan was made in prone and supine position for WB + LNI to the whole axilla and the unoperated part of the axilla. Patients served as their own controls for comparing dosimetry of target volumes and organs at risk (OAR) in prone versus in supine position. Target volume coverage differed only slightly between prone and supine position. Doses were significantly reduced (P < 0.05) in prone position for ipsilateral lung (Dmean, D2, V5, V10, V20, V30), contralateral lung (Dmean, D2), contralateral breast (Dmean, D2 and for total axillary WB + LNI also V5), thyroid (Dmean, D2, V5, V10, V20, V30), oesophagus (Dmean and for partial axillary WB + LNI also D2 and V5), skin (D2 and for partial axillary WB + LNI V105 and V107). There were no significant differences for heart and humeral head doses. Prone crawl position in WB + LNI allows for good breast and nodal target coverage with better sparing of ipsilateral lung, thyroid, contralateral breast, contralateral lung and oesophagus when compared to supine position. There is no difference in heart and humeral head doses. No trial registration was performed because there were no therapeutic interventions.

19 November 2021 in Medicina
Verified
Journal Article
Open access
PDF file
GNGianfranco Natale
Gianfranco Natale
Michael E. J. StouthandelMichael E. J. Stouthandel
Michael E. J. Stouthandel
THTom Van Hoof
Tom Van Hoof
GBGuido Bocci
Guido Bocci
Breast cancer is one of the most important causes of premature mortality among women and it is one of the most frequently diagnosed tumours worldwide. For this reason, routine screening for prevention and early diagnosis is important for the quality of life of patients. Breast cancer cells can enter blood and lymphatic capillaries, then metastasizing to the regional lymph nodes in the axilla and to both visceral and non-visceral sites. Rather than at the primary site, they seem to enter the systemic circulation mainly through the sentinel lymph node and the biopsy of this indicator can influence the axillary dissection during the surgical approach to the pathology. Furthermore, secondary lymphoedema is another important issue for women following breast cancer surgical treatment or radiotherapy. Considering these fundamental aspects, the present article aims to describe new methodological approaches to assess the anatomy of the lymphatic network in the axillary region, as well as the molecular and physiological control of lymphatic vessel function, in order to understand how the lymphatic system contributes to breast cancer disease. Due to their clinical implications, the understanding of the molecular mechanisms governing lymph node metastasis in breast cancer are also examined. Beyond the investigation of breast lymphatic networks and lymphatic molecular mechanisms, the discovery of new effective anti-lymphangiogenic drugs for future clinical settings appears essential to support any future development in the treatment of breast cancer.

29 July 2014 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
APAnnemieke De Puysseleyr
Annemieke De Puysseleyr
JVJoris Van De Velde
Joris Van De Velde
BSBruno Speleers
Bruno Speleers
TVTom Vercauteren
Tom Vercauteren
AGAnneleen Goedgebeur
Anneleen Goedgebeur
POPiet Ost
Piet Ost
To report the dosimetric results and impact of volumetric arc therapy (VMAT) on temporary alopecia and hair-loss related quality of life (QOL) in whole brain radiotherapy (WBRT). The potential of VMAT-WBRT to reduce the dose to the hair follicles was assessed. A human cadaver was treated with both VMAT-WBRT and conventional opposed field (OF) WBRT, while the subcutaneously absorbed dose was measured by radiochromic films and calculated by the planning system. The impact of these dose reductions on temporary alopecia was examined in a prospective phase II trial, with the mean score of hair loss at 1 month after VMAT-WBRT (EORTC-QOL BN20) as a primary endpoint and delivering a dose of 20 Gy in 5 fractions. An interim analysis was planned after including 10 patients to rule out futility, defined as a mean score of hair loss exceeding 56.7. A secondary endpoint was the global alopecia areata severity score measured with the "Severity of Alopecia Tool" (SALT) with a scale of 0 (no hair loss) to 100 (complete alopecia). For VMAT-WBRT, the cadaver measurements demonstrated a dose reduction to the hair follicle volume of 20.5% on average and of 41.8% on the frontal-vertex-occipital medial axis as compared to OF-WBRT. In the phase II trial, a total of 10 patients were included before the trial was halted due to futility. The EORTC BN20 hair loss score following WBRT was 95 (SD 12.6). The average median dose to the hair follicle volume was 12.6 Gy (SD 0.9), corresponding to a 37% dose reduction compared to the prescribed dose. This resulted in a mean SALT-score of 75. Compared to OF-WBRT, VMAT-WBRT substantially reduces hair follicle dose. These dose reductions could not be related to an improved QOL or SALT score.

19 August 2015 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
ACAn De Crop
An De Crop
PSPeter V. Smeets
Peter V. Smeets
THTom Van Hoof
Tom Van Hoof
MVMerel Vergauwen
Merel Vergauwen
TDTom Dewaele
Tom Dewaele
KBKlaus Bacher Klaus Bacher
Klaus Bacher Klaus Bacher
The first aim of this study was to evaluate the correlation between clinical and physical-technical image quality applied to different strengths of iterative reconstruction in chest CT images using Thiel cadaver acquisitions and Catphan images. The second aim was to determine the potential dose reduction of iterative reconstruction compared to conventional filtered back projection based on different clinical and physical-technical image quality parameters. Clinical image quality was assessed using three Thiel embalmed human cadavers. A Catphan phantom was used to assess physical-technical image quality parameters such as noise, contrast-detail and contrast-to-noise ratio (CNR). Both Catphan and chest Thiel CT images were acquired on a multislice CT scanner at 120 kVp and 0.9 pitch. Six different refmAs settings were applied (12, 30, 60, 90, 120 and 150refmAs) and each scan was reconstructed using filtered back projection (FBP) and iterative reconstruction (SAFIRE) algorithms (1,3 and 5 strengths) using a sharp kernel, resulting in 24 image series. Four radiologists assessed the clinical image quality, using a visual grading analysis (VGA) technique based on the European Quality Criteria for Chest CT. Correlation coefficients between clinical and physical-technical image quality varied from 0.88 to 0.92, depending on the selected physical-technical parameter. Depending on the strength of SAFIRE, the potential dose reduction based on noise, CNR and the inverse image quality figure (IQFinv) varied from 14.0 to 67.8 %, 16.0 to 71.5 % and 22.7 to 50.6 % respectively. Potential dose reduction based on clinical image quality varied from 27 to 37.4 %, depending on the strength of SAFIRE. Our results demonstrate that noise assessments in a uniform phantom overestimate the potential dose reduction for the SAFIRE IR algorithm. Since the IQFinv based dose reduction is quite consistent with the clinical based dose reduction, an optimised contrast-detail phantom could improve the use of contrast-detail analysis for image quality assessment in chest CT imaging. In conclusion, one should be cautious to evaluate the performance of CT equipment taking into account only physical-technical parameters as noise and CNR, as this might give an incomplete representation of the actual clinical image quality performance.