Timothy M. Cook

Timothy M. Cook

Top Cited Scholar 2026
Auto-generated profile, based on publicly available information

Timothy M. Cook

Department of Anaesthesia Royal United Hospitals Bath NHS Foundations Trust Bath UK

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2011 in British Journal of Anaesthesia
Verified
Journal Article
Open access
PDF file
TCT. M. Cook
T. M. Cook
NWN. Woodall
N. Woodall
CFC. Frerk
C. Frerk
This project was devised to estimate the incidence of major complications of airway management during anaesthesia in the UK and to study these events. Reports of major airway management complications during anaesthesia (death, brain damage, emergency surgical airway, unanticipated intensive care unit admission) were collected from all National Health Service hospitals for 1 yr. An expert panel assessed inclusion criteria, outcome, and airway management. A matched concurrent census estimated a denominator of 2.9 million general anaesthetics annually. Of 184 reports meeting inclusion criteria, 133 related to general anaesthesia: 46 events per million general anaesthetics [95% confidence interval (CI) 38–54] or one per 22 000 (95% CI 1 per 26–18 000). Anaesthesia events led to 16 deaths and three episodes of persistent brain damage: a mortality rate of 5.6 per million general anaesthetics (95% CI 2.8–8.3): one per 180 000 (95% CI 1 per 352–120 000). These estimates assume that all such cases were captured. Rates of death and brain damage for different airway devices (facemask, supraglottic airway, tracheal tube) varied little. Airway management was considered good in 19% of assessable anaesthesia cases. Elements of care were judged poor in three-quarters: in only three deaths was airway management considered exclusively good. Although these data suggest the incidence of death and brain damage from airway management during general anaesthesia is low, statistical analysis of the distribution of reports suggests as few as 25% of relevant incidents may have been reported. It therefore provides an indication of the lower limit for incidence of such complications. The review of airway management indicates that in a majority of cases, there is ‘room for improvement’.

29 March 2011 in British Journal of Anaesthesia
Verified
Journal Article
Open access
PDF file
TCT. M. Cook
T. M. Cook
NWN. Woodall
N. Woodall
JHJ. Harper
J. Harper
JBJ. Benger
J. Benger
The Fourth National Audit Project of the Royal College of Anaesthetists and Difficult Airway Society (NAP4) was designed to identify and study serious airway complications occurring during anaesthesia, in intensive care unit (ICU) and the emergency department (ED). Reports of major complications of airway management (death, brain damage, emergency surgical airway, unanticipated ICU admission, prolonged ICU stay) were collected from all National Health Service hospitals over a period of 1 yr. An expert panel reviewed inclusion criteria, outcome, and airway management. A total of 184 events met inclusion criteria: 36 in ICU and 15 in the ED. In ICU, 61% of events led to death or persistent neurological injury, and 31% in the ED. Airway events in ICU and the ED were more likely than those during anaesthesia to occur out-of-hours, be managed by doctors with less anaesthetic experience and lead to permanent harm. Failure to use capnography contributed to 74% of cases of death or persistent neurological injury. At least one in four major airway events in a hospital are likely to occur in ICU or the ED. The outcome of these events is particularly adverse. Analysis of the cases has identified repeated gaps in care that include: poor identification of at-risk patients, poor or incomplete planning, inadequate provision of skilled staff and equipment to manage these events successfully, delayed recognition of events, and failed rescue due to lack of or failure of interpretation of capnography. The project findings suggest avoidable deaths due to airway complications occur in ICU and the ED.

12 January 2009 in British Journal of Anaesthesia
Verified
Journal Article
Open access
PDF file
TCT. M. Cook
T. M. Cook
DCD. Counsell
D. Counsell
JWJ. A. W. Wildsmith
J. A. W. Wildsmith
Serious complications of central neuraxial block (CNB) are rare. Limited information on their incidence and impact impedes clinical decision-making and patient consent. The Royal College of Anaesthetists Third National Audit Project was designed to inform this situation. A 2 week national census estimated the number of CNB procedures performed annually in the UK National Health Service. All major complications of CNBs performed over 1 yr (vertebral canal abscess or haematoma, meningitis, nerve injury, spinal cord ischaemia, fatal cardiovascular collapse, and wrong route errors) were reported. Each case was reviewed by an expert panel to assess causation, severity, and outcome. ‘Permanent’ injury was defined as symptoms persisting for more than 6 months. Efforts were made to validate denominator (procedures performed) and numerator (complications) data through national databases. The census phase produced a denominator of 707 455 CNB. Eighty-four major complications were reported, of which 52 met the inclusion criteria at the time they were reported. Data were interpreted ‘pessimistically’ and ‘optimistically’. ‘Pessimistically’ there were 30 permanent injuries and ‘optimistically’ 14. The incidence of permanent injury due to CNB (expressed per 100 000 cases) was ‘pessimistically’ 4.2 (95% confidence interval 2.9–6.1) and ‘optimistically’ 2.0 (1.1–3.3). ‘Pessimistically’ there were 13 deaths or paraplegias, ‘optimistically’ five. The incidence of paraplegia or death was ‘pessimistically’ 1.8 per 100 000 (1.0–3.1) and ‘optimistically’ 0.7 (0–1.6). Two-thirds of initially disabling injuries resolved fully. The data are reassuring and suggest that CNB has a low incidence of major complications, many of which resolve within 6 months.

27 March 2020 in Anaesthesia
Verified
Journal Article
Open access
PDF file
TCT. M. Cook
T. M. Cook
KEK. El‐Boghdadly
K. El‐Boghdadly
BMB. McGuire
B. McGuire
AMA. F. McNarry
A. F. McNarry
APA. Patel
A. Patel
AHA. Higgs
A. Higgs
Summary: Severe acute respiratory syndrome‐corona virus‐2, which causes coronavirus disease 2019 (COVID‐19), is highly contagious. Airway management of patients with COVID‐19 is high risk to staff and patients. We aimed to develop principles for airway management of patients with COVID‐19 to encourage safe, accurate and swift performance. This consensus statement has been brought together at short notice to advise on airway management for patients with COVID‐19, drawing on published literature and immediately available information from clinicians and experts. Recommendations on the prevention of contamination of healthcare workers, the choice of staff involved in airway management, the training required and the selection of equipment are discussed. The fundamental principles of airway management in these settings are described for: emergency tracheal intubation; predicted or unexpected difficult tracheal intubation; cardiac arrest; anaesthetic care; and tracheal extubation. We provide figures to support clinicians in safe airway management of patients with COVID‐19. The advice in this document is designed to be adapted in line with local workplace policies.


1 July 2018 in British Journal of Anaesthesia
Verified
Journal Article
Closed access
NHN.J.N. Harper
N.J.N. Harper
TCT.M. Cook
T.M. Cook
TGT. Garcez
T. Garcez
LFL. Farmer
L. Farmer
KFK. Floss
K. Floss
NMN. McGuire
N. McGuire